84 research outputs found
Real-space observation of current-driven domain wall motion in submicron magnetic wires
Spintronic devices, whose operation is based on the motion of a magnetic
domain wall (DW), have been proposed recently. If a DW could be driven directly
by flowing an electric current instead of a magnetic field, the performance and
functions of such device would be drastically improved. Here we report
real-space observation of the current-driven DW motion by using a well-defined
single DW in a micro-fabricated magnetic wire with submicron width. Magnetic
force microscopy (MFM) visualizes that a single DW introduced in the wire is
displaced back and forth by positive and negative pulsed-current, respectively.
We can control the DW position in the wire by tuning the intensity, the
duration and the polarity of the pulsed-current. It is, thus, demonstrated that
spintronic device operation by the current-driven DW motion is possible.Comment: Accepted and published in PR
Propagation of a magnetic domain wall in magnetic wires with asymmetric notches
The propagation of a magnetic domain wall (DW) in a submicron magnetic wire
consisting of a magnetic/nonmagnetic/magnetic trilayered structure with
asymmetric notches was investigated by utilizing the giant magnetoresistance
effect. The propagation direction of a DW was controlled by a pulsed local
magnetic field, which nucleates the DW at one of the two ends of the wire. It
was found that the depinning field of the DW from the notch depends on the
propagation direction of the DW.Comment: 12 pages, 3 figure
Effect of Joule heating in current-driven domain wall motion
It was found that high current density needed for the current-driven domain
wall motion results in the Joule heating of the sample. The sample temperature,
when the current-driven domain wall motion occurred, was estimated by measuring
the sample resistance during the application of a pulsed-current. The sample
temperature was 750 K for the threshold current density of 6.7 x 10^11 A/m2 in
a 10 nm-thick Ni81Fe19 wire with a width of 240 nm. The temperature was raised
to 830 K for the current density of 7.5 x 10^11 A/m2, which is very close to
the Curie temperature of bulk Ni81Fe19. When the current density exceeded 7.5 x
10^11 A/m2, an appearance of a multi-domain structure in the wire was observed
by magnetic force microscopy, suggesting that the sample temperature exceeded
the Curie temperature.Comment: 13 pages, 4 figure
Dephasing Effects by Ferromagnetic Boundary on Resistivity in Disordered Metallic Layer
The resistivity of disordered metallic layer sandwiched by two ferromagnetic
layers at low-temperature is investigated theoretically. It is shown that the
magnetic field acting at the interface does not affect the classical Boltzmann
resistivity but causes a dephasing among electrons in the presence of the
spin-orbit interaction, suppressing the anti-localization due to the spin-orbit
interaction. The dephasing turns out to be stronger in the case where the
magnetization of the two layers is parallel, contributing to a positive
magnetoresistance close to a switching field at low temperature.Comment: 11 pages, 3 figures. Title modified in journal versio
Development and psychometric properties of knee-specific body-perception questionnaire in people with knee osteoarthritis: The Fremantle Knee Awareness Questionnaire
Background: Recent systematic reviews have demonstrated that pain associated with knee osteoarthritis (OA) is a complex phenomenon that involves various contributors. People with knee OA exhibit symptoms of impaired body-perception, including reduced tactile acuity, impairments in limb laterality recognition, and degraded proprioceptive acuity. The Fremantle Back Awareness Questionnaire (FreBAQ) was developed to assess body-perception specific to the back in people with chronic low back pain. The aim of this study was to develop and assess the psychometric properties of a knee-specific version of the FreBAQ-J (FreKAQ-J), determine whether people with knee pain experience perceptual impairments and investigate the relationship between disturbed self-perception and clinical status.
Methods: Sixty-five people with knee OA completed the FreKAQ-J. A subset of the participants completed the FreKAQ-J again two-weeks later. Rasch analysis was used to assess item order, targeting, category ordering, unidimensionality, person fit, internal consistency, and differential item functioning. Validity was investigated by examining the relationship between the FreKAQ-J and clinical valuables.
Results: The FreKAQ-J had acceptable internal consistency, unidimensionality, good test-retest reliability, and was functional on the category rating scale. The FreKAQ-J was significantly correlated with pain in motion, disability, pain-related catastrophizing, fear of movement, and anxiety symptomatology.
Conclusions: We developed FreKAQ-J by modifying the FreBAQ-J. The FreKAQ-J fits the Rasch measurement model well and is suitable for use in people with knee OA. Altered body perception may be worth evaluating when managing people with knee OA
Validation of the Japanese version of the Fremantle Back Awareness Questionnaire in patients with low back pain
Background: There is a growing interest in the role of disturbed body perception in people with persistent pain problems such as chronic low back pain (CLBP). A questionnaire, the Fremantle Back Awareness Questionnaire (FreBAQ), was recently developed as a simple and quick way of assessing disturbed perceptual awareness of the back in people with CLBP and appears to have acceptable psychometric properties. The aim of the present study was to develop a Japanese version of the FreBAQ (FreBAQ-J) and evaluate its psychometric properties in a sample of Japanese people with low back pain (LBP).
Methods: Translation of the FreBAQ into Japanese was conducted using a forward-backward method. One hundred participants with LBP completed the resultant FreBAQ-J. A subset of the participants completed the FreBAQ-J again 2 weeks later. Validity was investigated by examining the relationship between the FreBAQ-J and clinical valuables. Rasch analysis was used to assess targeting, category ordering, unidimensionality, person fit, internal consistency, and differential item functioning.
Results: The FreBAQ-J was significantly correlated with pain in motion, disability, pain-related catastrophizing, fear of movement, and anxiety symptomatology. The FreBAQ-J had acceptable internal consistency, a minor departure from unidimensionality, and good test-retest reliability, and was functional on the category rating scale.
Conclusions: The FreBAQ-J has acceptable psychometric properties and is suitable for use in people with LBP. Participants with high levels of disturbed body perception are well targeted by the scale. The functioning of one item (item 8) was poor. Further study is warranted to confirm if this item should be exclude
Magnetoresistance, Micromagnetism, and Domain Wall Scattering in Epitaxial hcp Co Films
Large negative magnetoresistance (MR) observed in transport measurements of
hcp Co films with stripe domains were recently reported and interpreted in
terms of a novel domain wall (DW) scattering mechanism. Here detailed MR
measurements, magnetic force microscopy, and micromagnetic calculations are
combined to elucidate the origin of MR in this material. The large negative
room temperature MR reported previously is shown to be due to ferromagnetic
resistivity anisotropy. Measurements of the resistivity for currents parallel
(CIW) and perpendicular to DWs (CPW) have been conducted as a function of
temperature. Low temperature results show that any intrinsic effect of DWs
scattering on MR of this material is very small compared to the anisotropic MR.Comment: 5 pages, 5 Figures, submitted to PR
Spin dependent scattering of a domain-wall of controlled size
Magnetoresistance measurements in the CPP geometry have been performed on
single electrodeposited Co nanowires exchange biased on one side by a sputtered
amorphous GdCo layer. This geometry allows the stabilization of a single domain
wall in the Co wire, the thickness of which can be controlled by an external
magnetic field. Comparing magnetization, resistivity, and magnetoresistance
studies of single Co nanowires, of GdCo layers, and of the coupled system,
gives evidence for an additional contribution to the magnetoresistance when the
domain wall is compressed by a magnetic field. This contribution is interpreted
as the spin dependent scattering within the domain wall when the wall thickness
becomes smaller than the spin diffusion length.Comment: 9 pages, 13 figure
- …