6 research outputs found

    Comparison of beam segment versus full plan re-optimization in daily magnetic resonance imaging-guided online-adaptive radiotherapy

    Get PDF
    The optimal approach for magnetic resonance imaging-guided online adaptive radiotherapy is currently unknown and needs to consider patient on-couch time constraints. The aim of this study was to compare two different plan optimization approaches. The comparison was performed in 238 clinically applied online-adapted treatment plans from 55 patients, in which the approach of re-optimization was selected based on the physician's choice. For 33 patients where both optimization approaches were used at least once, the median treatment planning dose metrics of both target and organ at risk differed less than 1%. Therefore, we concluded that beam segment weight optimization was chosen adequately for most patients without compromising plan quality

    Treatment plan quality during online adaptive re-planning

    Full text link
    Background Online adaptive radiotherapy is intended to prevent plan degradation caused by inter-fractional tumor volume and shape changes, but time limitations make online re-planning challenging. The aim of this study was to compare the quality of online-adapted plans to their respective reference treatment plans. Methods Fifty-two patients treated on a ViewRay MRIdian Linac were included in this retrospective study. In total 238 online-adapted plans were analyzed, which were optimized with either changing of the segment weights (n = 85) or full re-optimization (n = 153). Five different treatment sites were evaluated: prostate, abdomen, liver, lung and pelvis. Dosimetric parameters of gross tumor volume (GTV), planning target volume (PTV), 2 cm ring around the PTV and organs at risk (OARs) were considered. The Wilcoxon signed-rank test was used to assess differences between online-adapted and reference treatment plans, p < 0.05 was considered significant. Results The average duration of the online adaptation, consisting of contour editing, plan optimization and quality assurance (QA), was 24 ± 6 min. The GTV was slightly larger (average ± SD: 1.9% ± 9.0%) in the adapted plans than in the reference plans (p < 0.001). GTV-D95% exhibited no significant changes when considering all plans, but GTV-D2% increased by 0.40% ± 1.5% on average (p < 0.001). There was a very small yet significant decrease in GTV-coverage for the abdomen plans. The ring Dmean increased on average by 1.0% ± 3.6% considering all plans (p < 0.001). There was a significant reduction of the dose to the rectum of 4.7% ± 16% on average (p < 0.001) for prostate plans. Conclusions Dosimetric quality of online-adapted plans was comparable to reference treatment plans and OAR dose was either comparable or decreased, depending on treatment site. However, dose spillage was slightly increased

    Dosimetric and geometric end-to-end accuracy of a magnetic resonance guided linear accelerator

    Get PDF
    The introduction of real-time imaging by magnetic resonance guided linear accelerators (MR-Linacs) enabled adaptive treatments and gating on the tumor position. Different end-to-end tests monitored the accuracy of our MR-Linac during the first year of clinical operation. We report on the stability of these tests covering a static, adaptive and gating workflow. Film measurements showed gamma passing rates of 96.4% ± 3.4% for the static tests (five measurements) and for the two adaptive tests 98.9% and 99.99%, respectively (criterion 2%/2mm). The gated point dose measurements in the breathing phantom were 2.7% lower than in the static phantom

    Distance to isocenter is not associated with an increased risk for local failure in LINAC-based single-isocenter SRS or SRT for multiple brain metastases

    Full text link
    PURPOSE To evaluate the impact of the distance between treatment isocenter and brain metastases on local failure in patients treated with a frameless linear-accelerator-based single-isocenter volumetric modulated arc (VMAT) SRS/SRT for multiple brain metastases. METHODS AND MATERIALS Patients treated with SRT for brain metastases (BM) between April 2014 and May 2019 were included in this retrospective study. BM treated with a single-isocenter multiple-target (SIMT) SRT were evaluated for local recurrence-free intervals in dependency to their distance to the treatment isocenter. A Cox-regression model was used to investigate different predictor variables for local failure. Results were compared to patients treated with a single-isocenter-single-target (SIST) approach. RESULTS In total 315 patients with a cumulative number of 1087 BM were analyzed in this study of which 140 patients and 708 BM were treated with SIMT SRS/SRT. Median follow-up after treatment was 13.9 months for SIMT approach and 11.9 months for SIST approach. One-year freedom from local recurrence was 87% and 94% in the SIST and SIMT group, respectively. Median distance to isocenter (DTI) was 4.7 cm (range 0.2-10.5) in the SIMT group. Local recurrence-free interval was not associated with the distance to the isocenter in univariable or multivariable Cox-regression analysis. Multivariable analysis revealed only volume as an independent significant predictor for local failure (p-value <0.05). CONCLUSION SRS/SRT using single-isocenter VMAT for multiple targets achieved high local metastases control rates irrespective of distance to the isocenter, supporting efficacy of single-isocenter stereotactic radiation therapy for multiple brain metastases