316 research outputs found
Postoperative complications and waiting time for surgical intervention after radiologically guided drainage of intraabdominal abscess in patients with Crohnâs disease.
Background
In patients with active Crohnâs disease (CD), treatment of intra-abdominal abscess usually comprises antibiotics and radiologically guided percutaneous drainage (PD) preceding surgery. The aim of this study was to investigate the risk of postoperative complications and identify the optimal time interval for surgical intervention after PD.
Methods
A multicentre, international, retrospective cohort study was carried out. Details of patients with diagnosis of CD who underwent ultrasonography- or CT-guided PD were retrieved from hospital records using international classification of disease (ICD-10) diagnosis code for CD combined with procedure code for PD. Clinical variables were retrieved and the following outcomes were measured: 30-day postoperative overall complications, intra-abdominal septic complications, unplanned intraoperative adverse events, surgical-site infections, sepsis and pathological postoperative ileus, in addition to abscess recurrence. Patients were categorized into three groups according to the length of the interval from PD to surgery (1â14 days, 15â30 days and more than 30 days) for comparison of outcomes.
Results
The cohort comprised 335 CD patients with PD followed by surgery. Median age was 33 (i.q.r. 24â44) years, 152 (45.4 per cent) were females, and median disease duration was 9 (i.q.r. 3.6â15) years. Overall, the 30-day postoperative complications rate was 32.2 per cent and the mortality rate was 1.5 per cent. After adjustment for co-variables, older age (odds ratio 1.03 (95 per cent c.i. 1.01 to 1.06), P < 0.012), residual abscess after PD (odds ratio 0.374 (95 per cent c.i. 0.19 to 0.74), P < 0.014), smoking (odds ratio 1.89 (95 per cent c.i. 1.01 to 3.53), P = 0.049) and low serum albumin concentration (odds ratio 0.921 (95 per cent c.i. 0.89 to 0.96), P < 0.001) were associated with higher rates of postoperative complications. A short waiting interval, less than 2 weeks after PD, was associated with a high incidence of abscess recurrence (odds ratio 0.59 (95 per cent c.i. 0.36 to 0.96), P = 0.042).
Conclusion
Smoking, low serum albumin concentration and older age were significantly associated with postoperative complications. An interval of at least 2 weeks after successful PD correlated with reduced risk of abscess recurrence.post-print664 K
Watchful Waiting After Radiological Guided Drainage of Intra-abdominal Abscess in Patients With Crohnâs Disease Might Be Associated With Increased Rates of Stoma Construction.
Background: Management of spontaneous intra-abdominal abscess (IAA) in patients with Crohnâs disease (CD) with radiologically guided percutaneous drainage (PD) was debated.
Methods: This is a secondary analysis from a multicenter, retrospective cohort study of all the patients with CD who underwent PD followed by surgery at 19 international tertiary centers.
Results: Seventeen patients (4.8%) who did not undergo surgery after PD were compared to those who had PD followed by surgical intervention 335/352 (95.2%). Patients who had PD without surgery were those with longer disease duration, more frequently had previous surgery for CD (laparotomies/laparoscopies), enteric fistula, on steroid treatment before and continue to have it after PD. Patients who had PD without subsequent surgical resection had a higher risk of stoma construction at later stages 8/17 (47.1%) versus 90/326 (27.6%) (P < .01). Patients with PD with no subsequent surgery had numerically higher rates of abscess recurrence 5/17 (29.4%) compared to those who had PD followed by surgery 45/335 (13.4%) the difference was not statistically significant (P = .07).
Conclusions: Even with the low number of patients enrolled in this study who had PD of IAA without subsequent surgery, the findings indicate a markedly worse prognosis in terms of recurrence, length of stay, readmission, and stoma construction. Watchful waiting after PD to treat patients with spontaneous IAA might be indicated in selected patients with poor health status or poor prognostic factors.post-print179 K
Maternal, Perinatal and Neonatal Outcomes of Triplet Pregnancies According to Chorionicity: A Systematic Review of the Literature and Meta-Analysis
Triplet pregnancies are rare events that affect approximately 93 in 100,000 deliveries in the world, especially due to the increased use of assisted reproductive techniques and older maternal age. Triplet pregnancies are associated with a higher risk of fetal and maternal morbidity and mortality compared to twins and singletons. Chorionicity has been proposed as a major determinant of perinatal and maternal outcomes in triplet pregnancies, although further evidence is needed to clarify the extent and real influence of this factor. Thus, the aim of this study was to conduct a systematic review of the literature and a meta-analysis of the maternal and perinatal outcomes of triplet pregnancies, evaluating how chorionicity may influence these results. A total of 46 studies with 43,653 triplet pregnancies and 128,145 live births were included. Among the main results of our study, we found a broad spectrum of fetal and maternal complications, especially in the group of monochorionic and dichorionic pregnancies. Risk of admission to NICU, respiratory distress, sepsis, necrotizing enterocolitis, perinatal and intrauterine mortality were all found to be higher in non-TCTA pregnancies than in TCTA pregnancies. To date, our meta-analysis includes the largest population sample and number of studies conducted in this field, evaluating a wide variety of outcome measures. The heterogeneity and retrospective design of the studies included in our research represent the main limitations of this review. More evidence is needed to fully assess outcome measures that could not be studied in this review due to scarcity of publications or insufficient sample size
COVID-19-related absence among surgeons: development of an international surgical workforce prediction model
Background:
During the initial COVID-19 outbreak up to 28.4 million elective operations were cancelled worldwide, in part owing to concerns that it would be unsustainable to maintain elective surgery capacity because of COVID-19-related surgeon absence. Although many hospitals are now recovering, surgical teams need strategies to prepare for future outbreaks. This study aimed to develop a framework to predict elective surgery capacity during future COVID-19 outbreaks.
Methods:
An international cross-sectional study determined real-world COVID-19-related absence rates among surgeons. COVID-19-related absences included sickness, self-isolation, shielding, and caring for family. To estimate elective surgical capacity during future outbreaks, an expert elicitation study was undertaken with senior surgeons to determine the minimum surgical staff required to provide surgical services while maintaining a range of elective surgery volumes (0, 25, 50 or 75 per cent).
Results
Based on data from 364 hospitals across 65 countries, the COVID-19-related absence rate during the initial 6 weeks of the outbreak ranged from 20.5 to 24.7 per cent (mean average fortnightly). In weeks 7â12, this decreased to 9.2â13.8 per cent. At all times during the COVID-19 outbreak there was predicted to be sufficient surgical staff available to maintain at least 75 per cent of regular elective surgical volume. Overall, there was predicted capacity for surgeon redeployment to support the wider hospital response to COVID-19.
Conclusion:
This framework will inform elective surgical service planning during future COVID-19 outbreaks. In most settings, surgeon absence is unlikely to be the factor limiting elective surgery capacity
Global access to technologies to support safe and effective inguinal hernia surgery:prospective, international cohort study
Technological advancement is important to improve healthcare quality and safety, especially in surgery1. For patients with an inguinal hernia, mesh and minimally invasive surgery are the two main technologies that have improved healthcare quality and safety2,3. The use of mesh is proven to reduce recurrence4,5. This avoids the need for further repairs, which are technically more challenging and have a higher risk for patients6. The use of minimally invasive surgery has proven advantages in bilateral hernias and in female patients2,3 and is recommended in unilateral repair where appropriate expertise is available2,3.Access to these technologies and the expertise required are not widely or equitably distributed at a global level. As it is the case for other technologies, countries in the Global South have more limited access1. At the same time, in this part of the globe, there is a higher prevalence and a higher burden of disease associated with inguinal hernias7. Several barriers to implementation in the Global South have been identified previously, including costs, distribution, and training8,9. To overcome these, studies reporting the use of mesh based on mosquito net mesh and evaluating training programmes have been conducted10,11. With these efforts and with global investment in new technologies and the expansion of existing technologies, it was expected that there would be an increase in their use in lowâmiddle-income countries. Data assessing this variability have not been collected in a standardized way and are usually reported from single-country or single-region studies5,12. Therefore, identification of areas where improvement is most needed will be key to better inform policymakers.The overarching aim of this study was to evaluate access to technologies that are relevant to the treatment of inguinal hernia patients to identify the areas where improvement is needed. Therefore, the primary aim of this study was to evaluate the use of mesh and predictors of mesh use in elective inguinal hernia repairs and the secondary aims of this study were to evaluate the use of minimally invasive surgery and predictors of minimally invasive surgery use and to evaluate the safety associated with the use of mesh and the use of minimally invasive surgery
Calibration of the Logarithmic-Periodic Dipole Antenna (LPDA) Radio Stations at the Pierre Auger Observatory using an Octocopter
An in-situ calibration of a logarithmic periodic dipole antenna with a
frequency coverage of 30 MHz to 80 MHz is performed. Such antennas are part of
a radio station system used for detection of cosmic ray induced air showers at
the Engineering Radio Array of the Pierre Auger Observatory, the so-called
Auger Engineering Radio Array (AERA). The directional and frequency
characteristics of the broadband antenna are investigated using a remotely
piloted aircraft (RPA) carrying a small transmitting antenna. The antenna
sensitivity is described by the vector effective length relating the measured
voltage with the electric-field components perpendicular to the incoming signal
direction. The horizontal and meridional components are determined with an
overall uncertainty of 7.4^{+0.9}_{-0.3} % and 10.3^{+2.8}_{-1.7} %
respectively. The measurement is used to correct a simulated response of the
frequency and directional response of the antenna. In addition, the influence
of the ground conductivity and permittivity on the antenna response is
simulated. Both have a negligible influence given the ground conditions
measured at the detector site. The overall uncertainties of the vector
effective length components result in an uncertainty of 8.8^{+2.1}_{-1.3} % in
the square root of the energy fluence for incoming signal directions with
zenith angles smaller than 60{\deg}.Comment: Published version. Updated online abstract only. Manuscript is
unchanged with respect to v2. 39 pages, 15 figures, 2 table
Multi-resolution anisotropy studies of ultrahigh-energy cosmic rays detected at the Pierre Auger Observatory
We report a multi-resolution search for anisotropies in the arrival
directions of cosmic rays detected at the Pierre Auger Observatory with local
zenith angles up to and energies in excess of 4 EeV ( eV). This search is conducted by measuring the angular power spectrum
and performing a needlet wavelet analysis in two independent energy ranges.
Both analyses are complementary since the angular power spectrum achieves a
better performance in identifying large-scale patterns while the needlet
wavelet analysis, considering the parameters used in this work, presents a
higher efficiency in detecting smaller-scale anisotropies, potentially
providing directional information on any observed anisotropies. No deviation
from isotropy is observed on any angular scale in the energy range between 4
and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured; while no
other deviation from isotropy is observed for moments beyond the dipole one.
The corresponding -values obtained after accounting for searches blindly
performed at several angular scales, are in the case of
the angular power spectrum, and in the case of the needlet
analysis. While these results are consistent with previous reports making use
of the same data set, they provide extensions of the previous works through the
thorough scans of the angular scales.Comment: Published version. Added journal reference and DOI. Added Report
Numbe
Azimuthal asymmetry in the risetime of the surface detector signals of the Pierre Auger Observatory
The azimuthal asymmetry in the risetime of signals in Auger surface detector
stations is a source of information on shower development. The azimuthal
asymmetry is due to a combination of the longitudinal evolution of the shower
and geometrical effects related to the angles of incidence of the particles
into the detectors. The magnitude of the effect depends upon the zenith angle
and state of development of the shower and thus provides a novel observable,
, sensitive to the mass composition of cosmic rays
above eV. By comparing measurements with predictions from
shower simulations, we find for both of our adopted models of hadronic physics
(QGSJETII-04 and EPOS-LHC) an indication that the mean cosmic-ray mass
increases slowly with energy, as has been inferred from other studies. However,
the mass estimates are dependent on the shower model and on the range of
distance from the shower core selected. Thus the method has uncovered further
deficiencies in our understanding of shower modelling that must be resolved
before the mass composition can be inferred from .Comment: Replaced with published version. Added journal reference and DO
A search for point sources of EeV photons
Measurements of air showers made using the hybrid technique developed with
the fluorescence and surface detectors of the Pierre Auger Observatory allow a
sensitive search for point sources of EeV photons anywhere in the exposed sky.
A multivariate analysis reduces the background of hadronic cosmic rays. The
search is sensitive to a declination band from -85{\deg} to +20{\deg}, in an
energy range from 10^17.3 eV to 10^18.5 eV. No photon point source has been
detected. An upper limit on the photon flux has been derived for every
direction. The mean value of the energy flux limit that results from this,
assuming a photon spectral index of -2, is 0.06 eV cm^-2 s^-1, and no celestial
direction exceeds 0.25 eV cm^-2 s^-1. These upper limits constrain scenarios in
which EeV cosmic ray protons are emitted by non-transient sources in the
Galaxy.Comment: 28 pages, 10 figures, accepted for publication in The Astrophysical
Journa
Ultrahigh-energy neutrino follow-up of Gravitational Wave events GW150914 and GW151226 with the Pierre Auger Observatory
On September 14, 2015 the Advanced LIGO detectors observed their first
gravitational-wave (GW) transient GW150914. This was followed by a second GW
event observed on December 26, 2015. Both events were inferred to have arisen
from the merger of black holes in binary systems. Such a system may emit
neutrinos if there are magnetic fields and disk debris remaining from the
formation of the two black holes. With the surface detector array of the Pierre
Auger Observatory we can search for neutrinos with energy above 100 PeV from
point-like sources across the sky with equatorial declination from about -65
deg. to +60 deg., and in particular from a fraction of the 90% confidence-level
(CL) inferred positions in the sky of GW150914 and GW151226. A targeted search
for highly-inclined extensive air showers, produced either by interactions of
downward-going neutrinos of all flavors in the atmosphere or by the decays of
tau leptons originating from tau-neutrino interactions in the Earth's crust
(Earth-skimming neutrinos), yielded no candidates in the Auger data collected
within s around or 1 day after the coordinated universal time (UTC)
of GW150914 and GW151226, as well as in the same search periods relative to the
UTC time of the GW candidate event LVT151012. From the non-observation we
constrain the amount of energy radiated in ultrahigh-energy neutrinos from such
remarkable events.Comment: Published version. Added journal reference and DOI. Added Report
Numbe
- âŠ