201 research outputs found
Transcatheter aortic valve replacement in obese patients: procedural vascular complications with the trans-femoral and trans-carotid access routes
Obesity; Transcarotid; TransfemoralObesidad; TranscarotĂdea; TransfemoralObesitat; Transcaròtida; TransfemoralOBJECTIVES
Obesity may increase the risk of vascular complications in transfemoral (TF) transcatheter aortic valve replacement (TAVR) procedures. The transcarotid (TC) approach has recently emerged as an alternative access in TAVR. We sought to compare vascular complications and early clinical outcomes in obese patients undergoing TAVR either by TF or TC vascular access.
METHODS
Multicentre registry including obese patients undergoing TF- or TC-TAVR in 15 tertiary centres. All patients received newer-generation transcatheter heart valves. For patients exhibiting unfavourable ileo-femoral anatomic characteristics, the TC approach was favoured in 3 centres with experience with it. A propensity score analysis was performed for overcoming unbalanced baseline covariates. The primary end point was the occurrence of in-hospital vascular complications (Valve Academic Research Consortium-2 criteria).
RESULTS
A total of 539 patients were included, 454 (84.2%) and 85 (15.8%) had a TF and TC access, respectively. In the propensity-adjusted cohort (TF: 442 patients; TC: 85 patients), both baseline and procedural valve-related characteristics were well-balanced between groups. A significant decrease in vascular complications was observed in the TC group (3.5% vs 12% in the TF group, odds ratio: 0.26, 95% CI: 0.07–0.95, P = 0.037). There were no statistically significant differences between groups regarding in-hospital mortality (TC: 2.8%, TF: 1.5%), stroke (TC: 1.2%, TF: 0.4%) and life-threatening/major bleeding events (TC: 2.8%, TF: 3.8%).
CONCLUSIONS
In patients with obesity undergoing TAVR with newer-generation devices, the TC access was associated with a lower rate of vascular complications. Larger randomized studies are warranted to further assess the better approach for TAVR in obese patients
Advances in transcatheter mitral and tricuspid therapies
BACKGROUND: While rheumatic mitral stenosis has been effectively treated percutaneously for more than 20 years, mitral and tricuspid regurgitation treatment appear as a contemporary unmet need. The advent of transcatheter therapies offer new treatment options to often elderly and frail patients at high risk for open surgery. We aimed at providing an updated review of fast-growing domain of transcatheter mitral and tricuspid technology. MAIN BODY: We reviewed the existing literature on mitral and tricuspid transcatheter therapies. Mitraclip is becoming an established therapy for secondary mitral regurgitation in selected patients with disproportionately severe regurgitation associated with moderate left ventricle dysfunction. Evidence is less convincing for primary mitral regurgitation. Transcatheter mitral valve replacement is a promising emerging alternative to transcatheter repair, for secondary as well as primary mitral regurgitation. But further development is needed to improve delivery. Transcatheter tricuspid intervention arrives late after similar technologies have been developed for aortic and mitral valves and is currently at its infancy. This is likely due in part to previously under-recognized impact of tricuspid regurgitation on patient outcomes. Edge-to-edge repair is the most advanced transcatheter solution in development. Data on tricuspid annuloplasty and replacement is limited, and more research is warranted. CONCLUSION: The future appears bright for transcatheter mitral therapies, albeit their place in clinical practice is yet to be clearly defined. Tricuspid transcatheter therapies might address the unmet need of tricuspid regurgitation treatment
Structure of multidisciplinary heart teams, a survey based heart team study.
OBJECTIVES
Multidisciplinary approach is well established in various disciplines, with evidence highlighting improved patient outcomes. The objective of this survey was to determine the real world practice of heart teams across Europe.
METHODS
The survey was drafted after a consensus opinion from the authors. The survey was sent to cardiac surgeons and cardiologist identified through electronic search. The survey link and the information sheet were sent through email followed by survey completion reminders. The survey responses were cumulated and analysed.
RESULTS
Among 2188 invited clinicians, 220 clinicians from 26 countries took part in the survey (response rate 10%). The completion rate for the survey questions was 85%. 140 (64%) were cardiac surgeons and 80 (36%) were cardiologists. The heart team meeting frequency was weekly according to 104 (55%) respondents. This was conducted face to face according to 139 (73%) of the responses. Eighty seven (56%) of the respondents reported 10% - 20% of patients undergoing percutaneous coronary intervention (PCI) were discussed at the heart team meeting. Seventy nine (47%) respondents had ad hoc PCI institutional guidelines. Fifty four (32%) respondents reported an audit process for the heart team decisions.
CONCLUSIONS
This survey suggests that there is marked variability in the infra-structure and execution of heart teams in different institutions. The results of the survey suggest a need to formulate guidelines on composition and execution of heart teams which may result in an increase in transparency of decision-making within different institutions in reporting and comparing outcomes
Final 3-year clinical outcomes following transcatheter aortic valve implantation with a supra-annular self-expanding repositionable valve in a real-world setting: Results from the multicenter FORWARD study.
OBJECTIVES
The Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3-year clinical follow up of the FORWARD study.
BACKGROUND
Transcatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long-term clinical outcome data with the Evolut R platform are scarce.
METHODS
FORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart-Team assessment. TAVR was attempted in 1039 patients.
RESULTS
Mean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all-cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all-cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all-cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low.
CONCLUSIONS
The Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve-related adverse events were low
TAVI-PREP: A Deep Learning-Based Tool for Automated Measurements Extraction in TAVI Planning
ABSTRACT: Background: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to open-heart surgery for treating severe aortic stenosis. Despite its benefits, the risk of procedural complications necessitates careful preoperative planning. Methods: This study proposes a fully automated deep learning-based method, TAVI-PREP, for pre-TAVI planning, focusing on measurements extracted from computed tomography (CT) scans. The algorithm was trained on the public MM-WHS dataset and a small subset of private data. It uses MeshDeformNet for 3D surface mesh generation and a 3D Residual U-Net for landmark detection. TAVI-PREP is designed to extract 22 different measurements from the aortic valvular complex. A total of 200 CT-scans were analyzed, and automatic measurements were compared to the ones made manually by an expert cardiologist. A second cardiologist analyzed 115 scans to evaluate inter-operator variability. Results: High Pearson correlation coefficients between the expert and the algorithm were obtained for most parameters (0.90–0.97), except for left and right coronary height (0.8 and 0.72, respectively). Similarly, the mean absolute relative error was within 5% for most measurements, except for left and right coronary height (11.6% and 16.5%, respectively). A greater consensus was observed among experts than when compared to the automatic approach, with TAVI-PREP showing no discernable bias towards either the lower or higher ends of the measurement spectrum. Conclusions: TAVI-PREP provides reliable and time-efficient measurements of the aortic valvular complex that could aid clinicians in the preprocedural planning of TAVI procedures
- …