26 research outputs found
Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial
AIM:
To verify the safety and efficacy of Ologen (OLO) implant as adjuvant compared with low-dosage mitomycin-C (MMC) in trabeculectomy.
METHODS:
This was a prospective randomized clinical trial with a 24-month follow-up. Forty glaucoma patients (40 eyes) were assigned to trabeculectomy with MMC or OLO. Primary outcome includes target IOP at ≤21, ≤17, and ≤15 mm Hg; complete (target IOP without medications), and qualified success (target IOP regardless of medications). Secondary outcomes include bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain optical coherence tomography (SD-OCT) examination; number of glaucoma medications; and frequency of postoperative adjunctive procedures and complications.
RESULTS:
The mean preoperative IOP was 26.5 (±5.2) in MMC and 27.3 (±6.0) in OLO eyes, without statistical significance. One-day postoperatively, the IOP dropped to 5.2 (±3.5) and 9.2 (±5.5) mm Hg, respectively (P=0.009). The IOP reduction was significant at end point in all groups (P=0.01), with a mean IOP of 16.0 (±2.9) and 16.5 (±2.1) mm Hg in MMC and OLO, respectively. The rates and Kaplan-Meier curves did not differ for both complete and qualified success at any target IOP. The bleb height in OLO group was higher than MMC one (P<0.05). SD-OCT analysis of successful/unsuccessful bleb in patients with or without complete success at IOP ≤17  mm Hg indicated a sensitivity of 83% and 73% and a specificity of 75% and 67%, respectively, for MMC and OLO groups. No adverse reaction to OLO was noted.
CONCLUSIONS:
Our results suggest that OLO implant could be a new, safe, and effective alternative to MMC, with similar long-term success rate
Improved Outcomes with Heavy Silicone Oil in Complex Primary Retinal Detachment: A Large Multicenter Matched Cohort Study
\ua9 2023 American Academy of OphthalmologyPurpose: To establish whether Densiron 68, a heavier-than-water endotamponade agent, is an effective alternative to conventional light silicone oil in primary rhegmatogenous retinal detachment (RD) surgery for eyes with inferior breaks in the detached retina and severe proliferative vitreoretinopathy (PVR). Design: Cohort study of routinely collected data from the European Society of Retina Specialists and British and Eire Association of Vitreoretinal Surgeons vitreoretinal database between 2015 and 2022. Participants: All consecutive eyes that underwent primary rhegmatogenous RD surgery using Densiron 68 or light silicone oil as an internal tamponade agent. Methods: To minimize confounding bias, we undertook 2:1 nearest-neighbor matching on inferior breaks, large inferior rhegmatogenous RDs, PVR, and, for visual analyses, baseline visual acuity (VA) between treatment groups. We fit regression models including prognostically relevant covariates, treatment–covariate interactions, and matching weights. We used g-computation with cluster-robust methods to estimate marginal effects. For nonlinear models, we calculated confidence intervals (CIs) using bias-corrected cluster bootstrapping with 9999 replications. Main Outcome Measures: Presence of a fully attached retina and VA at least 2 months after oil removal. Results: Of 1061 eyes enrolled, 426 and 239 were included in our matched samples for anatomic and visual outcome analyses, respectively. The primary success rate was higher in the Densiron 68 group (113 of 142; 80%) compared with the light silicone oil group (180 of 284; 63%), with an adjusted odds ratio of 1.90 (95% CI, 1.63–2.23, P < 0.001). We also observed a significant improvement favoring Densiron 68 of –0.26 logarithm of the minimum angle of resolution (logMAR) in postoperative VA between the 2 groups (95% CI, –0.43 to –0.10, P = 0.002). The anatomic benefit of using Densiron 68 in eyes with inferior retinal breaks and large detachments was more pronounced among eyes with PVR grade C. We found no evidence of visual effect moderation by anatomic outcome or foveal attachment. Conclusions: Densiron achieved higher anatomic success rates and improved visual outcomes compared with conventional light silicone oil in eyes with inferior retinal pathology and severe PVR. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article
The effect of cataract on early stage glaucoma detection using spatial and temporal contrast sensitivity tests
Background:
To investigate the effect of cataract on the ability of spatial and temporal contrast sensitivity tests used to detect early glaucoma.
Methods:
Twenty-seven glaucoma subjects with early cataract (mean age 60 ±10.2 years) which constituted the test group were recruited together with twenty-seven controls (cataract only) matched for age and cataract type from a primary eye care setting. Contrast sensitivity to flickering gratings at 20 Hz and stationary gratings with and without glare, were measured for 0.5, 1.5 and 3 cycles per degree (cpd) in central vision. Perimetry and structural measurements with the Heidelberg Retinal Tomograph (HRT) were also performed.
Results:
After considering the effect of cataract, contrast sensitivity to stationary gratings was reduced in the test group compared with controls with a statistically significant mean difference of 0.2 log units independent of spatial frequency. The flicker test showed a significant difference between test and control group at 1.5 and 3 cpd (p = 0.019 and p = 0.011 respectively). The percentage of glaucoma patients who could not see the temporal modulation was much higher compared with their cataract only counterparts. A significant correlation was found between the reduction of contrast sensitivity caused by glare and the Glaucoma Probability Score (GPS) as measured with the HRT (p<0.005).
Conclusions:
These findings indicate that both spatial and temporal contrast sensitivity tests are suitable for distinguishing between vision loss as a consequence of glaucoma and vision loss caused by cataract only. The correlation between glare factor and GPS suggests that there may be an increase in intraocular stray light in glaucoma
Dimethyl fumarate in patients admitted to hospital with COVID-19 (RECOVERY): a randomised, controlled, open-label, platform trial
Dimethyl fumarate (DMF) inhibits inflammasome-mediated inflammation and has been proposed as a treatment for patients hospitalised with COVID-19. This randomised, controlled, open-label platform trial (Randomised Evaluation of COVID-19 Therapy [RECOVERY]), is assessing multiple treatments in patients hospitalised for COVID-19 (NCT04381936, ISRCTN50189673). In this assessment of DMF performed at 27 UK hospitals, adults were randomly allocated (1:1) to either usual standard of care alone or usual standard of care plus DMF. The primary outcome was clinical status on day 5 measured on a seven-point ordinal scale. Secondary outcomes were time to sustained improvement in clinical status, time to discharge, day 5 peripheral blood oxygenation, day 5 C-reactive protein, and improvement in day 10 clinical status. Between 2 March 2021 and 18 November 2021, 713 patients were enroled in the DMF evaluation, of whom 356 were randomly allocated to receive usual care plus DMF, and 357 to usual care alone. 95% of patients received corticosteroids as part of routine care. There was no evidence of a beneficial effect of DMF on clinical status at day 5 (common odds ratio of unfavourable outcome 1.12; 95% CI 0.86-1.47; p = 0.40). There was no significant effect of DMF on any secondary outcome
Dimethyl fumarate in patients admitted to hospital with COVID-19 (RECOVERY): a randomised, controlled, open-label, platform trial
Dimethyl fumarate (DMF) inhibits inflammasome-mediated inflammation and has been proposed as a treatment for patients hospitalised with COVID-19. This randomised, controlled, open-label platform trial (Randomised Evaluation of COVID-19 Therapy [RECOVERY]), is assessing multiple treatments in patients hospitalised for COVID-19 (NCT04381936, ISRCTN50189673). In this assessment of DMF performed at 27 UK hospitals, adults were randomly allocated (1:1) to either usual standard of care alone or usual standard of care plus DMF. The primary outcome was clinical status on day 5 measured on a seven-point ordinal scale. Secondary outcomes were time to sustained improvement in clinical status, time to discharge, day 5 peripheral blood oxygenation, day 5 C-reactive protein, and improvement in day 10 clinical status. Between 2 March 2021 and 18 November 2021, 713 patients were enroled in the DMF evaluation, of whom 356 were randomly allocated to receive usual care plus DMF, and 357 to usual care alone. 95% of patients received corticosteroids as part of routine care. There was no evidence of a beneficial effect of DMF on clinical status at day 5 (common odds ratio of unfavourable outcome 1.12; 95% CI 0.86-1.47; p = 0.40). There was no significant effect of DMF on any secondary outcome
Mass and charge balance in self-assembled multilayer films on gold. Measurements with optical reflectometry and quartz crystal microbalance
International audienc
Artérite gigantocellulaire : apport de l’écho-doppler
International audienceGiant cell arteritis is the most common primary vasculitis of large-vessel occurring in subjects over 50 years of age. Many imaging techniques has been evaluated to improve the diagnosis of giant cell arteritis. Among these imaging techniques, ultrasound has shown good performances to detect inflammatory involvement of the temporal arteries as well as branches of the aorta. Several publications and recent EULAR recommendations have emhasized the place of this tool in the diagnosis of giant cell arteritis.L’artérite à cellules géantes est la plus fréquente des vascularites primitives des artères de gros calibre survenant chez les sujets de plus de 50 ans. Plusieurs examens d’imagerie ont été évalués dans le but d’affiner le diagnostic de l’artérite à cellules géantes. Parmi ces techniques, l’écho-doppler a montré de bonnes performances pour dépister une atteinte inflammatoire des artères temporales ainsi que des branches de l’aorte. Plusieurs publications et les récentes recommandations de l’EULAR ont réaffirmé la place de cette technique dans le diagnostic d’artérite à cellules géantes
Longitudinal nerve fibre layer thickness change in normal-pressure glaucoma
PURPOSE: To investigate longitudinal retinal nerve fibre layer (RNFL) thickness change in patients with normal-pressure glaucoma (NPG) and to assess how this may be related to visual fields. METHODS: NPG patients and normal subjects who had had serial GDx nerve fibre layer Analyzer II imaging and Humphrey visual fields performed at least 18 months apart were selected for study. These measurements were compared between groups at baseline and at subsequent follow-up, for change over time. RESULTS: Seventy-five NPG patients and 35 normal subjects were studied. Significant differences in RNFL thickness were found between NPG patients and normal controls at baseline (P < or = 0.001). Over the same time, there was greater RNFL thinning in NPG patients than in normal subjects (P < or = 0.0001). RNFL thinning in NPG was negatively correlated with visual field log MD at baseline (P < 0.001) and change in MD over time (P < 0.001). CONCLUSION: Reduction of RNFL thickness over time was significantly greater in NPG patients than in normal subjects, indicating that NPG patients' RNFL had thinned at a faster rate. NPG patients with initially better visual fields had a greater reduction in RNFL thickness than did those with initially more advanced visual field defects, suggesting that more RNFL change may be observed when glaucoma is at an earlier stage. There was a direct relationship between RNFL thinning and visual field deterioration