3 research outputs found

    Dose mapping of products with different density irradiated in 60co irradiation facility of the Vinca institute, Serbia

    Get PDF
    The distribution of the absorbed dose within the irradiated product is a complex function of the product density and homogeneity, the position and shape of the radiation source, as well as the design of the irradiator. In this paper, detailed mapping of absorbed radiation doses in products of different density: gauze, plastic, and soil, is performed. Positions of minimum and maximum absorbed radiation dose were determined, and the homogeneity of irradiation of products was calculated using the ethanol-monochlorobenzene oscillotitrator dosimetry system

    Use of low-energy electron-beam in the treatment of special food products with a high protein content

    Get PDF
    Special high-protein foods suitable for diabetics must be treated to ensure the complete absence of microorganisms and bacteria. It is also important to achieve that this treatment does not change the nutritional value of the product. Among the new decontamination technologies, low-energy electron-beam treatment has proven to be an effective technique for inactivating bacteria with minimal impact on food quality. The paper aims to analyze the influence of low-energy electron-beam irradiation on the microbiological properties and nutritional value of high-protein foods

    Accuracy in determining absorbed irradiation dose at different temperature measurements using ethanol chlorobenzene - oscillotitrator system

    No full text
    Ethanol-chlorobenzene/oscillotitrator dosimetry system is widely used in controlling the irradiation process in gamma facilities. The ethanol-chlorobenzene dosimetry system provides a reliable means of measuring absorbed dose. It is based on a process of radiolytic formation of hydrochloric acid in aqueous ethanolic solutions of chlorobenzene by ionizing radiation. The irradiation temperature dependence of dosimeter response is a complex function of dose and temperature for each concentration of chlorobenzene. At different temperature the mobility of conducting species from hydrochloric acid is changed leading to different oscillotitrator deflections during high-frequency conductometric readout. In this paper, we examined the influence of temperature on the calculation of the radiation dose. We showed that the temperature significantly influenced the measurement results, and that the calibration curve has to be formed at the irradiation temperature in order to obtain precise values of the absorbed dose
    corecore