9,448 research outputs found
Relative intensity squeezing by four-wave mixing with loss: an analytic model and experimental diagnostic
Four-wave mixing near resonance in an atomic vapor can produce relative
intensity squeezed light suitable for precision measurements beyond the
shot-noise limit. We develop an analytic distributed gain/loss model to
describe the competition of mixing and absorption through the non-linear
medium. Using a novel matrix calculus, we present closed-form expressions for
the degree of relative intensity squeezing produced by this system. We use
these theoretical results to analyze experimentally measured squeezing from a
Rb vapor and demonstrate the analytic model's utility as an experimental
diagnostic.Comment: 10 pages, 5 figure
A polymer coated cicaprost-eluting stent increases neointima formation and impairs vessel function in the rabbit iliac artery
Drug-eluting stents have been successful in reducing in-stent restenosis but are not suitable for all lesion types and have been implicated in causing late stent thrombosis due to incomplete regeneration of the endothelial cell layer. In this study we implanted stents coated with cicaprost, a prostacyclin analogue with a long plasma half-life and antiproliferative effects on vascular smooth muscle cells, into the iliac arteries of rabbits. At 28-day follow-up we compared neointima formation within the stented vessels and vascular function in adjacent vessels, to assess if cicaprost could reduce restenosis without impairing vessel function. Arteries implanted with cicaprost eluting stents had significantly more neointima compared to bare metal stents. In adjacent segments of artery, endothelium-dependent relaxation was impaired by the cicaprost-eluting stent but vasodilation to an endothelium-independent vasodilator was maintained. We conclude that the presence of the polymer and sub-optimal release of cicaprost from the stent may be responsible for the increased neointma and impaired functional recovery of the endothelium observed. Further experiments should be aimed at optimising release of cicaprost and exploring different stent polymer coatings
Characterization and expression analysis of Staphylococcus aureus pathogenicity island 3 - Implications for the evolution of staphylococcal pathogenicity islands
We describe the complete sequence of the 15.9-kb staphylococcal pathogenicity island 3 encoding staphylococcal enterotoxin serotypes B, K, and Q. The island, which meets the generally accepted definition of pathogenicity islands, contains 24 open reading frames potentially encoding proteins of more than 50 amino acids, including an apparently functional integrase. The element is bordered by two 17-bp direct repeats identical to those found flanking staphylococcal pathogenicity island 1. The island has extensive regions of homology to previously described pathogenicity islands, particularly staphylococcal pathogenicity islands 1 and bov. The expression of 22 of the 24 open reading frames contained on staphylococcal pathogenicity island 3 was detected either in vitro during growth in a laboratory medium or serum or in vivo in a rabbit model of toxic shock syndrome using DNA microarrays. The effect of oxygen tension on staphylococcal pathogenicity island 3 gene expression was also examined. By comparison with the known staphylococcal pathogenicity islands in the context of gene expression described here, we propose a model of pathogenicity island origin and evolution involving specialized transduction events and addition, deletion, or recombination of pathogenicity island "modules.
SAGE 3: A visible wavelength limb sounder
A brief description is presented for the SAGE 3 (Stratospheric Aerosol and Gas Experiment 3) instrument that has been selected to fly onboard the National Polar Platform 1 (NPOP 1) for the Earth Observational System (Eos) in 1996. The SAGE 3 instrument will perform earth limb sounding with the solar occultation technique measuring the ultraviolet (UV), the visible, and the near infrared (IR) wavelength solar radiation. The instrument will produce atmospheric data for the vertical distribution of aerosol, ozone, nitrogen dioxide, water vapor, and oxygen. The details of the instrument design, data flow, and processing requirements are discussed
Can the ischemic penumbra be identified on noncontrast CT of acute stroke?
<p><b>Background and Purpose:</b> Early ischemic changes on noncontrast CT in acute stroke include both hypoattenuation and brain swelling, which may have different pathophysiological significance.</p>
<p><b>Methods:</b> Noncontrast CT and CT perfusion brain scans from patients with suspected acute stroke <6 hours after onset were reviewed. Five raters independently scored noncontrast CTs blind to clinical data using the Alberta Stroke Program Early CT Score (ASPECTS). Each ASPECTS region was scored as hypodense or swollen. A separate reviewer measured time to peak and cerebral blood volume in each ASPECTS region on CT perfusion. Time to peak and cerebral blood volume were compared for each region categorized as normal, hypodense, or isodense and swollen.</p>
<p><b>Results:</b> Scans of 32 subjects a median 155 minutes after onset yielded 228 regions with both CT perfusion and noncontrast CT data. Isodense swelling was associated with significantly higher cerebral blood volume (P=0.016) and with penumbral perfusion (posttest:pretest likelihood ratio 1.44 [95% CI: 0.68 to 2.90]), whereas hypodensity was associated with more severe time to peak delay and with core perfusion (likelihood ratio 3.47 [95% CI: 1.87 to 6.34]). Neither isodense swelling nor hypodensity was sensitive for prediction of perfusion pattern, but appearances were highly specific (87.2% and 91.0% for penumbra and core, respectively). Intrarater agreement was good or excellent, but interrater agreement for both hypodensity and swelling was poor.</p>
<p><b>Conclusions:</b> Regions exhibiting hypoattenuation are likely to represent the infarct core, whereas regions that are isodense and swollen have increased cerebral blood volume and are more likely to signify penumbral perfusion. Although noncontrast CT is not sensitive for detection of core and penumbra, appearances are specific. Some information on tissue viability can therefore be obtained from noncontrast CT.</p>
Fluctuations and Pinch-Offs Observed in Viscous Fingering
Our experiments on viscous (Saffman-Taylor) fingering in Hele-Shaw channels
reveal several phenomena that were not observed in previous experiments. At low
flow rates, growing fingers undergo width fluctuations that intermittently
narrow the finger as they evolve. The magnitude of these fluctuations is
proportional to Ca^{-0.64}, where Ca is the capillary number, which is
proportional to the finger velocity. This relation holds for all aspect ratios
studied up to the onset of tip instabilities. At higher flow rates, finger
pinch-off and reconnection events are observed. These events appear to be
caused by an interaction between the actively growing finger and suppressed
fingers at the back of the channel. Both the fluctuation and pinch-off
phenomena are robust but not explained by current theory.Comment: 6 pages, 3 figures; to appear in Proceedings of the Seventh
Experimental Chaos Conferenc
Fluctuations and Pinch-Offs Observed in Viscous Fingering
Our experiments on viscous (Saffman-Taylor) fingering in Hele-Shaw channels
reveal several phenomena that were not observed in previous experiments. At low
flow rates, growing fingers undergo width fluctuations that intermittently
narrow the finger as they evolve. The magnitude of these fluctuations is
proportional to Ca^{-0.64}, where Ca is the capillary number, which is
proportional to the finger velocity. This relation holds for all aspect ratios
studied up to the onset of tip instabilities. At higher flow rates, finger
pinch-off and reconnection events are observed. These events appear to be
caused by an interaction between the actively growing finger and suppressed
fingers at the back of the channel. Both the fluctuation and pinch-off
phenomena are robust but not explained by current theory.Comment: 6 pages, 3 figures; to appear in Proceedings of the Seventh
Experimental Chaos Conferenc
Observations of atmospheric water vapor with the SAGE 2 instrument
The Stratospheric Aerosol and Gas Experiment 2 (SAGE 2) is discussed. The SAGE 2 instrument was a multichannel spectrometer that inferred the vertical distribution of water vapor, aerosols, nitrogen dioxide, and ozone by measuring the extinction of solar radiation at spacecraft sunrise/sunset. At altitudes above 20 km, the SAGE 2 and LIMS (Limb Infrared Monitor of the Stratosphere) data are in close agreement. The discrepancies below this altitude may be attributed to differences in the instruments' field of view and time of data acquisition
A Global Overview of Bio-economy Strategies and Visions
This overview provides a comparative analysis of strategies and visions for the bio-economy. It concentrates on the US, EU, Finland, Germany, Sweden, Canada and Australia. It comments on China, Russia, Brazil and Malaysia. It also briefly outlines the OECD policy agenda for the bio-economy
- …