77 research outputs found
Circulation characteristics of a monsoon depression during BOBMEX-99 using high-resolution analysis
The skill and efficiency of a numerical model mostly varies with the quality of initial values, accuracy on parameterization of physical processes and horizontal and vertical resolution of the model. Commonly used low-resolution reanalyses are hardly able to capture the prominent features associated with organized convective processes in a monsoon depression. The objective is to prepare improved high-resolution analysis by the use of MM5 modelling system developed by the Pennsylvania State University/National Center for Atmospheric Research (PSU/NCAR). It requires the objective comparison of high and low-resolution analysis datasets in assessing the specific convective features of a monsoon depression. For this purpose, reanalysis datasets of NCAR/NCEP (National Center for Atmospheric Research/National Centers for Environmental Prediction) at a horizontal resolution of 2.5° (latitude/longitude) have been used as first guess in the objective analysis scheme. The additional asynoptic datasets obtained during BOBMEX-99 are utilized within the assimilation process. Cloud Motion Wind (CMW) data of METEOSAT satellite and SSM/I surface wind data are included for the improvement of derived analysis. The multiquadric (MQD) interpolation technique is selected and applied for meteorological objective analysis at a horizontal resolution of 30 km. After a successful inclusion of additional data, the resulting reanalysis is able to produce the structure of convective organization as well as prominent synoptic features associated with monsoon depression. Comparison and error verifications have been done with the help of available upper-air station data. The objective verification reveals the efficiency of the analysis scheme
Validation of 3D neutronic-thermalhydraulic coupled codes RELAP5/PARCSv2.7 and TRACEv5.0P3/PARCSv3.0 against a PWR control rod drop transient
[EN] In nuclear safety field, neutronic and thermalhydraulic codes performance is an important issue. New capabilities implementation, as well as models and tools improvements are a significant part of the community effort in looking for better Nuclear Power Plants (NPP) designs. A procedure to analyze the PWR response to local deviations on neutronic or thermalhydraulic parameters is being developed. This procedure includes the simulation of Incore and Excore neutron flux detectors signals. A control rod drop real plant transient is used to validate the used codes and their new capabilities. Cross-section data are obtained by means of the SIMTAB methodology. Detailed thermalhydraulic models were developed: RELAP5 and TRACE models simulate three different azimuthal zones. Besides, TRACE model is performed with a fully 3D core, thus, the cross-flow can be obtained. A cartesian vessel represents the fuel assemblies and a cylindrical vessel the bypass and downcomer. Simulated detectors signals are obtained and compared with the real data collected during a control rod drop trial at a PWR NPP and also with data obtained with SIMULATE-3K code.The authors would like to acknowledge the economic support provided by Centrales Nucleares Almaraz-Trillo (CNAT) and IBERDROLA Ingeniería y Construcción (Iberinco) for the realization of this work, and express their great appreciation to Arturo López, Juan Antonio Bermejo and Alberto Ortego for their valuable collaboration and their willingness to develop this work. This work has also been supported by the Spanish Ministerio de Economía y Competitividad, through the projects NUC-MULTPHYS (ENE2012-34585) and VALIUN-3D (ENE2011-22823), and the Generalitat Valenciana (GVA), through the project PROMETEO II/2014/008.Garcia-Fenoll, M.; Mesado Melia, C.; Barrachina, T.; Miró Herrero, R.; Verdú Martín, GJ.; Bermejo, JA.; López, A.... (2017). Validation of 3D neutronic-thermalhydraulic coupled codes RELAP5/PARCSv2.7 and TRACEv5.0P3/PARCSv3.0 against a PWR control rod drop transient. Journal of Nuclear Science and Technology. 54(8):908-919. https://doi.org/10.1080/00223131.2017.1329035S90891954
Recommended from our members
Comparative genomics of European Avian Pathogenic E. coli (APEC)
Background
Avian pathogenic Escherichia coli (APEC) causes colibacillosis, which results in significant economic losses to the poultry industry worldwide. However, the diversity between isolates remains poorly understood. Here, a total of 272 APEC isolates collected from the United Kingdom (UK), Italy and Germany were characterised using multiplex polymerase chain reactions (PCRs) targeting 22 equally weighted factors covering virulence genes, R-type and phylogroup. Following these analysis, 95 of the selected strains were further analysed using Whole Genome Sequencing (WGS).
Results
The most prevalent phylogroups were B2 (47%) and A1 (22%), although there were national differences with Germany presenting group B2 (35.3%), Italy presenting group A1 (53.3%) and UK presenting group B2 (56.1%) as the most prevalent. R-type R1 was the most frequent type (55%) among APEC, but multiple R-types were also frequent (26.8%). Following compilation of all the PCR data which covered a total of 15 virulence genes, it was possible to build a similarity tree using each PCR result unweighted to produce 9 distinct groups. The average number of virulence genes was 6-8 per isolate, but no positive association was found between phylogroup and number or type of virulence genes. A total of 95 isolates representing each of these 9 groupings were genome sequenced and analysed for in silico serotype, Multilocus Sequence Typing (MLST), and antimicrobial resistance (AMR). The UK isolates showed the greatest variability in terms of serotype and MLST compared with German and Italian isolates, whereas the lowest prevalence of AMR was found for German isolates. Similarity trees were compiled using sequencing data and notably single nucleotide polymorphism data generated ten distinct geno-groups. The frequency of geno-groups across Europe comprised 26.3% belonging to Group 8 representing serogroups O2, O4, O18 and MLST types ST95, ST140, ST141, ST428, ST1618 and others, 18.9% belonging to Group 1 (serogroups O78 and MLST types ST23, ST2230), 15.8% belonging to Group 10 (serogroups O8, O45, O91, O125ab and variable MLST types), 14.7% belonging to Group 7 (serogroups O4, O24, O35, O53, O161 and MLST type ST117) and 13.7% belonging to Group 9 (serogroups O1, O16, O181 and others and MLST types ST10, ST48 and others). The other groups (2, 3, 4, 5 and 6) each contained relatively few strains.
However, for some of the genogroups (e.g. groups 6 and 7) partial overlap with SNPs grouping and PCR grouping (matching PCR groups 8 (13 isolates on 22) and 1 (14 isolates on 16) were observable). However, it was not possible to obtain a clear correlation between genogroups and unweighted PCR groupings. This may be due to the genome plasticity of E. coli that enables strains to carry the same virulence factors even if the overall genotype is substantially different.
Conclusions
The conclusion to be drawn from the lack of correlations is that firstly, APEC are very diverse and secondly, it is not possible to rely on any one or more basic molecular or phenotypic tests to define APEC with clarity, reaffirming the need for whole genome analysis approaches which we describe here.
This study highlights the presence of previously unreported serotypes and MLSTs for APEC in Europe. Moreover, it is a first step on a cautious reconsideration of the merits of classical identification criteria such as R typing, phylogrouping and serotyping
Free abdominal fluid without obvious solid organ injury upon CT imaging: an actual problem or simply over-diagnosing?
Whereas a non-operative approach for hemodynamically stable patients with free intraabdominal fluid in the presence of solid organ injury is generally accepted, the presence of free fluid in the abdomen without evidence of solid organ injury not only presents a challenge for the treating emergency physician but also for the surgeon in charge. Despite recent advances in imaging modalities, with multi-detector computed tomography (CT) (with or without contrast agent) usually the imaging method of choice, diagnosis and interpretation of the results remains difficult. While some studies conclude that CT is highly accurate and relatively specific at diagnosing mesenteric and hollow viscus injury, others studies deem CT to be unreliable. These differences may in part be due to the experience and the interpretation of the radiologist and/or the treating physician or surgeon
Novel Extraction Method for Source and Drain Series Resistances in Silicon Nanowire Metal-Oxide-Semiconductor Field-Effect-Transistors Based on Radio-Frequency Analysis
In this work, we present a novel analytical method based on radio-frequency (RF) analysis for the accurate and reliable extraction of source and drain (S/D) series resistances in silicon nanowire (SNW) metal-oxide-semiconductor field-effect transistors (MOSFETs). The proposed method provides decomposed RF model equations for the gate-bias-independent off-state and gate-bias-dependent on-state components from both Y-and Z-parameters. The validity of our extraction method for S/D series resistances in SNW MOSFETs has been carefully tested in comparison with that of a previously reported method as well as with the physical three-dimensional (3D) device simulation. The schematically modeled Y-and Z-parameters have demonstrated excellent agreement with the numerical 3D device simulation results for various SNW MOSFET structures up to the 100 GHz frequency regime.close0
Assessment of Dynamic Pairwise Wake Vortex Separations for Approach and Landing at Vienna Airport
The Wake Vortex Prediction Sytem WSVS (WirbelSchleppenVorhersageSystem) has been developed to tactially increase Airport capacity by employing dynamically adjusted aircraft Separation for Approach and landing without compromising safety. For this conditions and the resulting wake vortex behaviour
- …