4 research outputs found

    Laryngeal dysplasia: aetiology and molecular biology

    No full text

    Effects of maturation on parameters used for pass/fail criteria in neonatal hearing screening programmes using evoked otoacoustic emissions

    No full text
    We aimed to investigate the incidence of false alarms that occurred with the pass/fail criteria used in a published series of neonatal hearing screening programmes, as a function of age. We analysed the database of 19137 normally hearing babies (38274 ears) tested in the Wessex Universal Neonatal Hearing Screening Project. Otoacoustic emissions were recorded prior to discharge from maternity units, using IL088 equipment. We assessed the pass/fail rate using the Wessex criteria and 10 other pass/fail criteria published in the literature. Using Pearson's correlation coefficient, a statistically significant correlation between signal-to-noise ratio at each of the frequency bands 1, 2, 3, 4 and 5 kHz and babies' age in hours at the 0.01 level was identified. The correlation was also significant (0.01 level) between age and frequency reproducibility in each of the bands at 1, 2, 3, 4 and 5 kHz as well as the whole reproducibility. The number of false alarms reduced significantly after the first 24 h of life with all the criteria examined. We conclude that in the first hours after birth due to insufficient maturation of the otoacoustic emission, there is a high rate of false alarms. This increase in the false alarm rate, whilst dependent on the criteria used, occurs with all criteria. This leads to the consideration of whether the establishment of age-dependent pass/fail criteria could reduce the false alarm rate and the subsequent strain on diagnostic centres. Copyright (c) 2007 S. Karger AG, Base

    Can radiological results be surrogate markers of functional outcome in distal radial extra-articular fractures?

    No full text
    The purpose of this study was to evaluate the relationship between radiological and functional results in patients with extra-articular fractures of the distal radius. We conducted a prospective study of radiological and functional assessment in 95 consecutively selected extra-articular distal radius fractures. There were two patient groups: more than 60 and less than 60 years of age. The final fracture union radiographs were analysed for their functional outcome using the Michigan Hand Outcomes Questionnaire (MHQ) and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire. In patients with acceptable radiological results, 62% (MHQ group) and 72% (DASH group) of patients had satisfactory functional outcome. Analysing patients with satisfactory functional results, 56% (MHQ group) and 59% (DASH group) had satisfactory radiological results. There was a higher proportion of patients with better functional results, despite poor radiological results, in both of the age groups. There was a statistically significant correlation between satisfactory radial tilt and functional outcome in the younger patients. In the older age group, patients with satisfactory radiological results had satisfactory functional outcome (p < 0.05). However, in the older age group, satisfactory functional results were achieved, despite unsatisfactory radiological results
    corecore