16 research outputs found

    Which is the most accurate diagnostic procedure in Tamoxifen treated breast cancer patients

    Get PDF
    Purpose: The aim of this study was to evaluate the diagnostic accuracy of bi-dimensional (2D) and three-dimensional (3D) transvaginal ultrasound (TVUS), hysterosonography (HSSG) and hysteroscopy in the detection of endometrial pathology in women treated with tamoxifen (TMX) for breast cancer. Methods: Forty-two patients, affected by breast cancer under treatment with TMX, underwent 2D-3D TVUS, HSSG and hysteroscopy completed by biopsy, after abnormal findings following a routine 2D TVUS examination. Results: 3D-TVUS was more accurate than 2D-TVUS in the detection of atrophic endometrium confirmed by biopsy and in the detection of endometrial polyps. HSSG and hysteroscopy detected atrophic endometrium and endometrial polyps significantly better than ultrasound scan. Endometrial carcinoma was detected in two cases, and in both HSSG and hysteroscopy were 100% diagnostic. Conclusion: In TMX treated breast cancer patients, HSSG and hysteroscopy provide more accurate diagnosis than 2D-3D ultrasound in the detection of treatment related endometrial lesions

    A case of primary Hodgkin's lymphoma of the parotid gland. Case report and differentian diagnosis from Kuttner's Syndrom

    Get PDF
    Abstract We report a rare case of primary Hodgkin’s lymphoma (HL) of the submandibular gland, with initially diagnosis of Kuttner’s Syndrom. A 48 years old man was referred to our hospital foe evaluation of a submandibular mass. Although the initial Fine Needle Aspiration and subsequent cytology was highly suggestive for a cronic sialadenitis with lymphoid cells. After surgical gland removal we obtained a definitive diagnosis of Hodgkin’s lymphoma in submandibular gland a seat where the most common lymphoma tipe is B

    Insight from an Italian Delphi Consensus on EVAR feasibility outside the instruction for use: the SAFE EVAR Study

    Get PDF
    BACKGROUND: The SAfety and FEasibility of standard EVAR outside the instruction for use (SAFE-EVAR) Study was designed to define the attitude of Italian vascular surgeons towards the use of standard endovascular repair (EVAR) for infrarenal abdominal aortic aneurysm (AAA) outside the instruction for use (IFU) through a Delphi consensus endorsed by the Italian Society of Vascular and Endovascular Surgery (Societa Italiana di Chirurgia Vascolare ed Endovascolare - SICVE). METHODS: A questionnaire consisting of 26 statements was developed, validated by an 18 -member Advisory Board, and then sent to 600 Italian vascular surgeons. The Delphi process was structured in three subsequent rounds which took place between April and June 2023. In the first two rounds, respondents could indicate one of the following five degrees of agreement: 1) strongly agree; 2) partially agree; 3) neither agree nor disagree; 4) partially disagree; 5) strongly disagree; while in the third round only three different choices were proposed: 1) agree; 2) neither agree nor disagree; 3) disagree. We considered the consensus reached when >70% of respondents agreed on one of the options. After the conclusion of each round, a report describing the percentage distribution of the answers was sent to all the participants. RESULTS: Two -hundred -forty-four (40.6%) Italian Vascular Surgeons agreed to participate the first round of the Delphi Consensus; the second and the third rounds of the Delphi collected 230 responders (94.3% of the first -round responders). Four statements (15.4%) reached a consensus in the first rounds. Among the 22 remaining statements, one more consensus (3.8%) was achieved in the second round. Finally, seven more statements (26.9%) reached a consensus in the simplified last round. Globally, a consensus was reached for almost half of the proposed statements (46.1%). CONCLUSIONS: The relatively low consensus rate obtained in this Delphi seems to confirm the discrepancy between Guideline recommendations and daily clinical practice. The data collected could represent the source for a possible guidelines' revision and the proposal of specific Good Practice Points in all those aspects with only little evidence available

    Aspetti immunologici della poliposi nasale.

    No full text

    Cavoatrial junction stenting in vascular hemodialysis catheter malfunction

    No full text
    : In patients undergoing hemodialytic treatment via intravascular catheters, stenosis or occlusion of central veins is common. Despite an extensive characterization of Superior Vena Cava Syndrome (SVCS) no data is available about CavoAtrial Junction (CAJ) stenosis. We report the case of two patients with a story of multiple catheter failures due to thrombosis or infection. Computed tomography (CT) showed radiological signs of CAJ stenosis confirmed at the following venography. In absence of other feasible options to place a vascular access, the two underwent stenting with Gore Viabahn VBX balloon expandable endoprosthesis (W.L. Gore & Associates, Flagstaff, AZ, USA) of the CAJ stenosis. Completion venography showed complete resolution of the stenosis in both patients. No complications occurred during the procedures. At a mean follow-up of 878 ± 559 days no signs of in-stent restenosis or recoil were found. The present cases emphasize the feasibility and safety of CAJ stenting, underlining the importance of preserving CAJ and upper veins patency in hemodialysis access

    Risultati della terapia desensibilizzante locale nella rinite allergica.

    No full text
    corecore