718 research outputs found
Fifteen years of XMM-Newton and Chandra monitoring of Sgr A*: Evidence for a recent increase in the bright flaring rate
We present a study of the X-ray flaring activity of Sgr A* during all the 150
XMM-Newton and Chandra observations pointed at the Milky Way center over the
last 15 years. This includes the latest XMM-Newton and Chandra campaigns
devoted to monitoring the closest approach of the very red Br-Gamma emitting
object called G2. The entire dataset analysed extends from September 1999
through November 2014. We employed a Bayesian block analysis to investigate any
possible variations in the characteristics (frequency, energetics, peak
intensity, duration) of the flaring events that Sgr A* has exhibited since
their discovery in 2001. We observe that the total bright-or-very bright flare
luminosity of Sgr A* increased between 2013-2014 by a factor of 2-3 (~3.5 sigma
significance). We also observe an increase (~99.9% significance) from
0.27+-0.04 to 2.5+-1.0 day^-1 of the bright-or-very bright flaring rate of Sgr
A*, starting in late summer 2014, which happens to be about six months after
G2's peri-center passage. This might indicate that clustering is a general
property of bright flares and that it is associated with a stationary noise
process producing flares not uniformly distributed in time (similar to what is
observed in other quiescent black holes). If so, the variation in flaring
properties would be revealed only now because of the increased monitoring
frequency. Alternatively, this may be the first sign of an excess accretion
activity induced by the close passage of G2. More observations are necessary to
distinguish between these two hypotheses.Comment: Accepted for publication in MNRA
Fertilizer type influences tomato yield and soil N2O emissions
Improvements in crop management for a more sustainable agriculture are fundamental to reduce environmental impacts of cropland and to mitigate effects on global climate change. In this study three fertilization types – ammonium nitrate (control); mineral fertilizer added with a nitrification inhibitor (3,4-dimethylpyrazole phosphate (DMPP)), and an organo-mineral fertilizer (OM) – were tested on a tomato crop in order to evaluate effects both on crop production and soil N2O emissions. Plants grown under OM fertilization had a greater relative growth rate compared to mineral fertilization, due to a higher net assimilation rate, which was related to a greater light interception rather than to a higher photosynthetic efficiency. OM fertilization determined the highest fruit production and lower soil N2O fluxes compared to NH4NO3, although the lowest soil N2O fluxes were found in response to mineral fertilizer added with a nitrification inhibitor. It can be concluded that organo-mineral fertilizer is a better nutrient source compared to mineral fertilizers able to improve crop yield and to mitigate soil N2O emission
NuSTAR + XMM-Newton monitoring of the neutron star transient AX J1745.6-2901
AX J1745.6-2901 is a high-inclination (eclipsing) transient neutron star (NS)
Low Mass X-ray Binary (LMXB) showcasing intense ionised Fe K absorption. We
present here the analysis of 11 XMM-Newton and 15 NuSTAR new data-sets
(obtained between 2013-2016), therefore tripling the number of observations of
AX J1745.6-2901 in outburst. Thanks to simultaneous XMM-Newton and NuSTAR
spectra, we greatly improve on the fitting of the X-ray continuum. During the
soft state the emission can be described by a disk black body (
keV and inner disc radius km), plus hot ( keV)
black body radiation with a small emitting radius ( km)
likely associated with the boundary layer or NS surface, plus a faint
Comptonisation component. Imprinted on the spectra are clear absorption
features created by both neutral and ionised matter. Additionally, positive
residuals suggestive of an emission Fe K disc line and consistent with
relativistic ionised reflection are present during the soft state, while such
residuals are not significant during the hard state. The hard state spectra are
characterised by a hard () power law, showing no evidence
for a high energy cut off ( keV) and implying a small optical
depth (). The new observations confirm the previously witnessed trend
of exhibiting strong Fe K absorption in the soft state, that significantly
weakens during the hard state. Optical (GROND) and radio (GMRT) observations
suggest for AX J1745.6-2901 a standard broad band SED as typically observed in
accreting neutron stars.Comment: Accepted for publication in MNRA
Epidemiology of skin and soft tissue pathogens circulating in Liguria in 2011
This study was conduced during March-May 2011 with the collaboration of 4 clinical microbiology laboratories evenly distibuited across the Ligurian area to identify the most frequent pahogens isolates from skin and soft tissue infections and to evaluate their antibiotic susceptibility patterns. Overall, 213 consecutive, non duplicate strains were collected and sent to the coordinating laboratory.The most rappresented pathogens were: S. aureus (35.7%), P. aeruginosa (14%), E. coli (12.7%), Staphylococcus coaugulase negative (6.6%) and Enterococcus spp. (4.7%). The data indicate an increase of Gram negative compared to previous years, S. aureus remains the most common pathogen.The methicillin resistance in S. aureus was 43.4% and no one Enterococcus spp. resistant to vancomicin was found
Prototyping of petalets for the Phase-II Upgrade of the silicon strip tracking detector of the ATLAS Experiment
In the high luminosity era of the Large Hadron Collider, the HL-LHC, the
instantaneous luminosity is expected to reach unprecedented values, resulting
in about 200 proton-proton interactions in a typical bunch crossing. To cope
with the resultant increase in occupancy, bandwidth and radiation damage, the
ATLAS Inner Detector will be replaced by an all-silicon system, the Inner
Tracker (ITk). The ITk consists of a silicon pixel and a strip detector and
exploits the concept of modularity. Prototyping and testing of various strip
detector components has been carried out. This paper presents the developments
and results obtained with reduced-size structures equivalent to those foreseen
to be used in the forward region of the silicon strip detector. Referred to as
petalets, these structures are built around a composite sandwich with embedded
cooling pipes and electrical tapes for routing the signals and power. Detector
modules built using electronic flex boards and silicon strip sensors are glued
on both the front and back side surfaces of the carbon structure. Details are
given on the assembly, testing and evaluation of several petalets. Measurement
results of both mechanical and electrical quantities are shown. Moreover, an
outlook is given for improved prototyping plans for large structures.Comment: 22 pages for submission for Journal of Instrumentatio
Identification of a new p53/MDM2 inhibitor motif inspired by studies of chlorofusin
Previous studies on the natural product chlorofusin have shown that the full peptide and azaphilone structure are required for inhibition of the interaction between MDM2 and p53. In the current work, we utilized the cyclic peptide as a template and introduced an azidonorvaline amino acid in place of the ornithine/azaphilone of the natural product and carried out click chemistry with the resulting peptide. From this small library the first ever non-azaphilone containing chlorofusin analogue with MDM2/p53 activity was identified. Further studies then suggested that the simple structure of the Fmoc-norvaline amino acid that had undergone a click reaction was also able to inhibit MDM2/p53 interaction. This is an example where studies of a natural product have led to the serendipitous identification of a new small molecule inhibitor of a protein-protein interaction
Connectivity-based parcellation of the thalamus explains specific cognitive and behavioural symptoms in patients with bilateral thalamic infarct
A novel approach based on diffusion tractography was used here to characterise the cortico-thalamic connectivity in two patients, both presenting with an isolated bilateral infarct in the thalamus, but exhibiting partially different cognitive and behavioural profiles. Both patients (G.P. and R.F.) had a pervasive deficit in episodic memory, but only one of them (R.F.) suffered also from a dysexecutive syndrome. Both patients had an MRI scan at 3T, including a T1-weighted volume. Their lesions were manually segmented. T1-volumes were normalised to standard space, and the same transformations were applied to the lesion masks. Nineteen healthy controls underwent a diffusion-tensor imaging (DTI) scan. Their DTI data were normalised to standard space and averaged. An atlas of Brodmann areas was used to parcellate the prefrontal cortex. Probabilistic tractography was used to assess the probability of connection between each voxel of the thalamus and a set of prefrontal areas. The resulting map of corticothalamic connections was superimposed onto the patients' lesion masks, to assess whether the location of the thalamic lesions in R.F. (but not in G. P.) implied connections with prefrontal areas involved in dysexecutive syndromes. In G.P., the lesion fell within areas of the thalamus poorly connected with prefrontal areas, showing only a modest probability of connection with the anterior cingulate cortex (ACC). Conversely, R.F.'s lesion fell within thalamic areas extensively connected with the ACC bilaterally, with the right dorsolateral prefrontal cortex, and with the left supplementary motor area. Despite a similar, bilateral involvement of the thalamus, the use of connectivity-based segmentation clarified that R.F.'s lesions only were located within nuclei highly connected with the prefrontal cortical areas, thus explaining the patient's frontal syndrome. This study confirms that DTI tractography is a useful tool to examine in vivo the effect of focal lesions on interconnectivity brain patterns
Epidemiological study of pathogens isolated from blood in Liguria during 2011
Objectives. An epidemiological study addressed to identify the most represented pathogens isolated from blood and to evaluate their antibiotic susceptibility patterns, was conducted. Methods. Five clinical microbiology laboratories, homogenously distributed in Liguria, were required to collected all consecutive non-duplicates strains isolated from blood cultures during March 2011 to May 2011. the strains were sent to the reference laboratory (Section of Microbiology, DISC, University of Genoa, Italy). Results. A total of 159 microorganisms were enrolled, including 81 Gram positive, 69 Gram negative and 9 fungi.The most represented pathogens were: Escherichia coli (35), Staphylococcus aureus (26), S. epidermidis (20), S. hominis (10). Samples were collected mainly from medicine (59 isolates).Among the staphylococci, the most active molecules were: vancomycin (100% of susceptible strains), teicoplanin (93.4%), trimethoprim-sulfamethoxazole (83.8%) and tobramycin (61.6%). Enterococci showed rates of resistance to vancomycin of 25%. Enterobacteriaceae exhibited resistance to ampicillin (76.9%), ceftriaxone (44.4%), ciprofloxacin (43.3%), trimethoprim-sulfamethoxazole (36.6%) and ceftazidime (32.2%). Conclusions. The data show a higher incidence of Gram positive (51%) in comparison to Gram negative (43.4%). Gram-positive strains showed a high resistance level to fluoroquinolones (92.3%) while Gram-negative resulted resistant to ceftriaxone (44.4%) and fluoroquinolone (43.3%)
X-ray harmonic comb from relativistic electron spikes
X-ray devices are far superior to optical ones for providing nanometre
spatial and attosecond temporal resolutions. Such resolution is indispensable
in biology, medicine, physics, material sciences, and their applications. A
bright ultrafast coherent X-ray source is highly desirable, for example, for
the diffractive imaging of individual large molecules, viruses, or cells. Here
we demonstrate experimentally a new compact X-ray source involving high-order
harmonics produced by a relativistic-irradiance femtosecond laser in a gas
target. In our first implementation using a 9 Terawatt laser, coherent soft
X-rays are emitted with a comb-like spectrum reaching the 'water window' range.
The generation mechanism is robust being based on phenomena inherent in
relativistic laser plasmas: self-focusing, nonlinear wave generation
accompanied by electron density singularities, and collective radiation by a
compact electric charge. The formation of singularities (electron density
spikes) is described by the elegant mathematical catastrophe theory, which
explains sudden changes in various complex systems, from physics to social
sciences. The new X-ray source has advantageous scalings, as the maximum
harmonic order is proportional to the cube of the laser amplitude enhanced by
relativistic self-focusing in plasma. This allows straightforward extension of
the coherent X-ray generation to the keV and tens of keV spectral regions. The
implemented X-ray source is remarkably easily accessible: the requirements for
the laser can be met in a university-scale laboratory, the gas jet is a
replenishable debris-free target, and the harmonics emanate directly from the
gas jet without additional devices. Our results open the way to a compact
coherent ultrashort brilliant X-ray source with single shot and high-repetition
rate capabilities, suitable for numerous applications and diagnostics in many
research fields
Respiratory modulation of oscillometric cuff pressure pulses and Korotkoff sounds during clinical blood pressure measurement in healthy adults
BACKGROUND:
Accurate blood pressure (BP) measurement depends on the reliability of oscillometric cuff pressure pulses (OscP) and Korotkoff sounds (KorS) for automated oscillometric and manual techniques. It has been widely accepted that respiration is one of the main factors affecting BP measurement. However, little is known about how respiration affects the signals from which BP measurement is obtained. The aim was to quantify the modulation effect of respiration on oscillometric pulses and KorS during clinical BP measurement.
METHODS:
Systolic and diastolic BPs were measured manually from 40 healthy subjects (from 23 to 65 years old) under normal and regular deep breathing. The following signals were digitally recorded during linear cuff deflation: chest motion from a magnetometer to obtain reference respiration, cuff pressure from an electronic pressure sensor to derive OscP, and KorS from a digital stethoscope. The effects of respiration on both OscP and KorS were determined from changes in their amplitude associated with respiration between systole and diastole. These changes were normalized to the mean signal amplitude of OscP and KorS to derive the respiratory modulation depth. Reference respiration frequency, and the frequencies derived from the amplitude modulation of OscP and KorS were also calculated and compared.
RESULTS:
Respiratory modulation depth was 14 and 40 % for OscP and KorS respectively under normal breathing condition, with significant increases (both p 0.05) during deep breathing, and for the oscillometric signal during normal breathing (p > 0.05).
CONCLUSIONS:
Our study confirmed and quantified the respiratory modulation effect on the oscillometric pulses and KorS during clinical BP measurement, with increased modulation depth under regular deeper breathing
- …