50 research outputs found

    Comparison of different surgical approaches for pediatric cataracts: complications and rates of additional surgery during long-term follow-up

    Get PDF
    OBJECTIVES: To compare long-term postoperative complications of pediatric cataract surgery with primary intraocular lens (IOL) implantation associated with posterior capsulotomy (PC) and anterior vitrectomy (AV) between patients treated with a corneal or pars plicata/pars plana approach. METHODS: Children who underwent cataract surgery with in-the-bag primary IOL implantation were divided into two groups according to PC and AV surgical approach: a corneal approach (group 1) and a pars plicata/pars plana approach (group 2). Only patients with a follow-up duration of more than two years were included. Longterm surgical outcomes were retrospectively reported. RESULTS: The mean follow-up period was 10.00±3.13 years. No cases of glaucoma or retinal detachment were reported. The mean age at surgery was 34.57±22.66 months. Forty-six children were included (27 eyes in group 1 and 29 eyes in group 2). The most frequent postoperative complication was corectopia, followed by visual axis opacification. Both complications occurred more frequently in group 1 (po0.001). After cataract surgery, the rate of additional surgeries in group 1 was 51.9%, while in group 2, the rate was 27.6% (p=0.1132). CONCLUSION: The pars plicata/pars plana approach with PC and vitrectomy with primary in-the-bag IOL implantation for pediatric cataracts is a safe procedure

    Role of Optical Coherence Tomography on Corneal Surface Laser Ablation

    Get PDF
    This paper focuses on reviewing the roles of optical coherence tomography (OCT) on corneal surface laser ablation procedures. OCT is an optical imaging modality that uses low-coherence interferometry to provide noninvasive cross-sectional imaging of tissue microstructure in vivo. There are two types of OCTs, each with transverse and axial spatial resolutions of a few micrometers: the time-domain and the fourier-domain OCTs. Both have been increasingly used by refractive surgeons and have specific advantages. Which of the current imaging instruments is a better choice depends on the specific application. in laser in situ keratomileusis (LASIK) and in excimer laser phototherapeutic keratectomy (PTK), OCT can be used to assess corneal characteristics and guide treatment decisions. OCT accurately measures central corneal thickness, evaluates the regularity of LASIK flaps, and quantifies flap and residual stromal bed thickness. When evaluating the ablation depth accuracy by subtracting preoperative from postoperative measurements, OCT pachymetry correlates well with laser ablation settings. in addition, OCT can be used to provide precise information on the morphology and depth of corneal pathologic abnormalities, such as corneal degenerations, dystrophies, and opacities, correlating with histopathologic findings.Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH 44114 USAAltino Ventura Fdn, Dept Ophthalmol, Recife, PE, BrazilUniv Fed Rio de Janeiro, Dept Ophthalmol, Rio de Janeiro, RJ, BrazilUniversidade Federal de São Paulo, Dept Ophthalmol, São Paulo, SP, BrazilUniversidade Federal de São Paulo, Dept Ophthalmol, São Paulo, SP, BrazilWeb of Scienc

    The effect of subconjunctival bevacizumab on corneal neovascularization, inflammation and re-epithelization in a rabbit model

    Get PDF
    PURPOSE: To evaluate the use of subconjunctival bevacizumab on corneal neovascularization in an experimental rabbit model for its effect on vessel extension, inflammation, and corneal epithelialization. METHODS: In this prospective, randomized, blinded, experimental study, 20 rabbits were submitted to a chemical trauma with sodium hydroxide and subsequently divided into two groups. The experimental group received a subconjunctival injection of bevacizumab (0.15 m; 3.75 mg), and the control group received an injection of 0.15 ml saline solution. After 14 days, two blinded digital photograph analyses were conducted to evaluate the inflammation/diameter of the vessels according to pre-established criteria. A histopathological analysis of the cornea evaluated the state of the epithelium and the number of polymorphonuclear cells. RESULTS: A concordance analysis using Kappa's statistic showed a satisfactory level of agreement between the two blinded digital photography analyses. The neovascular vessel length was greater in the control group (p<0.01) than in the study group. However, the histopathological examination revealed no statistically significant differences between the groups in terms of the state of the epithelium and the number of polymorphonuclear cells. CONCLUSIONS: Subconjunctival bevacizumab inhibited neovascularization in the rabbit cornea. However, this drug was not effective at reducing inflammation. The drug did not induce persistent corneal epithelial defects

    Posterior Capsule Opacification after Cataract Surgery in Children Over Five Years of Age with Square-edge Hydrophobic versus Hydrophilic Acrylic Intraocular Lenses: A Prospective Randomized Study

    Get PDF
    OBJECTIVE: To compare the effects of hydrophobic and hydrophilic materials in square-edged acrylic intraocular lenses (IOLs) on the development of posterior capsule opacification (PCO) after pediatric cataract surgery. METHODS: Patients were randomly assigned to group 1 (hydrophobic acrylic square-edged IOLs; 13 eyes) or group 2 (hydrophilic acrylic square-edged IOLs; 13 eyes). The study evaluated PCO rates using Evaluation of Posterior Capsule Opacification (EPCO) 2000 software at one, three, six and 12 months postoperatively. Postoperative measurements also included corrected distance visual acuity (CDVA), neodymium:yttrium-aluminum-garnet (Nd:YAG) capsulotomy and postoperative complications other than PCO. RESULTS: Both groups had significant increases in PCO rates after one year. Comparison of the groups showed no significant differences in the EPCO scores at three (group 1, 0.007±0.016 vs group 2, 0.008±0.014; p=0.830), six (group 1, 0.062±0.103 vs group 2, 0.021±0.023; p=0.184), or twelve months postoperatively (group 1, 0.200±0.193 vs group 2, 0.192±0.138; p=0.902). We also found no significant group differences regarding the change (delta, D) in EPCO scores between three and six months (group 1, 0.055±0.09 vs group 2, 0.013±0.02; p=0.113) or between six and twelve months postoperatively (group 1, 0.139±0.14 vs group 2, 0.171±0.14; p=0.567). Twenty-three percent of patients required Nd:YAG capsulotomy at the twelve-month visit. CONCLUSIONS: No differences in PCO rates were found between hydrophobic and hydrophilic acrylic squareedged IOLs in children between five and twelve years of age at one year of follow-up

    Influence of aspheric intraocular lens on frequency doubling technology and contrast sensitivity: a fellow eye study

    Full text link
    Purpose: To evaluate whether implantation of an aspheric intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery and, therefore, changes on frequency-doubling technology (FDT) testing. Methods: The present prospective clinical study enrolled 25 patients with bilateral cataract (50 eyes), who randomly received either an aspheric (Akreos AO) or a spherical (Akreos Fit) IOL in one eye and the other IOL in the second eye. Assessment 12 months postoperatively included photopic and mesopic contrast sensitivity testing. Higher-order aberrations (HOAs) were computed. FDT testing was divided into four areas to evaluate the variation of the values at different points. The median values of the local pattern thresholds (median area contrast sensitivity [MACS]) obtained with that division were calculated. Results: The Akreos AO group obtained statistically significantly lower values of HOAs and spherical aberration compared with the Akreos Fit group. There was a statistically significant between-group difference in contrast sensitivity under mesopic conditions at all spatial frequencies. No statistically significant differences were observed in mean deviation and pattern standard deviation. The aspheric IOL exhibited higher MACS in all areas, although a statistically significant difference was reached only in the 20-degree field area (P=0.043). Conclusion: Aspheric IOLs significantly reduced spherical aberration and HOAs, improving mesopic contrast sensitivity. Although there was a trend toward slightly improved FDT in the aspheric IOL group, it was not statistically significant

    Ocular findings in patients with systemic sclerosis

    Get PDF
    OBJECTIVE: To evaluate the frequency and characteristics of ocular manifestations in outpatients with systemic sclerosis. METHODS: In this cross-sectional study, 45 patients with systemic sclerosis were enrolled. Data regarding demographics, disease duration and subtype, age at diagnosis, nailfold capillaroscopic pattern and autoantibody profile were collected, and a full ophthalmic examination was conducted. Parametric (Student's t-test) and nonparametric (Mann-Whitney U test) tests were used to compare continuous variables. Fisher's exact test was used to compare categorical data. P values < 0.05 were considered significant. RESULTS: Twenty-three subjects (51.1%) had eyelid skin changes; 22 (48.9%) had keratoconjunctivitis sicca, 19 (42.2%) had cataracts, 13 (28.9%) had retinal microvascular abnormalities and 6 (13.3%) had glaucoma. Eyelid skin changes were more frequent in patients with the diffuse subtype of systemic sclerosis and were associated with a younger age and an earlier age at diagnosis. Cataracts were presumed to be age-related and secondary to corticosteroid treatment. There was no association between demographic, clinical or serological data and keratoconjunctivitis sicca. The retinal microvascular abnormalities were indistinguishable from those related to systemic hypertension and were associated with an older age and a severe capillaroscopic pattern. CONCLUSIONS: Eyelid skin abnormalities and keratoconjunctivitis sicca were the most common ocular findings related to systemic sclerosis. Some demographic and clinical data were associated with some ophthalmic features and not with others, showing that the ocular manifestations of systemic sclerosis are characterized by heterogeneity and reflect the differences in the implicated pathophysiological mechanisms

    Modulation transfer function and optical quality after bilateral implantation of a+3.00 D versus a+4.00 D multifocal intraocular lens

    Get PDF
    PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add

    Refractive Surgical Problem

    No full text
    corecore