1,083 research outputs found
Results for the response function determination of the Compact Neutron Spectrometer
The Compact Neutron Spectrometer (CNS) is a Joint European Torus (JET)
Enhancement Project, designed for fusion diagnostics in different plasma
scenarios. The CNS is based on a liquid scintillator (BC501A) which allows good
discrimination between neutron and gamma radiation. Neutron spectrometry with a
BC501A spectrometer requires the use of a reliable, fully characterized
detector. The determination of the response matrix was carried out at the Ion
Accelerator Facility (PIAF) of the Physikalisch-Technische Bundesanstalt (PTB).
This facility provides several monoenergetic beams (2.5, 8, 10, 12 and 14 MeV)
and a 'white field'(Emax ~17 MeV), which allows for a full characterization of
the spectrometer in the region of interest (from ~1.5 MeV to ~17 MeV. The
energy of the incoming neutrons was determined by the time of flight method
(TOF), with time resolution in the order of 1 ns. To check the response matrix,
the measured pulse height spectra were unfolded with the code MAXED and the
resulting energy distributions were compared with those obtained from TOF. The
CNS project required modification of the PTB BC501A spectrometer design, to
replace an analog data acquisition system (NIM modules) with a digital system
developed by the 'Ente per le Nuove tecnologie, l'Energia e l'Ambiente' (ENEA).
Results for the new digital system were evaluated using new software developed
specifically for this project.Comment: Proceedings of FNDA 201
Atomic oxygen studies on polymers
The purpose was to study the effects of atomic oxygen on the erosion of polymer based materials. The development of an atomic oxygen neutral beam facility using a SURFATRON surface wave launcher that can produce beam energies between 2 and 3 eV at flux levels as high as approx. 10 to the 17th power atoms/cm (2)-sec is described. Thin film dielectric materials were studied to determine recession rates and and reaction efficiencies as a function of incident beam energy and fluence. Accelerated testing was also accomplished and the values of reaction efficiency compared to available space flight data. Electron microscope photomicrographs of the samples' surface morphology were compared to flight test specimens
Aoulef
Oasis du Tidikelt* situĂ©e Ă environ 170 kilomĂštres Ă lâouest dâIn-Salah* et Ă 42 kilomĂštres au nord-ouest dâAkabli*. Une piste relie aujourdâhui directement Aoulef Ă Reggan, ce qui permet la nouvelle intĂ©gration dâAoulef (1972) Ă la wilaya dâAdrar. SituĂ© en bordure du plateau du TademaĂŻt*, lâensemble dĂ©signĂ© globalement sous le toponyme dâAoulef est nĂ© de la construction de plusieurs fortins (appelĂ©s tantĂŽt Kasba, tantĂŽt Ksar/Ksour=qáčŁur) qui semblent ĂȘtre historiquement postĂ©rieurs Ă ceux dâA..
Aoulef
Oasis du Tidikelt* situĂ©e Ă environ 170 kilomĂštres Ă lâouest dâIn-Salah* et Ă 42 kilomĂštres au nord-ouest dâAkabli*. Une piste relie aujourdâhui directement Aoulef Ă Reggan, ce qui permet la nouvelle intĂ©gration dâAoulef (1972) Ă la wilaya dâAdrar. SituĂ© en bordure du plateau du TademaĂŻt*, lâensemble dĂ©signĂ© globalement sous le toponyme dâAoulef est nĂ© de la construction de plusieurs fortins (appelĂ©s tantĂŽt Kasba, tantĂŽt Ksar/Ksour=qáčŁur) qui semblent ĂȘtre historiquement postĂ©rieurs Ă ceux dâA..
Imaging Gold Nanoparticles in Living Cells Environments using Heterodyne Digital Holographic Microscopy
This paper describes an imaging microscopic technique based on heterodyne
digital holography where subwavelength-sized gold colloids can be imaged in
cell environment. Surface cellular receptors of 3T3 mouse fibroblasts are
labeled with 40 nm gold nanoparticles, and the biological specimen is imaged in
a total internal reflection configuration with holographic microscopy. Due to a
higher scattering efficiency of the gold nanoparticles versus that of cellular
structures, accurate localization of a gold marker is obtained within a 3D
mapping of the entire sample's scattered field, with a lateral precision of 5
nm and 100 nm in the x,y and in the z directions respectively, demonstrating
the ability of holographic microscopy to locate nanoparticles in living cells
environments
Tuning a Schottky barrier in a photoexcited topological insulator with transient Dirac cone electron-hole asymmetry
The advent of Dirac materials has made it possible to realize two dimensional
gases of relativistic fermions with unprecedented transport properties in
condensed matter. Their photoconductive control with ultrafast light pulses is
opening new perspectives for the transmission of current and information. Here
we show that the interplay of surface and bulk transient carrier dynamics in a
photoexcited topological insulator can control an essential parameter for
photoconductivity - the balance between excess electrons and holes in the Dirac
cone. This can result in a strongly out of equilibrium gas of hot relativistic
fermions, characterized by a surprisingly long lifetime of more than 50 ps, and
a simultaneous transient shift of chemical potential by as much as 100 meV. The
unique properties of this transient Dirac cone make it possible to tune with
ultrafast light pulses a relativistic nanoscale Schottky barrier, in a way that
is impossible with conventional optoelectronic materials.Comment: Nature Communications, in press (12 pages, 6 figures
Age at menarche in Canada: results from the National Longitudinal Survey of Children & Youth
<p>Abstract</p> <p>Background</p> <p>Given the downward trend in age at menarche and its implications for the reproductive health and wellbeing of women, little is known about menarcheal age in Canada. Most Canadian studies are only representative of specific populations. The present study, therefore, aims to assess the distribution of age at menarche for Canadian girls and explore its variation across socio-economic and demographic factors.</p> <p>Methods</p> <p>The analysis of the study was based on all female respondents aged 14 to 17 years during Cycle 4 (2000/2001) of the National Longitudinal Survey of Children & Youth (NLSCY). The main outcome was age at menarche assessed as the month and year of the occurrence of the first menstrual cycle. Kaplan Meier was used to estimate the mean and median of age at menarche. Chi-square test was used to assess the differences in early, average and later maturers across the different levels of socio-economic and demographic variables. Bootstrapping was performed to account for the complex sampling design.</p> <p>Results</p> <p>The total number of girls analyzed in this study was 1,403 weighted to represent 601,911 Canadian girls. The estimated mean and median of age at menarche was 12.72 years (standard deviation = 1.05) and 12.67 years, respectively. The proportions of early (< 11.53 years), average (â„11.53 years and â€13.91 years) and late maturers (> 13.91 years) were 14.6% (95% confidence interval (CI): 11.92-17.35), 68.0% (95% CI: 63.82-72.17) and 17.4% (95% CI: 14.10-20.63), respectively. Variations across the menarcheal groups were statistically significant for the province of residence, household income and family type.</p> <p>Conclusion</p> <p>The findings of the study pave the way for future Canadian research. More studies are warranted to understand menarcheal age in terms of its variation across the provinces, the secular trend over time and its potential predictors.</p
The prominent role of the heaviest fragment in multifragmentation and phase transition for hot nuclei
The role played by the heaviest fragment in partitions of multifragmenting
hot nuclei is emphasized. Its size/charge distribution (mean value,
fluctuations and shape) gives information on properties of fragmenting nuclei
and on the associated phase transition.Comment: 11 pages, Proceedings of IWND09, August 23-25, Shanghai (China
Lower limb biomechanics during drop jump landing in individuals with chronic ankle instability
ABSTRACT
Context: Individuals with chronic ankle instability (CAI) exhibit impaired lower limb biomechanics during unilateral drop jump landing on a flat surface. However, lower limb biomechanical adaptations during unilateral drop jump landing on more challenging surfaces such as unstable or inclined are yet to be described.
Objective: Determine how unilateral drop jump landing surfaces (flat, unstable and inclined) influence lower limb EMG, kinematics and kinetics in individuals with CAI.
Design: Descriptive laboratory study.
Setting: Biomechanics laboratory.
Patients or Other Participants: Twenty-two young adults with CAI
Interventions: Participants completed five trials of unilateral drop jump landing from a 46 cm height platform on flat (DROP), unstable (FOAM) and laterally inclined (WEDGE) surfaces.
Main outcome measure(s): EMG of gluteus medius, vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were recorded. Knee and ankle angles and moments were calculated using a three-dimensional motion analysis system and a force plate. Biomechanical variables were compared between tasks using one-dimensional statistical nonparametric mapping.
Results: During DROP, greater ankle dorsiflexion angles, knee extension moments and vastus lateralis muscle activity (FOAM only) were observed compared to FOAM and WEDGE. Greater ankle inversion angles were observed during FOAM and WEDGE compared to DROP. Peroneus longus muscle activity was greater during DROP compared to FOAM. During FOAM, greater ankle inversion and knee extension angles, ankle inversion and internal rotation moments as well as smaller peroneus longus muscle activity were observed compared to WEDGE.
Conclusions: The greater ankle inversion and plantarflexion angles as well as the lack of increase in peroneus longus muscle activation during FOAM and WEDGE could increase the risk of recurrent LAS in individuals with CAI. The results of this study improve our understanding of lower limb biomechanics changes when landing on more challenging surfaces and will help clinicians better targeting deficits associated with CAI during rehabilitation
- âŠ