7 research outputs found

    Rooftop Photovoltaic Energy Production Management in India Using Earth-Observation Data and Modeling Techniques

    No full text
    This study estimates the photovoltaic (PV) energy production from the rooftop solar plant of the National Institute of Technology Karnataka (NITK) and the impact of clouds and aerosols on the PV energy production based on earth observation (EO)-related techniques and solar resource modeling. The post-processed satellite remote sensing observations from the INSAT-3D have been used in combination with Copernicus Atmosphere Monitoring Service (CAMS) 1-day forecasts to perform the Indian Solar Irradiance Operational System (INSIOS) simulations. NITK experiences cloudy conditions for a major part of the year that attenuates the solar irradiance available for PV energy production and the aerosols cause performance issues in the PV installations and maintenance. The proposed methodology employs cloud optical thickness (COT) and aerosol optical depth (AOD) to perform the INSIOS simulations and quantify the impact of clouds and aerosols on solar energy potential, quarter-hourly monitoring, forecasting energy production and financial analysis. The irradiance forecast accuracy was evaluated for 15 min, monthly, and seasonal time horizons, and the correlation was found to be 0.82 with most of the percentage difference within 25% for clear-sky conditions. For cloudy conditions, 27% of cases were found to be within ±50% difference of the percentage difference between the INSIOS and silicon irradiance sensor (SIS) irradiance and it was 60% for clear-sky conditions. The proposed methodology is operationally ready and is able to support the rooftop PV energy production management by providing solar irradiance simulations and realistic energy production estimations

    Aerosol optical depth regime over megacities of the world

    No full text
    Currently, 55 % of the world's population resides in urban areas and this number is projected to increase to 70 % by 2050. Urban agglomerations with a population over 10 million, characterized as megacities, are expected to be more than 100 by 2100. Such large concentrations of population could boost creativity and economic progress, but also raises several environmental challenges such as air quality degradation. In this study, we investigate the spatial and temporal variability of urban aerosol state of 81 cities with a population over 5 million, relying on daily satellite-based aerosol optical depth (AOD) retrievals, derived at fine spatial resolution (0.1° × 0.1°), over an 18-year period spanning from 2003 to 2020. According to our results, the lowest long-term mean AOD values worldwide were found in European and American cities (from 0.08 to 0.20). For almost all African and Asian cities, mean AOD ranged from 0.25 up to 0.90, but a considerable dust aerosol contribution (up to 70 %) was found for some of them with associated mean dust optical depth (DOD) values reaching up to 0.4. Mostly Chinese and Indian cities tend to have higher mean AOD values in the areas surrounding their center, while the opposite was found for most of the cities in the rest of the world. High intraannual AOD variability was revealed for the eastern American cities, while lower values were found in Chinese, eastern Indian and the eastern Mediterranean cities. During the study period, statistically significant negative AOD decadal trends were found for East Asian, European and North American cities, with the greatest decrease of −0.1 to −0.3 per decade recorded for the Chinese cities, in which the maximum mean AODs (0.45–0.91) are observed. In most of the US cities, where low mean AOD <0.17 was recorded, considerable declining AOD trends were found (−30 % to −50 % per decade). For the rest of Asian, African and South American cities, statistically significant AOD increase was found, with the greatest values of +0.07 to +0.16 per decade recorded for Indian cities. In Bengaluru (India), it is reported the lowest mean AOD value (0.2) and the maximum AOD increase (+69 %), which may be partially attributed to the population growth over the study period. The agreement of the satellite-derived AOD trends against those obtained from ground-based AERONET measurements was examined. For ground-based stations within the geographical limits of the contiguous urban area of the examined cities, a 0.93 correlation for the long-term means of AOD was found and ∌75 % of the derived trends agreed in sign. It was found that the spatial homogeneity within the examined satellite domain and the location of the surface station were key factors that determined their agreement. The present study highlights the vital and essential contribution of spaceborne products to monitor aerosol burden over megacities of the planet towards fulfilling the United Nations Sustainable Development Goal of “sustainable cities and communities”, dealing with urban air quality.ISSN:1680-7375ISSN:1680-736

    The Langley Ratio method, a new approach for transferring photometer calibration from direct sun measurements [Discussion paper]

    No full text
    This article presents a new method for transferring calibration from a reference photometer, referred to as the "master'', to a secondary photometer, referred to as the "field'', using a synergetic approach when master and field instruments have different spectral bands. The method was first applied between a PFR, (Precision Filter Radiometer) instrument from the World Optical Depth Research and Calibration Center (WORCC) considered the reference by the WMO (World Meteorological Organization), and a CE318-TS photometer, the standard photometer used by AERONET (AErosol RObotic NETwork). These two photometers have different optics, sun-tracking systems and spectral bands. The Langley Ratio method (LR) proposed in this study was used to transfer calibration to the closest spectral bands for 1-minute synchronous data, for airmasses between 2 and 5, and was compared to the state of the art Langley calibration technique. The study was conducted at two different locations, Izaña Observatory (IZO) and Valladolid, where measurements were collected almost simultaneously over a six-month period under different aerosol regimes. In terms of calibration aspects, our results showed very low relative differences and standard deviations in the calibration constant transferred in Izaña from PFR to Cimel, up to 0.29 % and 0.46 %, respectively, once external factors such as different field-of-view between photometers or the presence of calibration issues were considered. However, these differences were higher in the comparison performed at Valladolid (1.04 %) and in the shorter wavelengths spectral bands (up to 0.78 % in Izaña and 1.61 % in Valladolid)

    Real-time UV index retrieval in Europe using Earth observation-based techniques: system description and quality assessment

    No full text
    This study introduces an Earth observation (EO)-based system which is capable of operationally estimating and continuously monitoring the ultraviolet index (UVI) in Europe. UVIOS (i.e., UV-Index Operating System) exploits a synergy of radiative transfer models with high-performance computing and EO data from satellites (Meteosat Second Generation and Meteorological Operational Satellite-B) and retrieval processes (Tropospheric Emission Monitoring Internet Service, Copernicus Atmosphere Monitoring Service and the Global Land Service). It provides a near-real-time nowcasting and short-term forecasting service for UV radiation over Europe. The main atmospheric inputs for the UVI simulations include ozone, clouds and aerosols, while the impacts of ground elevation and surface albedo are also taken into account. The UVIOS output is the UVI at high spatial and temporal resolution (5 km and 15 min, respectively) for Europe (i.e., 1.5 million pixels) in real time. The UVI is empirically related to biologically important UV dose rates, and the reliability of this EO-based solution was verified against ground-based measurements from 17 stations across Europe. Stations are equipped with spectral, broadband or multi-filter instruments and cover a range of topographic and atmospheric conditions. A period of over 1 year of forecasted 15 min retrievals under all-sky conditions was compared with the ground-based measurements. UVIOS forecasts were within ±0.5 of the measured UVI for at least 70 % of the data compared at all stations. For clear-sky conditions the agreement was better than 0.5 UVI for 80 % of the data. A sensitivity analysis of EO inputs and UVIOS outputs was performed in order to quantify the level of uncertainty in the derived products and to identify the covariance between the accuracy of the output and the spatial and temporal resolution and the quality of the inputs. Overall, UVIOS slightly overestimated the UVI due to observational uncertainties in inputs of cloud and aerosol. This service will hopefully contribute to EO capabilities and will assist the provision of operational early warning systems that will help raise awareness among European Union citizens of the health implications of high UVI doses

    Real-time UV index retrieval in Europe using Earth observation-based techniques: system description and quality assessment

    No full text
    This study introduces an Earth observation (EO)-based system which is capable of operationally estimating and continuously monitoring the ultraviolet index (UVI) in Europe. UVIOS (i.e., UV-Index Operating System) exploits a synergy of radiative transfer models with high-performance computing and EO data from satellites (Meteosat Second Generation and Meteorological Operational Satellite-B) and retrieval processes (Tropospheric Emission Monitoring Internet Service, Copernicus Atmosphere Monitoring Service and the Global Land Service). It provides a near-real-time nowcasting and short-term forecasting service for UV radiation over Europe. The main atmospheric inputs for the UVI simulations include ozone, clouds and aerosols, while the impacts of ground elevation and surface albedo are also taken into account. The UVIOS output is the UVI at high spatial and temporal resolution (5 km and 15 min, respectively) for Europe (i.e., 1.5 million pixels) in real time. The UVI is empirically related to biologically important UV dose rates, and the reliability of this EO-based solution was verified against ground-based measurements from 17 stations across Europe. Stations are equipped with spectral, broadband or multi-filter instruments and cover a range of topographic and atmospheric conditions. A period of over 1 year of forecasted 15 min retrievals under all-sky conditions was compared with the ground-based measurements. UVIOS forecasts were within +/- 0.5 of the measured UVI for at least 70 % of the data compared at all stations. For clear-sky conditions the agreement was better than 0.5 UVI for 80 % of the data. A sensitivity analysis of EO inputs and UVIOS outputs was performed in order to quantify the level of uncertainty in the derived products and to identify the covariance between the accuracy of the output and the spatial and temporal resolution and the quality of the inputs. Overall, UVIOS slightly overestimated the UVI due to observational uncertainties in inputs of cloud and aerosol. This service will hopefully contribute to EO capabilities and will assist the provision of operational early warning systems that will help raise awareness among European Union citizens of the health implications of high UVI doses
    corecore