3,453 research outputs found
Computer Assistance In Discovering Formulas And Theorems In System Engineering II
[HSWcdc94] focused on procedures for simplifying complicated expressions automatically. [HScdc95] turned to the adventurous pursuit of developing a highly computer assisted method for “discovering” certain types of formulas and theorems.
It is often the case that some variables in the formulation of a problem are not the natural “coordinates” for solution of the problem. Gröbner Basis Algorithms, which lie at the core of our method, are very good at eliminating unknowns, but have no way of finding good changes of variables. This paper gives a way of incorporating changes of variables into our method.
As an example, we “discover” the DGKF equations of H∞ control
Hearing Loss and Retarded Cochlear Development in Mice Lacking Type 2 Iodothyronine Deiodinase
The later stages of cochlear differentiation and the developmental onset of hearing require thyroid hormone. Although thyroid hormone receptors (TRs) are a prerequisite for this process, it is likely that other factors modify TR activity during cochlear development. The mouse cochlea expresses type 2 deiodinase (D2), an enzyme that converts thyroxine, the main form of thyroid hormone in the circulation, into 3,5,3\u27-triiodothyronine (T3) the major ligand for TRs. Here, we show that D2-deficient mice have circulating thyroid hormone levels that would normally be adequate to allow hearing to develop but they exhibit an auditory phenotype similar to that caused by systemic hypothyroidism or TR deletions. D2-deficient mice have defective auditory function, retarded differentiation of the cochlear inner sulcus and sensory epithelium, and deformity of the tectorial membrane. The similarity of this phenotype to that caused by TR deletions suggests that D2 controls the T3 signal that activates TRs in the cochlea. Thus, D2 is essential for hearing, and the results suggest that this hormone-activating enzyme confers on the cochlea the ability to stimulate its own T3 response at a critical developmental period
The role of uncertainty intolerance in adjusting to long-term physical health conditions: A systematic review
Long-term physical health conditions (LTPHCs) are associated with poorer psychological well-being, quality of life, and longevity. Additionally, individuals with LTPHCs report uncertainty in terms of condition aetiology, course, treatment, and ability to engage in life. An individual’s dispositional ability to tolerate uncertainty—or difficulty to endure the unknown—is termed intolerance of uncertainty (IU), and may play a pivotal role in their adjustment to a LTPHC. Consequently, the current review sought to investigate the relationship between IU and health-related outcomes, including physical symptoms, psychological ramifications, self-management, and treatment adherence in individuals with LTPHCs. A systematic search was conducted for papers published from inception until 27 May 2022 using the databases PsycINFO, PubMed (MEDLINE), CINAHL Plus, PsycARTICLES, and Web of Science. Thirty-one studies (N = 6,201) met the inclusion criteria. Results indicated that higher levels of IU were associated with worse psychological well-being outcomes and poorer quality of life, though impacts on self-management were less clear. With the exception of one study (which looked at IU in children), no differences in IU were observed between patients and healthy controls. Although findings highlight the importance of investigating IU related to LTPHCs, the heterogeneity and limitations of the existing literature preclude definite conclusions. Future longitudinal and experimental research is required to investigate how IU interacts with additional psychological constructs and disease variables to predict individuals’ adjustment to living with a LTPHC
The Nebraska Natural Legacy Project: State Wildlife Action Plan 2nd edition
Nebraska’s rich biological diversity is composed of thousands of plant and animal species interacting with each other and the environment. The flora and fauna of the state, along with the natural habitats they occupy, form Nebraska’s natural heritage – a legacy that should be treasured just as much as our cultural heritage. Unfortunately, populations of many once common species have declined because of a variety of stresses, including habitat loss, habitat degradation, diseases, and competition and predation from invasive species. While conservation actions in the past have had notable successes, they have not been sufficient to stem the overall tide of species decline. There is a need for a comprehensive, systematic and proactive approach to conserving the full array of Nebraska’s biological diversity. The goals of the Nebraska Natural Legacy Project are to:
1. Reverse the decline of at-risk species (and avoid the need for state or federal listing as threatened or endangered)
2. Recover currently listed species and allow for their de-listing
3. Keep common species common
4. Conserve natural communities
Almost all existing natural habitat in Nebraska, and the biological diversity it supports, resides on lands under private ownership. All Nebraskans can benefit from the strong conservation tradition and sound stewardship of private landowners. The Nebraska Natural Legacy Project seeks to continue this tradition, while at the same time creating new opportunities for collaboration between farmers, ranchers, communities, private and governmental organizations and others for conserving Nebraska’s biological diversity, our natural heritage. The Nebraska Natural Legacy Project is non-regulatory, voluntary, incentive-based conservation. As stewards for the next generation, it is everyone’s responsibility to ensure the treasures that were handed to us by nature and our predecessors are still here for future generations of Nebraskans to enjoy
Experimental and Modeling Improvements to a Co-Fluid Cycle Utilizing Ionic Liquids and Carbon Dioxide
Carbon dioxide is undergoing a renaissance as an alternative to synthetic refrigerants due to its environmental advantages in addition to a high density and excellent transport properties. A weakness of carbon dioxide is having a critical point which occurs at a lower temperature and higher pressure than most other fluids used as refrigerants. This combination leads to high operating pressures, especially on the heat rejection side of the thermodynamic cycle. Ionic liquids, which are salts which remain in their liquid phase at room temperatures, have been shown to strongly absorb carbon dioxide. Due to recent advances in ionic liquids, the cation and anion groups are able to be formulated to tailor a variety of fluid properties including liquid-vapor equilibrium characteristics. By selecting appropriate ionic liquids, it is possible to reduce the operating pressure of an air-conditioning system utilizing carbon dioxide to be in the range of conventional refrigerants. Not only are ionic liquids able to physically absorb volatile refrigerants as in other co-fluid cycles, but ionic liquids also offer the possibility of chemical absorption thereby giving the opportunity for greater enthalpy changes. Conceptually, the ionic co-fluid cycle is similar to a traditional vapor compression cycle. In the high pressure heat exchanger, heat is rejected to lower the enthalpy and to absorb carbon dioxide into the ionic liquid. The enthalpy is further reduced in an internal heat exchanger before the high pressure liquid is passed through a valve to decrease the pressure which causes the fluid mixture to cool. Heat is absorbed by the mixture from the environment, thus boiling additional carbon dioxide. After passing through an internal heat exchanger, the fluid is mechanically compressed and the cycle is repeated. System modeling work was utilized to identify important thermodynamic characteristics for achieving good performance. These characteristics included heats of mixing, solubility, entropy of mixing, and viscosity. Using experimentally and numerically determined IL-CO2 mixture properties, system models were able to predicatively select anion and cation pairs for optimizing performance. The ionic liquids selected from the modeling exercises were subsequently synthesized for demonstration in a laboratory. An air conditioning system was built from components designed for use with conventional refrigerants. The system was installed in a facility which was instrumented to measure air and refrigerant pressures and temperatures. Air flow rate and temperature information allowed the cooling capacity to be measured. The power consumption of the pump and compressor used to circulate the working fluids was measured so that COP could be determined. Modeling results were validated with experimental findings. The emphasis of modeling and experiments was to determine the effect of operational parameters on system performance. The loading of ionic liquid and carbon dioxide, along with valve opening and compressor speed, was found to dramatically alter the operating pressures. The difference and ratio between high and low side pressures directly affected the specific cooling capacity and COP, respectively. While the model had strong agreement with the experimental results, non-idealities to be incorporated in more sophisticated models are identified
- …