15 research outputs found

    Effects of High-Temperature-Pressure Polymerized Resin-Infiltrated Ceramic Networks on Oral Stem Cells

    Get PDF
    International audienceObjectivesThe development of CAD—CAM techniques called for new materials suited to this technique and offering a safe and sustainable clinical implementation. The infiltration of resin in a ceramic network under high pressure and high temperature defines a new class of hybrid materials, namely polymer infiltrated ceramics network (PICN), for this purpose which requires to be evaluated biologically. We used oral stem cells (gingival and pulpal) as an in vitro experimental model.MethodsFour biomaterials were grinded, immersed in a culture medium and deposed on stem cells from dental pulp (DPSC) and gingiva (GSC): Enamic (VITA®), Experimental Hybrid Material (EHM), EHM with initiator (EHMi) and polymerized Z100™ composite material (3M®). After 7 days of incubation; viability, apoptosis, proliferation, cytoskeleton, inflammatory response and morphology were evaluated in vitro.ResultsProliferation was insignificantly delayed by all the tested materials. Significant cytotoxicity was observed in presence of resin based composites (MTT assay), however no detectable apoptosis and some dead cells were detected like in PICN materials. Cell morphology, major cytoskeleton and extracellular matrix components were not altered. An intimate contact appeared between the materials and cells.Clinical SignificanceThe three new tested biomaterials did not exhibit adverse effects on oral stem cells in our experimental conditions and may be an interesting alternative to ceramics or composite based CAD—CAM blocks

    Une première estimation des incertitudes liées à l'échantillonnage de microplastiques en rivière

    No full text
    International audienceMany studies have been conducted to quantify microplastic contamination, but only a few of them have actually the sampling methodology and associated uncertainties. This study seeks to examine the influence of sampling strategy on the confidence interval of river microplastic estimates. 16 samples are collected in the Gave de Pau River (southwestern France) during a three-hour window with a 330-μm mesh size net. Three different exposure times (3, 5 and 7 min) allow for a respective filtration rate by the net of 35.6 m3 (3 samples), 59.4 m3 (10 samples), and 83.2 m3 (3 samples) of water. Organic matter contained in samples is removed by hydrogen peroxide oxidation. The plastic particles are then counted and classified under a binocular microscope. The microplastic concentrations vary between 2.64 and 4.24 microplastics/m3, with a median value of 3.26 microplastics/m3. Statistical analysis does not show differences in microplastic concentrations for the three exposure times. This result seems to demonstrate that a filtration of approx. 35 m3 of water is sufficient under similar conditions (similar flow condition and degree of microplastic contamination) and can help reduce sampling and sample processing time. Other analyses, based on 10 filtrations of 59.4 m3, show that the higher the number of samples, the lower the confidence interval. For triplicates, the mean confidence interval reaches 15% of the median value. Thus, collecting triplicates would seem to offer a reasonable optimum, in combining an acceptable error percentage and time efficiency. These results might depend on the microplastic load of the river, therefore making it necessary to conduct similar analyses on other rivers. This study reports for the first time uncertainties related to microplastic sampling in rivers. Such findings will serve to set up long term monitoring, highlight spatial differences between sites and improve the accuracy of annual microplastic fluxes in rivers

    A first estimation of uncertainties related to microplastic sampling in rivers

    No full text
    International audienceMany studies have been conducted to quantify microplastic contamination, but only a few of them have actually the sampling methodology and associated uncertainties. This study seeks to examine the influence of sampling strategy on the confidence interval of river microplastic estimates. 16 samples are collected in the Gave de Pau River (southwestern France) during a three-hour window with a 330-μm mesh size net. Three different exposure times (3, 5 and 7 min) allow for a respective filtration rate by the net of 35.6 m3 (3 samples), 59.4 m3 (10 samples), and 83.2 m3 (3 samples) of water. Organic matter contained in samples is removed by hydrogen peroxide oxidation. The plastic particles are then counted and classified under a binocular microscope. The microplastic concentrations vary between 2.64 and 4.24 microplastics/m3, with a median value of 3.26 microplastics/m3. Statistical analysis does not show differences in microplastic concentrations for the three exposure times. This result seems to demonstrate that a filtration of approx. 35 m3 of water is sufficient under similar conditions (similar flow condition and degree of microplastic contamination) and can help reduce sampling and sample processing time. Other analyses, based on 10 filtrations of 59.4 m3, show that the higher the number of samples, the lower the confidence interval. For triplicates, the mean confidence interval reaches 15% of the median value. Thus, collecting triplicates would seem to offer a reasonable optimum, in combining an acceptable error percentage and time efficiency. These results might depend on the microplastic load of the river, therefore making it necessary to conduct similar analyses on other rivers. This study reports for the first time uncertainties related to microplastic sampling in rivers. Such findings will serve to set up long term monitoring, highlight spatial differences between sites and improve the accuracy of annual microplastic fluxes in rivers

    In vitro effects of two silicate-based materials, Biodentine and BioRoot RCS, on dental pulp stem cells in models of reactionary and reparative dentinogenesis.

    No full text
    Calcium silicate-based cements are biomaterials with calcium oxide and carbonate filler additives. Their properties are close to those of dentin, making them useful in restorative dentistry and endodontics. The aim of this study was to evaluate the in vitro biological effects of two such calcium silicate cements, Biodentine (BD) and Bioroot (BR), on dental stem cells in both direct and indirect contact models. The two models used aimed to mimic reparative dentin formation (direct contact) and reactionary dentin formation (indirect contact). An original aspect of this study is the use of an interposed thin agarose gel layer to assess the effects of diffusible components from the materials.The two biomaterials were compared and did not modify dental pulp stem cell (DPSC) proliferation. BD and BR showed no significant cytotoxicity, although some cell death occurred in direct contact. No apoptosis or inflammation induction was detected. A striking increase of mineralization induction was observed in the presence of BD and BR, and this effect was greater in direct contact. Surprisingly, biomineralization occurred even in the absence of mineralization medium. This differentiation was accompanied by expression of odontoblast-associated genes. Exposure by indirect contact did not stimulate the induction to such a level.These two biomaterials both seem to be bioactive and biocompatible, preserving DPSC proliferation, migration and adhesion. The observed strong mineralization induction through direct contact highlights the potential of these biomaterials for clinical application in dentin-pulp complex regeneration

    Cytoskeleton and major extracellular matrix proteins were analyzed by immunofluorescence.

    No full text
    <p>Actin was observed in DPSC (A), DPSC with BD (B) and in DPSC with BR (C); vimentin and tubulin (D, E and F); and type 1 collagen and fibronectin (G, H and I). The observed decrease in type 1 collagen, when DPSC were in contact with biomaterials, was confirmed using RT-qPCR (5J), whereas protein secretion was not modified by the experimental conditions (Fig 5K). Scale Bar: 100μm.</p

    Biomaterials and stem cells characteristics.

    No full text
    <p>SEM microphotographs of the powdered materials. Enamic (Fig 1A), EHM (Fig 1B), EHMi (Fig 1C) and Z100 (Fig 1D). FACS analysis of classical mesenchymal stem cells markers (CD29, 90, 105, 146 and STRO1), of hematopoietic cells (CD45) and of endothalium (CD31) for GSC (Fig 1E) and DPSC (Fig 1F). CFU-F assays of the GSC (Fig 1G). Differentiation staining of the GSC after 14 days: Oil Red O staining (Fig 1H) and Alizarin Red S staining (Fig 1I).Scale bar 100μm.</p
    corecore