1,557 research outputs found

    Differential Requirements for COPI Coats in Formation of Replication Complexes among Three Genera of Picornaviridae

    Get PDF
    Picornavirus RNA replication requires the formation of replication complexes (RCs) consisting of virus-induced vesicles associated with viral nonstructural proteins and RNA. Brefeldin A (BFA) has been shown to strongly inhibit RNA replication of poliovirus but not of encephalomyocarditis virus (EMCV). Here, we demonstrate that the replication of parechovirus 1 (ParV1) is partly resistant to BFA, whereas echovirus 11 (EV11) replication is strongly inhibited. Since BFA inhibits COPI-dependent steps in endoplasmic reticulum (ER)-Golgi transport, we tested a hypothesis that different picornaviruses may have differential requirements for COPI in the formation of their RCs. Using immunofluorescence and cryo-immunoelectron microscopy we examined the association of a COPI component, ß-COP, with the RCs of EMCV, ParV1, and EV11. EMCV RCs did not contain ß-COP. In contrast, ß-COP appeared to be specifically distributed to the RCs of EV11. In ParV1-infected cells ß-COP was largely dispersed throughout the cytoplasm, with some being present in the RCs. These results suggest that there are differences in the involvement of COPI in the formation of the RCs of various picornaviruses, corresponding to their differential sensitivity to BFA. EMCV RCs are likely to be formed immediately after vesicle budding from the ER, prior to COPI association with membranes. ParV1 RCs are formed from COPI-containing membranes but COPI is unlikely to be directly involved in their formation, whereas formation of EV11 RCs appears to be dependent on COPI association with membranes

    Association of homocysteine and smoking with cerebral microemboli in patients with mechanical heart valves: A transcranial Doppler study

    Get PDF
    Objectives Microembolic signals (MES) on transcranial Doppler (TCD) predict stroke and cognitive decline. Plasma levels of total homocysteine (tHcy), a prothrombotic factor, are higher in patients with microemboli in carotid stenosis and in patients with paradoxical embolism. In this study we assessed the association between the level of tHcy and the number of MES in patients with mechanical heart valves (MHVs). Methods TCD monitoring was performed to detect MES before and after breathing 100% oxygen and repeated every 2-4 weeks up to six times. Results Twenty-five patients with MHVs (mean age: 63.60±10.15 years) participated in this study; 15 were men (66.47±7.25 years) and 10 were women (59.30±12.60 years). In total, there were 126 study visits. In multiple regression, higher tHcy was associated with more MES in both preoxygenation (OR 1.34 (95% CI 1.07 to 1.68, P=0.009)) and postoxygenation (OR 1.40 (95% CI 1.07 to 1.83, P=0.01)) phases. Current smoking and the length of time between the operation and monitoring also correlated with a higher number of MES before and after breathing oxygen, particularly in women. Conclusions Higher tHcy and smoking were associated with a higher MES count in both preoxygenation and postoxygenation phases. Because smoking can be stopped and hyperhomocysteinaemia is treatable, these are clinically important findings

    When innovation outpaces regulations:The legal challenges for direct-to-patient supply of investigational medicinal products

    Get PDF
    AIMS: We profile the lack of specific regulation for direct‐to‐patient postal supply (DTP) of clinical trial medications (investigational medicinal products, IMPs) calling for increased efficiency of patient‐centred multi‐country remote clinical trials. METHODS: Questionnaires emailed to 28 European Economic Area (EEA) Medical Product Licensing Authorities (MPLAs) and Swissmedic MPLA were analysed in 2019/2020. The questionnaire asked whether DTP of IMPs was legal, followed by comparative legal analysis profiling relevant national civil and criminal liability provisions in 30 European jurisdictions (including The Netherlands), finally summarising accessible COVID‐19‐related guidance in searches of 30 official MPLA websites in January 2021. RESULTS: Twenty MPLAs responded. Twelve consented to response publication in 2021. DTP was not widely authorised, though different phrases were used to explain this. Our legal review of national laws in 29 EEA jurisdictions and Switzerland did not identify any specific sanctions for DTP of IMPs; however, we identified potential national civil and criminal liability provisions. Switzerland provides legal clarity where DTP of IMPs is conditionally legal. MPLA webpage searches for COVID‐19 guidance noted conditional acceptance by 19 MPLAs. CONCLUSIONS: Specific national legislation authorising DTP of IMPs, defining IMP categories, and conditions permitting the postage and delivery by courier in an EEA‐wide clinical trial, would support innovative patient‐centred research for multi‐country remote clinical trials. Despite it appearing more acceptable to do this between EU Member States, provided each EU MPLA and ethics board authorises it, temporary Covid‐19 restrictions in national Good Clinical Practice (GCP) guidance discourages innovative research into the safety and effectiveness of clinical trial medications

    Home blood pressure monitors owned by participants in a large decentralised clinical trial in hypertension:the Treatment In Morning versus Evening (TIME) study

    Get PDF
    Various home blood pressure monitors (HBPMs) are available to the public for purchase but only some are validated against standardised protocols. This study aimed to assess whether HBPMs owned by participants taking part in a clinical trial were validated models. The TIME study is a decentralised randomised trial investigating the effect of antihypertensive medication dosing time on cardiovascular outcomes in adults with hypertension. No HBPMs were provided to participants in this trial but patients were asked to report if they already owned one. We identified the model of HBPM reported by participants, then cross-referenced this against lists of validated HBPMs produced by dabl Educational Trust and the British and Irish Hypertension Society (BIHS). Of 21,104 participants, 10,464 (49.6%) reported their model of HBPM. 7464 (71.3%) of these participants owned a monitor that could be identified from the participants’ entry. Of these, 6066 (81.3%) participants owned a monitor listed as validated by either dabl (n = 5903) or BIHS (n = 5491). Some were listed as validated by both. 1398 (18.7%) participants owned an identifiable HBPM that lacked clear evidence of validation. 6963 (93.3%) participants owned an upper arm HBPM and 501 (6.7%) owned a wrist HBPM. Validated HBPMs had a higher median online retail price of £45.00 compared to £20.00 for HBPMs lacking clear evidence of validation. A significant number of participants own HBPMs lacking evidence of validation

    Fast and flexible selection with a single switch

    Get PDF
    Selection methods that require only a single-switch input, such as a button click or blink, are potentially useful for individuals with motor impairments, mobile technology users, and individuals wishing to transmit information securely. We present a single-switch selection method, "Nomon," that is general and efficient. Existing single-switch selection methods require selectable options to be arranged in ways that limit potential applications. By contrast, traditional operating systems, web browsers, and free-form applications (such as drawing) place options at arbitrary points on the screen. Nomon, however, has the flexibility to select any point on a screen. Nomon adapts automatically to an individual's clicking ability; it allows a person who clicks precisely to make a selection quickly and allows a person who clicks imprecisely more time to make a selection without error. Nomon reaps gains in information rate by allowing the specification of beliefs (priors) about option selection probabilities and by avoiding tree-based selection schemes in favor of direct (posterior) inference. We have developed both a Nomon-based writing application and a drawing application. To evaluate Nomon's performance, we compared the writing application with a popular existing method for single-switch writing (row-column scanning). Novice users wrote 35% faster with the Nomon interface than with the scanning interface. An experienced user (author TB, with > 10 hours practice) wrote at speeds of 9.3 words per minute with Nomon, using 1.2 clicks per character and making no errors in the final text.Comment: 14 pages, 5 figures, 1 table, presented at NIPS 2009 Mini-symposi

    Reversible hysteresis inversion in MoS<sub>2</sub> field effect transistors

    Get PDF
    MoS2 devices: variable temperature measurements unveil reversible hysteresis mechanisms Defects and traps in MoS2 van der Pauw devices give rise to a hysteresis inversion mechanism which is reversible with temperature. A team led by Saurabh Lodha at the Indian Institute of Technology Bombay performed variable temperature hysteresis measurements on four- and two-terminal MoS2 devices, both suspended and supported on a SiO2 substrate. The onset of a clockwise hysteresis at room temperature was attributed to intrinsic MoS2 defects, whereas an additional mechanism resulting in an anticlockwise hysteresis was observed at higher temperature, and attributed to extrinsic charge trapping and de-trapping between the oxide and the silicon gate. By leveraging the temperature dependence of the hysteresis in MoS2, the authors developed a non-volatile memory and a temperature sensor
    • 

    corecore