117 research outputs found

    Total lung capacity by plethysmography and high-resolution computed tomography in COPD

    Get PDF
    Jamie L Garfield, Nathaniel Marchetti, John P Gaughan, Robert M Steiner, Gerard J CrinerDepartment of Pulmonary and Critical Care Medicine and Department of Radiology, Temple University School of Medicine, Philadelphia, Pennsylvania, USAAim: To characterize and compare total lung capacity (TLC) measured by plethysmography with high-resolution computed tomography (HRCT), and to identify variables that predict the difference between the two modalities.Methods: Fifty-nine consecutive patients referred for the evaluation of COPD were retrospectively reviewed. Patients underwent full pulmonary function testing and HRCT within 3 months. TLC was obtained by plethysmography as per American Thoracic Society/European Respiratory Society standards and by HRCT using custom software on 0.75 and 5 mm thick contiguous slices performed at full inspiration (TLC).Results: TLC measured by plethysmography correlated with TLC measured by inspiratory HRCT (r = 0.92, P < 0.01). TLC measured by plethysmography was larger than that determined by inspiratory HRCT in most patients (mean of 6.46 ± 1.28 L and 5.34 ± 1.20 L respectively, P < 0.05). TLC measured by both plethysmography and HRCT correlated significantly with indices of airflow obstruction (forced expiratory volume in 1 second/forced vital capacity [FVC] and FVC%), static lung volumes (residual volume, percent predicted [RV%], total lung capacity, percent predicted [TLC%], functional residual capacity, percent predicted [FRC%], and inspiratory capacity, percent predicted), and percent emphysema. TLC by plethysmography and HRCT both demonstrated significant inverse correlations with diffusion impairment. The absolute difference between TLC measured by plethysmography and HRCT increased as RV%, TLC%, and FRC% increased. Gas trapping (RV% and FRC%) independently predicted the difference in TLC between plethysmography and HRCT.Conclusion: In COPD, TLC by plethysmography can be up to 2 L greater than inspiratory HRCT. Gas trapping independently predicts patients for whom TLC by plethysmography differs significantly from HRCT.Keywords: lung capacity, plethysmography, high-resolution computed tomography, gas trapping, lung volume measurement error

    History and Future Perspectives on the Discipline of Quantitative Systems Pharmacology Modeling and Its Applications

    Get PDF
    Mathematical biology and pharmacology models have a long and rich history in the fields of medicine and physiology, impacting our understanding of disease mechanisms and the development of novel therapeutics. With an increased focus on the pharmacology application of system models and the advances in data science spanning mechanistic and empirical approaches, there is a significant opportunity and promise to leverage these advancements to enhance the development and application of the systems pharmacology field. In this paper, we will review milestones in the evolution of mathematical biology and pharmacology models, highlight some of the gaps and challenges in developing and applying systems pharmacology models, and provide a vision for an integrated strategy that leverages advances in adjacent fields to overcome these challenges

    Relationship between quantitative CT metrics and health status and BODE in chronic obstructive pulmonary disease

    Full text link
    Background The value of quantitative CT (QCT) to identify chronic obstructive pulmonary disease (COPD) phenotypes is increasingly appreciated. The authors hypothesised that QCT-defined emphysema and airway abnormalities relate to St George’s Respiratory Questionnaire (SGRQ) and Body-Mass Index, Airflow Obstruction, Dyspnea and Exercise Capacity Index (BODE). Methods 1200 COPDGene subjects meeting Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for COPD with QCT analysis were included. Total lung emphysema was measured using the density mask technique with a 950 Hounsfield unit threshold. An automated programme measured mean wall thickness (WT), wall area percentage (WA%) and 10 mm lumenal perimeter (pi10) in six segmental bronchi. Separate multivariate analyses examined the relative influence of airway measures and emphysema on SGRQ and BODE. Results In separate models predicting SGRQ score, a 1 unit SD increase in each airway measure predicted higher SGRQ scores (for WT, 1.90 points higher, p=0.002; for WA%, 1.52 points higher, p=0.02; for pi10, 2.83 points higher p<0.001). The comparable increase in SGRQ for a 1 unit SD increase in emphysema percentage in these models was relatively weaker, significant only in the pi10 model (for emphysema percentage, 1.45 points higher, p=0.01). In separate models predicting BODE, a 1 unit SD increase in each airway measure predicted higher BODE scores (for WT, 1.07-fold increase, p<0.001; for WA%, 1.20-fold increase, p<0.001; for pi10, 1.16-fold increase, p<0.001). In these models, emphysema more strongly influenced BODE (range 1.24-1.26-fold increase, p<0.001). Conclusion Emphysema and airway disease both relate to clinically important parameters. The relative influence of airway disease is greater for SGRQ; the relative influence of emphysema is greater for BODE.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/91946/1/2012 Thorax Relationship between quantitative CT metrics and health status and BODE in chronic obstructive pulmonary disease.pd

    Paired inspiratory-expiratory chest CT scans to assess for small airways disease in COPD

    Get PDF
    Background: Gas trapping quantified on chest CT scans has been proposed as a surrogate for small airway disease in COPD. We sought to determine if measurements using paired inspiratory and expiratory CT scans may be better able to separate gas trapping due to emphysema from gas trapping due to small airway disease. Methods: Smokers with and without COPD from the COPDGene Study underwent inspiratory and expiratory chest CT scans. Emphysema was quantified by the percent of lung with attenuation < −950HU on inspiratory CT. Four gas trapping measures were defined: (1) Exp−856, the percent of lung < −856HU on expiratory imaging; (2) E/I MLA, the ratio of expiratory to inspiratory mean lung attenuation; (3) RVC856-950, the difference between expiratory and inspiratory lung volumes with attenuation between −856 and −950 HU; and (4) Residuals from the regression of Exp−856 on percent emphysema. Results: In 8517 subjects with complete data, Exp−856 was highly correlated with emphysema. The measures based on paired inspiratory and expiratory CT scans were less strongly correlated with emphysema. Exp−856, E/I MLA and RVC856-950 were predictive of spirometry, exercise capacity and quality of life in all subjects and in subjects without emphysema. In subjects with severe emphysema, E/I MLA and RVC856-950 showed the highest correlations with clinical variables. Conclusions: Quantitative measures based on paired inspiratory and expiratory chest CT scans can be used as markers of small airway disease in smokers with and without COPD, but this will require that future studies acquire both inspiratory and expiratory CT scans

    Paired inspiratory-expiratory chest CT scans to assess for small airways disease in COPD

    Full text link
    Abstract Background Gas trapping quantified on chest CT scans has been proposed as a surrogate for small airway disease in COPD. We sought to determine if measurements using paired inspiratory and expiratory CT scans may be better able to separate gas trapping due to emphysema from gas trapping due to small airway disease. Methods Smokers with and without COPD from the COPDGene Study underwent inspiratory and expiratory chest CT scans. Emphysema was quantified by the percent of lung with attenuation < −950HU on inspiratory CT. Four gas trapping measures were defined: (1) Exp−856, the percent of lung < −856HU on expiratory imaging; (2) E/I MLA, the ratio of expiratory to inspiratory mean lung attenuation; (3) RVC856-950, the difference between expiratory and inspiratory lung volumes with attenuation between −856 and −950 HU; and (4) Residuals from the regression of Exp−856 on percent emphysema. Results In 8517 subjects with complete data, Exp−856 was highly correlated with emphysema. The measures based on paired inspiratory and expiratory CT scans were less strongly correlated with emphysema. Exp−856, E/I MLA and RVC856-950 were predictive of spirometry, exercise capacity and quality of life in all subjects and in subjects without emphysema. In subjects with severe emphysema, E/I MLA and RVC856-950 showed the highest correlations with clinical variables. Conclusions Quantitative measures based on paired inspiratory and expiratory chest CT scans can be used as markers of small airway disease in smokers with and without COPD, but this will require that future studies acquire both inspiratory and expiratory CT scans.http://deepblue.lib.umich.edu/bitstream/2027.42/134586/1/12931_2012_Article_1346.pd

    Effect of Zephyr Endobronchial Valves on Dyspnea, Activity Levels, and Quality of Life at One Year Results from a Randomized Clinical Trial

    Get PDF
    Rationale: Bronchoscopic lung volume reduction with Zephyr Valves improves lung function, exercise tolerance, and quality of life of patients with hyperinflated emphysema and little to no collateral ventilation. Objectives: Post hoc analysis of patient-reported outcomes (PROs), including multidimensional measures of dyspnea, activity, and quality of life, in the LIBERATE (Lung Function Improvement after Bronchoscopic Lung Volume Reduction with Pulmonx Endobronchial Valves used in Treatment of Emphysema) study are reported. Methods: A total of 190 patients with severe heterogeneous emphysema and little to no collateral ventilation in the target lobe were randomized 2:1 to the Zephyr Valve or standard of care. Changes in PROs at 12 months in the two groups were compared: dyspnea with the Transitional Dyspnea Index (TDI), focal score; the Chronic Obstructive Pulmonary Disease Assessment Test (CAT; breathlessness on hill/stairs); Borg; the EXAcerbations of Chronic pulmonary disease Tool-PRO, dyspnea domain; activity with the TDI, magnitude of task/effort/functional impairment, CAT (limited activities), and the St. George's Respiratory Questionnaire (SGRQ), activity domain; and psychosocial status with the SGRQ, impacts domain, and CAT (confidence and energy). Results: At 12 months, patients using the Zephyr Valve achieved statistically significant and clinically meaningful improvements in the SGRQ; CAT; and the TDI, focal score, compared with standard of care. Improvements in the SGRQ were driven by the impacts and activity domains (P, 0.05 and P, 0.001, respectively). Reduction in CAT was through improvements in breathlessness (P, 0.05), energy level (P, 0.05), activities (P, 0.001), and increased confidence when leaving home (P, 0.05). The TDI measures of effort, task, and functional impairment were uniformly improved (P, 0.001). The EXAcerbations of Chronic Pulmonary Disease Tool (EXACT)-PRO, dyspnea domain, was significantly improved in the Zephyr Valve group. Improvements correlated with changes in residual volume and residual volume/TLC ratio. Conclusions: Patients with severe hyperinflated emphysema achieving lung volume reductions with Zephyr Valves experience improvements in multidimensional scores for breathlessness, activity, and psychosocial parameters out to at least 12 months

    Distinct functional neutrophil phenotypes in sepsis patients correlate with disease severity

    Get PDF
    PurposeSepsis is a clinical syndrome defined as life-threatening organ dysfunction caused by a dysregulated host response to infection. Sepsis is a highly heterogeneous syndrome with distinct phenotypes that impact immune function and response to infection. To develop targeted therapeutics, immunophenotyping is needed to identify distinct functional phenotypes of immune cells. In this study, we utilized our Organ-on-Chip assay to categorize sepsis patients into distinct phenotypes using patient data, neutrophil functional analysis, and proteomics.MethodsFollowing informed consent, neutrophils and plasma were isolated from sepsis patients in the Temple University Hospital ICU (n=45) and healthy control donors (n=7). Human lung microvascular endothelial cells (HLMVEC) were cultured in the Organ-on-Chip and treated with buffer or cytomix ((TNF/IL-1ÎČ/IFNÎł). Neutrophil adhesion and migration across HLMVEC in the Organ-on-Chip were used to categorize functional neutrophil phenotypes. Quantitative label-free global proteomics was performed on neutrophils to identify differentially expressed proteins. Plasma levels of sepsis biomarkers and neutrophil extracellular traps (NETs) were determined by ELISA.ResultsWe identified three functional phenotypes in critically ill ICU sepsis patients based on ex vivo neutrophil adhesion and migration patterns. The phenotypes were classified as: Hyperimmune characterized by enhanced neutrophil adhesion and migration, Hypoimmune that was unresponsive to stimulation, and Hybrid with increased adhesion but blunted migration. These functional phenotypes were associated with distinct proteomic signatures and differentiated sepsis patients by important clinical parameters related to disease severity. The Hyperimmune group demonstrated higher oxygen requirements, increased mechanical ventilation, and longer ICU length of stay compared to the Hypoimmune and Hybrid groups. Patients with the Hyperimmune neutrophil phenotype had significantly increased circulating neutrophils and elevated plasma levels NETs.ConclusionNeutrophils and NETs play a critical role in vascular barrier dysfunction in sepsis and elevated NETs may be a key biomarker identifying the Hyperimmune group. Our results establish significant associations between specific neutrophil functional phenotypes and disease severity and identify important functional parameters in sepsis pathophysiology that may provide a new approach to classify sepsis patients for specific therapeutic interventions

    Leading-order QCD Analysis of Neutrino-Induced Dimuon Events

    Get PDF
    The results of a leading-order QCD analysis of neutrino-induced charm production are presented. They are based on a sample of 4111 \numu- and 871 \anumu-induced opposite-sign dimuon events with EÎŒ1,EÎŒ2>6 GeVE_{\mu 1},E_{\mu 2} > 6~{\rm GeV}, 355.5 GeV235 5.5\,{\rm GeV^2}, observed in the CHARM~II detector exposed to the CERN wideband neutrino and antineutrino beams. The analysis yields the value of \linebreak the charm quark mass mc=1.79±0.38 GeV/c2m_c=1.79\pm0.38\,{\rm GeV}/c^2 and the Cabibbo--Kobayashi--Maskawa matrix element ∣Vcd∣=0.219±0.016|V_{cd}|=0.219\pm0.016. The strange quark content of the nucleon is found to be suppressed with respect to non-strange sea quarks by a factor Îș=0.39±0.09\kappa =0.39\pm0.09

    Experimental search for muonic photons

    Get PDF
    We report new limits on the production of muonic photons in the CERN neutrino beam. The results are based on the analysis of neutrino production of dimuons in the CHARM II detector. A 90%90\% CL limit on the coupling constant of muonic photons, αΌ/α<(1.5Ă·3.2)×10−6\alpha_{\mu} / \alpha < (1.5 \div 3.2) \times10^{-6} is derived for a muon neutrino mass in the range mΜΌ=(10−20Ă·105)m_{\nu_{\mu}} = (10^{-20} \div 10^5) eV. This improves the limit obtained from a precision measurement of the anomalous magnetic moment of the muon (g−2)ÎŒ(g-2)_\mu by a factor from 8 to 4
    • 

    corecore