24 research outputs found

    Ability to remotely monitor atrial high-rate episodes using a single-chamber implantable cardioverter-defibrillator with a floating atrial sensing dipole

    Get PDF
    Aims To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…&lt;1 h, 1 h…&lt;24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. Methods In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in and results each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…&lt;1 h, 99.6% (253/254) for episodes 1 h…&lt;24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/ 610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA 2DS 2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. Conclusion A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.</p

    Physical activity measured by implanted devices predicts atrial arrhythmias and patient outcome: Results of IMPLANTED (Italian Multicentre Observational Registry on Patients With Implantable Devices Remotely Monitored)

    Get PDF
    Background--To determine whether daily physical activity (PA), as measured by implanted devices (through accelerometer sensor), was related to the risk of developing atrial arrhythmias during long-term follow-up in a population of heart failure (HF) patients with an implantable cardioverter defibrillator (ICD). Methods and Results--The study population was divided into 2 equally sized groups (PA cutoff point: 3.5 h/d) according to their mean daily PA recorded by the device during the 30- to 60-day period post-ICD implantation. Propensity score matching was used to compare 2 equally sized cohorts with similar characteristics between lower and higher activity patients. The primary end point was time free from the first atrial high-rate episode (AHRE) of duration 656 minutes. Secondary end points were: first AHRE 656 hours, first AHRE 6548 hours, and a combined end point of death or HF hospitalization. Data from 770 patients (65\ub115 years; 66% men; left ventricular ejection fraction 35\ub112%) remotely monitored for a median of 25 months were analyzed. A PA =3.5 h/d was associated with a 38% relative reduction in the risk of AHRE 656 minutes (72-month cumulative survival: 75.0% versus 68.1%; log rank P=0.025), and with a reduction in the risk of AHRE 656 hours, AHRE 6548 hours, and the combined end point of death or HF hospitalization (all P &lt; 0.05). Conclusions--In HF patients with ICD, a low level of daily PA was associated with a higher risk of atrial arrhythmias, regardless of the patients' baseline characteristics. In addition, a lower daily PA predicted death or HF hospitalization

    Insight into contact force local impedance technology for predicting effective pulmonary vein isolation

    Get PDF
    BackgroundHighly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created.ObjectiveWe aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry.MethodsA total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included.ResultsIn all, 13,891 radiofrequency (RF) applications of ≥3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19 Ω vs. 153.0 ± 13 Ω, p &lt; 0.0001 for baseline LI; 22.1 ± 9 Ω vs. 14.4 ± 5 Ω, p &lt; 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was &gt;21 Ω at anterior sites and &gt;18 Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13–0.16, p &lt; 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (−0.22, −0.23 to −0.20, p &lt; 0.0001 for CF; −0.27, −0.29 to −0.26, p &lt; 0.0001 for LI drop).ConclusionAn LI drop &gt;21 Ω at anterior sites and &gt;18 Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT.Clinical trial registrationhttp://clinicaltrials.gov/, identifier: NCT03793998

    Clinically guided pacemaker choice and setting: pacemaker expert programming study

    Get PDF
    The aim of this multicentre, observational, transversal study was to evaluate pacemaker (PM) choice and setting in a large number of patients, in order to understand their relationship with the patients' clinical characteristics

    Assessing access to MRI of patients with magnetic resonance-conditional pacemaker and implantable cardioverter defibrillator systems: the Really ProMRI study design

    No full text
    Background Despite the fact that magnetic resonance (MR)-conditional pacemaker and lead systems have been introduced more than 5 years ago, it is still not clear whether they have actually facilitated the access of pacemaker patients to this important diagnostic tool. Factors limiting MR scans in daily practice in patients with MR-conditional cardiac implantable electronic device (CIED) systems may be related to organizational, cultural and sometimes legal aspects. The Really ProMRI registry is an ongoing survey designed to assess the annual rate of MR examinations in patients with MR-conditional implants, with either pacemakers or implantable cardioverter defibrillators, and to detect the main factors limiting MRI. Methods The primary endpoint of the Really ProMRI registry is to assess the current access to MRI of patients with MR-conditional pacemaker or implantable cardioverter defibrillator systems during normal practice. Data in the literature reported a 17% annual incidence of medical conditions requiring MRI in CIED patients. The Really ProMRI registry has been designed to detect 4.5% absolute difference with an 80% statistical power, by recruiting 600 patients already implanted with MR-conditional CIED implant. Patients will be followed up for 1 year, during which they will be asked to refer any prescription, execution or denial of an MR examination by patient questionnaires and original source documents. Conclusion The ongoing Really ProMRI registry will assess the actual rate of and factors limiting the access to MRI for patients with MR-conditional CIEDs

    Clinically oriented device programming in bradycardia patients: part 1 (sinus node disease). Proposals from AIAC (Italian association of arrhythmology and cardiac pacing)

    No full text
    Modern pacemakers have an increasing number of programable parameters and specific algorithms designed to optimize pacing therapy in relation to the individual characteristics of patients. When choosing the most appropriate pacemaker type and programing, the following variables must be taken into account: the type of bradyarrhythmia at the time of pacemaker implantation; the cardiac chamber requiring pacing, and the percentage of pacing actually needed to correct the rhythm disorder; the possible association of multiple rhythm disturbances and conduction diseases; the evolution of conduction disorders during follow-up. The goals of device programing are to preserve or restore the heart rate response to metabolic and hemodynamic demands; to maintain physiological conduction; to maximize device longevity; to detect, prevent, and treat atrial arrhythmia. In patients with sinus node disease, the optimal pacing mode is DDDR. Based on all the available evidence, in this setting, we consider appropriate the activation of the following algorithms: rate responsive function in patients with chronotropic incompetence; algorithms to maximize intrinsic atrioventricular conduction in the absence of atrioventricular blocks; mode-switch algorithms; algorithms for autoadaptive management of the atrial pacing output; algorithms for the prevention and treatment of atrial tachyarrhythmias in the subgroup of patients with atrial tachyarrhythmias/atrial fibrillation. The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients’ clinical features

    Clinically oriented device programming in bradycardia patients: Part 2 (atrioventricular blocks and neurally mediated syncope). Proposals from AIAC (Italian association of arrhythmology and cardiac pacing)

    No full text
    The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features. In part 2, criteria for pacemaker choice and programming in atrioventricular blocks and neurally mediate syncope are proposed. The atrioventricular blocks can be paroxysmal or persistent, isolated or associated with sinus node disease. Neurally mediated syncope can be related to carotid sinus syndrome or cardioinhibitory vasovagal syncope. In sinus rhythm, with persistent atrioventricular block, we considered appropriate the activation of mode-switch algorithms, and algorithms for auto-adaptive management of the ventricular pacing output. If the atrioventricular block is paroxysmal, in addition to algorithms mentioned above, algorithms to maximize intrinsic atrioventricular conduction should be activated. When sinus node disease is associated with atrioventricular block, the activation of rate-responsive function in patients with chronotropic incompetence is appropriate. In permanent atrial fibrillation with atrioventricular block, algorithms for auto-adaptive management of the ventricular pacing output should be activated. If the atrioventricular block is persistent, the activation of rate-responsive function is appropriate. In carotid sinus syndrome, adequate rate hysteresis should be programmed. In vasovagal syncope, specialized sensing and pacing algorithms designed for reflex syncope prevention should be activated

    Long-term progression of rhythm and conduction disturbances in pacemaker recipients: findings from the Pacemaker Expert Programming study

    No full text
    AIMS: Knowledge of the long-term progression of rhythm disorders requiring pacemaker implantation could have significant implications for the choice of device and its management during follow-up. Accordingly, we conducted an observational study to analyse the long-term progression of rhythm disorders requiring pacemaker implantation. METHODS: This multicentre, observational study enrolled 1810 pacemaker patients (age 71.6\u200a\ub1\u200a13.3 years, men 53.8%) consecutively evaluated during scheduled pacemaker follow-up visits. To evaluate the long-term progression of rhythm disorders, we analysed the patient's rhythm disorders at the time of device implantation and during follow-up. After pacemaker implantation, the rhythm disorders were reassessed and recorded at each scheduled pacemaker follow-up visit, and the spontaneous rhythm was analysed during pacemaker interrogation. RESULTS: During a median follow-up of 61.6 months, we observed a progression of the primary rhythm disorder in 295 patients (16.3%; worsening of the preexisting rhythm disorder in 7.7%; occurrence of a new rhythm disorder added to the preexisting one in 8.6%). Specifically, the cumulative per-year risks of developing the following disorders were: atrioventricular block (AVB) in patients implanted for sinus node disease (SND), 0.3%; permanent atrial fibrillation in SND patients, 2.9%; SND in AVB patients, 0.7%; and persistent AVB in patients implanted for chronic bifascicular block 3.0%. CONCLUSION: Our results revealed that rhythm disorders requiring pacemaker implantation show long-term progression in a significant number of cases. In many cases, the progression is substantial and may require a change in pacing mode

    Effect of fixed-rate vs. Rate-RESPONSIve pacing on exercise capacity in patients with permanent, refractory atrial fibrillation and left ventricular dysfunction treated with atrioventricular junction aBLation and bivEntricular pacing (RESPONSIBLE): A prospective, multicentre, randomized, single-blind study

    Get PDF
    Aims: Atrioventricular junction (AVJ) ablation followed by biventricular pacing is an established strategy for improving symptoms and morbidity in patients with permanent atrial fibrillation (AF), reduced left ventricular ejection fraction (LVEF), and uncontrolled ventricular rate. There is no clear evidence that such patients benefit from rate-responsive (RR) pacing. Methods and results: This prospective, randomized, single-blind, multicentre study was designed as an intra-patient comparison and enrolled 60 patients (age 69.5 \ub1 11.8 years, males 63.3%, NYHA 3.0 \ub10.6) with refractory AF and reduced LVEF (mean 32.4\ub18.3%) treated with AVJ ablation and biventricular pacing. Two 6-minute walking tests (6MWT) were performed 1 week apart: one during VVI 70/min biventricular pacing and the other during VVIR 70-130/min biventricular pacing; patients were randomly and blindly assigned to Group A (n = 29, first 6MWT in VVIR mode) or B (n = 31, first 6MWT in VVI mode). Rate-responsive activation determined an increase of 18.8\ub124.4 m in the distance walked during the 6MWT (P &lt; 0.001). The increase was similar in both groups (P = 0.571). A &gt;5% increase in the distance walked was observed in 76.7% of patients. The increase in the distance walked was linearly correlated with the increase in heart rate recorded during the 6MWT in the VVIR mode (r = 0.54; P &lt; 0.001). Conclusion: In permanent AF patients with uncontrolled rate and reduced LVEF who had undergone AVJ ablation and biventricular pacing, RR pacing yields a significant gain in exercise capacity, which seems to be related to the RR-induced frequency during effort

    Seasonal trend of ventricular arrhythmias in a nationwide remote monitoring database of implantable defibrillators and cardiac resynchronization devices

    No full text
    Background: The occurrence of sustained ventricular arrhythmias (SVA) may be influenced by environmental factors. We aimed to investigate annual periodic trends of SVA from the intracardiac electrograms (IEGMs) stored in the implantable defibrillators (ICDs) or cardiac resynchronization therapy (CRT-D) recipients.Methods: Data from the Home Monitoring Expert Alliance project, a pooled repository of remote monitoring transmissions were analyzed. All IEGMs stored were independently adjudicated by three cardiac electrophysiologists. Periodicity of SVA was evaluated with Generalized Estimating Equations (GEE) models, including periodic terms depending on months in a year.Results: A total of 2936 ICD/CRT-D patients (median age 70 years, 79.6% male) were followed for a median period of 25[13-44] months. Most prevalent structural heart diseases were ischemic (50.8%) and idiopathic dilated (30.6%) cardiomyopathies. Overall, 942 (32.1%) patients experienced a total of 4824 SVA. At GEE analysis, we found a significant periodic component (p=0.048) when considering both shocked and non-shocked episodes. SVA less frequently occurred in Junes and Julies (3.7 x 1000 patient-month). No evidence of significant periodicity was collected in the subgroup of ischemic patients.Conclusions: In thisRM-based cohort of ICD/ CRT-T patients, we observed an annual periodicity of SVA occurrence, with a lower incidence in summer months. (c) 2018 Elsevier B.V. All rights reserved