1,500 research outputs found

    S14: Factors Affecting Dental Students’ Comfort with Online Synchronous Learning

    Get PDF
    Background: The COVID-19 pandemic has caused many universities to expand the use of videoconferencing technology to continue academic coursework. This study examines dental students’ experience with videoconferencing technology, comfort levels, and perceptions of using videoconferencing technology. Methods: 54 out of 100 second-year dental students enrolled in a course on local anesthesia, 54 completed a survey following an online synchronous lecture given in September 2020. Survey questions asked about prior experience with videoconferencing, comfort levels, and reasons for not turning on their video (showing their face). Results: Overall, 48.2% had little or no prior experience with videoconferencing prior to March 2020. The Regression analyses showed there were significant positive associations between ratings of experience and comfort with answering questions and interacting in breakouts (r=.55, p=.04 and r=.54, p=0.03, respectively). Students were significantly more comfortable interacting with each other more during in-person than on-line breakout sessions than on-line breakout sessions (p=0.003). Although not significant, students were more comfortable in-person than on-line for all other classroom parameters. The main reasons students did not turn on their for not using the video feature were that they did not want to dress up (48.1%), others were not using their video (46.3%), and feeling that they did not look good (35.5%). Conclusion: Students who had prior experience with videoconferencing technology were more comfortable actively participating in online synchronous lectures. Students reported feeling more comfortable interacting during in-person breakout groups than in online breakout groups. The most significant reasons for students not using the video feature (showing their face) relate to inconvenience, peers not using the video feature, and self-consciousness

    Transplanckian axions !?

    Full text link
    We discuss quantum gravitational effects in Einstein theory coupled to periodic axion scalars to analyze the viability of several proposals to achieve superplanckian axion periods (aka decay constants) and their possible application to large field inflation models. The effects we study correspond to the nucleation of euclidean gravitational instantons charged under the axion, and our results are essentially compatible with (but independent of) the Weak Gravity Conjecture, as follows: Single axion theories with superplanckian periods contain gravitational instantons inducing sizable higher harmonics in the axion potential, which spoil superplanckian inflaton field range. A similar result holds for multi-axion models with lattice alignment (like the Kim-Nilles-Peloso model). Finally, theories with NN axions can still achieve a moderately superplanckian periodicity (by a N\sqrt{N} factor) with no higher harmonics in the axion potential. The Weak Gravity Conjecture fails to hold in this case due to the absence of some instantons, which are forbidden by a discrete ZN\mathbf{Z}_N gauge symmetry. Finally we discuss the realization of these instantons as euclidean D-branes in string compactifications.Comment: 46 pages, 6 figures. Added references, clarifications, and missing factor of 1/2 to instanton action. Conclusions unchange

    Understanding and meeting the needs of those using growth hormone injection devices

    Get PDF
    BACKGROUND: Recombinant human growth hormone (r-hGH) is used to treat: growth hormone deficiency in children and adults; children born small for gestational age; Turner's syndrome; and chronic renal failure. r-hGH is administered by daily subcutaneous injection and may be given using a number of different administration devices. The aim of this survey was, firstly, to identify which attributes of an r-hGH administration device are considered most important to physicians, teenage patients, parents of young children requiring GH and nurses who have experience of r-hGH administration, and, secondly, to determine how they rate existing devices in each of these key attributes. METHODS: The opinions of 67 individuals with experience in r-hGH administration were captured in discussion sessions. Parents, physicians and nurses were asked to rate 19 device attributes by completing a questionnaire, and to rank four different r-hGH administration devices (including a conceptual electronic device) in order of preference. RESULTS: Reliability, ease of use, lack of pain during injection, safety in use, storage, and number of steps in preparation before use, during use and after were considered to be the five most desirable attributes of an r-hGH administration device. An electronic device was preferred to an automatic, multi-dose injection device, a needle-free injection device or a manual, ready-to-use, disposable injection device. CONCLUSION: In the opinion of physicians, nurses and parents using r-hGH injection devices, an ideal device must combine reliability with simplicity, while delivering treatment with minimal pain. An electronic device, which combines many of the most useful features of existing devices with novel functions, was the preferred option for r-hGH administration

    Percutaneous injuries among dental professionals in Washington State

    Get PDF
    BACKGROUND: Percutaneous exposure incidents facilitate transmission of bloodborne pathogens such as human immunodeficiency virus (HIV), hepatitis C virus (HCV) and hepatitis B virus (HBV). This study was conducted to identify the circumstances and equipment related to percutaneous injuries among dental professionals. METHODS: We used workers' compensation claims submitted to the Department of Labor and Industries State Fund during a 7-year period (1995 through 2001) in Washington State for this study. We used the statement submitted by the injured worker on the workers' compensation claim form to determine the circumstances surrounding the injury including the type of activity and device involved. RESULTS: Of a total of 4,695 accepted State Fund percutaneous injury claims by health care workers (HCWs), 924 (20%) were submitted by dental professionals. Out of 924 percutaneous injuries reported by dental professionals 894 (97%) were among dental health care workers in non-hospital settings, including dentists (66, 7%), dental hygienists (61, 18%) and dental assistants (667, 75%). The majority of those reporting were females (638, 71%). Most (781, 87%) of the injuries involved syringes, dental instruments (77, 9%), and suture needles (23%). A large proportion (90%) of injuries occurred in offices and clinics of dentists, while remainder occurred in offices of clinics and of doctors of medicine (9%), and a few in specialty outpatient facilities (1%). Of the 894 dental health care workers with percutaneous injuries, there was evidence of HBV in 6 persons, HCV in 30 persons, HIV in 3 persons and both HBV and HVC (n = 2) exposure. CONCLUSION: Out of hospital percutaneous injuries are a substantial risk to dental health professionals in Washington State. Improved work practices and safer devices are needed to address this risk

    Gene deletion of P-Selectin and ICAM-1 does not inhibit neutrophil infiltration into peritoneal cavity following cecal ligation-puncture

    Get PDF
    BACKGROUND: Neutrophil infiltration is one of the critical cellular components of an inflammatory response during peritonitis. The adhesion molecules, P-selectin and intercellular adhesion molecule (ICAM)-1, mediate neutrophil-endothelial cell interactions and the subsequent neutrophil transendothelial migration during the inflammatory response. Despite very strong preclinical data, recent clinical trials failed to show a protective effect of anti-adhesion therapy, suggesting that the length of injury might be a critical factor in neutrophil infiltration. Therefore, the objective of this study was to determine the role of P-selectin and ICAM-1 in neutrophil infiltration into the peritoneal cavity during early and late phases of peritonitis. METHODS: Peritonitis was induced in both male wild-type and P-selectin/ICAM-1 double deficient (P/I null) mice by cecal ligation-puncture (CLP). Peripheral blood and peritoneal lavage were collected at 6 and 24 hours after CLP. The total leukocyte and neutrophil contents were determined, and neutrophils were identified with the aid of in situ immunohistochemical staining. Comparisons between groups were made by applying ANOVA and student t-test analysis. RESULTS: CLP induced a severe inflammatory response associated with a significant leukopenia in both wild-type and P/I null mice. Additionally, CLP caused a significant neutrophil infiltration into the peritoneal cavity that was detected in both groups of mice. However, neutrophil infiltration in the P/I null mice at 6 hours of CLP was significantly lower than the corresponding wild-type mice, which reached a similar magnitude at 24 hours of CLP. In contrast, in peritonitis induced by intraperitoneal inoculation of 2% glycogen, no significant difference in neutrophil infiltration was observed between the P/I null and wild-type mice at 6 hours of peritonitis. CONCLUSIONS: The data suggest that alternative adhesion pathway(s) independent of P-selectin and ICAM-1 can participate in neutrophil migration during peritonitis and that the mode of stimuli and duration of the injury modulate the neutrophil infiltration

    Declining recurrence among ductal carcinoma in situ patients treated with breast-conserving surgery in the community setting

    Get PDF
    Introduction: Randomized trials indicate that adjuvant radiotherapy plus tamoxifen decrease the five-year risk of recurrence among ductal carcinoma in situ patients treated with breast-conserving surgery from about 20% to 8%. The aims of this study were to examine the use and impact of these therapies on risk of recurrence among ductal carcinoma in situ patients diagnosed and treated in the community setting. Methods: We identified 2,995 patients diagnosed with ductal carcinoma in situ between 1990 and 2001 and treated with breast-conserving surgery at three large health plans. Medical charts were reviewed to confirm diagnosis and treatment and to obtain information on subsequent breast cancers. On a subset of patients, slides from the index ductal carcinoma in situ were reviewed for histopathologic features. Cumulative incidence curves were generated and Cox regression was used to examine changes in five-year risk of recurrence across diagnosis years, with and without adjusting for trends in use of adjuvant therapies. Results: Use of radiotherapy increased from 25.8% in 1990-1991 to 61.3% in 2000-2001; tamoxifen increased from 2.3% to 34.4%. A total of 245 patients had a local recurrence within five years of their index ductal carcinoma in situ. The five-year risk of any local recurrence decreased from 14.3% (95% confidence interval 9.8 to 18.7) for patients diagnosed in 1990-1991 to 7.7% (95% confidence interval 5.5 to 9.9) for patients diagnosed in 1998-1999; invasive recurrence decreased from 7.0% (95% confidence interval 3.8 to 10.3) to 3.1% (95% confidence interval 1.7 to 4.6). In Cox models, the association between diagnosis year and risk of recurrence was modestly attenuated after accounting for use of adjuvant therapy. Between 1990-1991 and 2000-2001, the proportion of patients with tumors with high nuclear grade decreased from 46% to 32% (P = 0.03) and those with involved surgical margins dropped from 15% to 0% (P = 0.03). Conclusions: The marked increase in the 1990s in the use of adjuvant therapy for ductal carcinoma in situ patients treated with breast-conserving surgery in the community setting only partially explains the 50% decline in risk of recurrence. Changes in pathology factors have likely also contributed to this decline

    Optimization of atmospheric plasma treatment of LDPE films: Influence on adhesive properties and ageing behavior

    Full text link
    One of the major disadvantages of low density polyethylene (LDPE) films is their poor adhesive properties. Therefore, LDPE films have been treated with atmospheric pressure air plasma in order to improve their surface properties. So as to simulate the possible conditions in an industrial process, the samples have been treated with two different sample distances (6 and 10 mm), and treatment rates between 100 and 1000 mm s-1. The different sample distances are the distance of the sample from the plasma source. The variation of the surface properties and adhesion characteristics of the films were investigated for different aging times after plasma exposure (up to 21 days) using contact angle measurement, atomic force microscopy, weight loss measurements and shear test. Results show that the treatment increases the polar component () and these changes improve adhesive properties of the material. After the twenty-first day, the ageing process causes a decrease of wettability and adhesive properties of the LDPE films (up to 60%).Fombuena Borrás, V.; García Sanoguera, D.; Sánchez Nacher, L.; Balart Gimeno, RA.; Boronat Vitoria, T. (2014). Optimization of atmospheric plasma treatment of LDPE films: Influence on adhesive properties and ageing behavior. Journal of Adhesion Science and Technology. 28(1):97-113. doi:10.1080/01694243.2013.847045S97113281Achilias, D. S., Roupakias, C., Megalokonomos, P., Lappas, A. A., & Antonakou, Ε. V. (2007). Chemical recycling of plastic wastes made from polyethylene (LDPE and HDPE) and polypropylene (PP). Journal of Hazardous Materials, 149(3), 536-542. doi:10.1016/j.jhazmat.2007.06.076Friedman, M., & Walsh, G. (2002). High performance films: Review of new materials and trends. Polymer Engineering & Science, 42(8), 1756-1788. doi:10.1002/pen.11069Wiles, D. M., & Scott, G. (2006). Polyolefins with controlled environmental degradability. Polymer Degradation and Stability, 91(7), 1581-1592. doi:10.1016/j.polymdegradstab.2005.09.010Gao, J., Lei, J., Li, Q., & Ye, S. (2004). Functionalized low-density polyethylene via a novel photografting method and its adhesion properties. Journal of Adhesion Science and Technology, 18(2), 195-203. doi:10.1163/156856104772759403Shenton, M. J., Lovell-Hoare, M. C., & Stevens, G. C. (2001). Adhesion enhancement of polymer surfaces by atmospheric plasma treatment. Journal of Physics D: Applied Physics, 34(18), 2754-2760. doi:10.1088/0022-3727/34/18/307Belgacem, M. N., Salon-Brochier, M. C., Krouit, M., & Bras, J. (2011). Recent Advances in Surface Chemical Modification of Cellulose Fibres. Journal of Adhesion Science and Technology, 25(6-7), 661-684. doi:10.1163/016942410x525867Friedrich, J., Unger, W., & Lippitz, A. (1995). Plasma modification of polymer surfaces. Macromolecular Symposia, 100(1), 111-115. doi:10.1002/masy.19951000118Ladizesky, N. H., & Ward, I. M. (1989). The adhesion behaviour of high modulus polyethylene fibres following plasma and chemical treatment. Journal of Materials Science, 24(10), 3763-3773. doi:10.1007/bf02385768Nardin, M., & Ward, I. M. (1987). Influence of surface treatment on adhesion of polyethylene fibres. Materials Science and Technology, 3(10), 814-826. doi:10.1179/mst.1987.3.10.814Villagra Di Carlo, B., Gottifredi, J. C., & Habert, A. C. (2010). Synthesis and characterization of composite membrane by deposition of acrylic acid plasma polymer onto pre-treated polyethersulfone support. Journal of Materials Science, 46(6), 1850-1856. doi:10.1007/s10853-010-5012-4Matsunaga, M., & Whitney, P. J. (2000). Surface changes brought about by corona discharge treatment of polyethylene film and the effect on subsequent microbial colonisation. Polymer Degradation and Stability, 70(3), 325-332. doi:10.1016/s0141-3910(00)00105-1Novák, I., Pollák, V., & Chodák, I. (2006). Study of Surface Properties of Polyolefins Modified by Corona Discharge Plasma. Plasma Processes and Polymers, 3(4-5), 355-364. doi:10.1002/ppap.200500163Arpagaus, C., Rossi, A., & Rudolf von Rohr, P. (2005). Short-time plasma surface modification of HDPE powder in a Plasma Downer Reactor – process, wettability improvement and ageing effects. Applied Surface Science, 252(5), 1581-1595. doi:10.1016/j.apsusc.2005.02.099Morra, M., Occhiello, E., Marola, R., Garbassi, F., Humphrey, P., & Johnson, D. (1990). On the aging of oxygen plasma-treated polydimethylsiloxane surfaces. Journal of Colloid and Interface Science, 137(1), 11-24. doi:10.1016/0021-9797(90)90038-pKim, K. S., Ryu, C. M., Park, C. S., Sur, G. S., & Park, C. E. (2003). Investigation of crystallinity effects on the surface of oxygen plasma treated low density polyethylene using X-ray photoelectron spectroscopy. Polymer, 44(20), 6287-6295. doi:10.1016/s0032-3861(03)00674-8Kim, S. H., Ha, H. J., Ko, Y. K., Yoon, S. J., Rhee, J. M., Kim, M. S., 
 Khang, G. (2007). Correlation of proliferation, morphology and biological responses of fibroblasts on LDPE with different surface wettability. Journal of Biomaterials Science, Polymer Edition, 18(5), 609-622. doi:10.1163/156856207780852514Borcia, G., Anderson, C. A., & Brown, N. M. D. (2004). The surface oxidation of selected polymers using an atmospheric pressure air dielectric barrier discharge. Part I. Applied Surface Science, 221(1-4), 203-214. doi:10.1016/s0169-4332(03)00879-1Pascual, M., Calvo, O., Sanchez-Nácher, L., Bonet, M. A., Garcia-Sanoguera, D., & Balart, R. (2009). Optimization of adhesive joints of low density polyethylene (LDPE) composite laminates with polyolefin foam using corona discharge plasma. Journal of Applied Polymer Science, 114(5), 2971-2977. doi:10.1002/app.30906Encinas, N., Díaz-Benito, B., Abenojar, J., & Martínez, M. A. (2010). Extreme durability of wettability changes on polyolefin surfaces by atmospheric pressure plasma torch. Surface and Coatings Technology, 205(2), 396-402. doi:10.1016/j.surfcoat.2010.06.069Takke, V., Behary, N., Perwuelz, A., & Campagne, C. (2009). Studies on the atmospheric air-plasma treatment of PET (polyethylene terephtalate) woven fabrics: Effect of process parameters and of aging. Journal of Applied Polymer Science, 114(1), 348-357. doi:10.1002/app.30618Awaja, F., Gilbert, M., Kelly, G., Fox, B., & Pigram, P. J. (2009). Adhesion of polymers. Progress in Polymer Science, 34(9), 948-968. doi:10.1016/j.progpolymsci.2009.04.007Garcia, D., Sanchez, L., Fenollar, O., Lopez, R., & Balart, R. (2008). Modification of polypropylene surface by CH4–O2 low-pressure plasma to improve wettability. Journal of Materials Science, 43(10), 3466-3473. doi:10.1007/s10853-007-2322-2Guimond, S., & Wertheimer, M. R. (2004). Surface degradation and hydrophobic recovery of polyolefins treated by air corona and nitrogen atmospheric pressure glow discharge. Journal of Applied Polymer Science, 94(3), 1291-1303. doi:10.1002/app.21134Pascual, M., Balart, R., Sánchez, L., Fenollar, O., & Calvo, O. (2008). Study of the aging process of corona discharge plasma effects on low density polyethylene film surface. Journal of Materials Science, 43(14), 4901-4909. doi:10.1007/s10853-008-2712-0Sanchis, R., Fenollar, O., García, D., Sánchez, L., & Balart, R. (2008). Improved adhesion of LDPE films to polyolefin foams for automotive industry using low-pressure plasma. International Journal of Adhesion and Adhesives, 28(8), 445-451. doi:10.1016/j.ijadhadh.2008.04.002Fresnais, J., Chapel, J. P., Benyahia, L., & Poncin-Epaillard, F. (2009). Plasma-Treated Superhydrophobic Polyethylene Surfaces: Fabrication, Wetting and Dewetting Properties. Journal of Adhesion Science and Technology, 23(3), 447-467. doi:10.1163/156856108x370127Abenojar, J., Colera, I., Martínez, M. A., & Velasco, F. (2010). Study by XPS of an Atmospheric Plasma-Torch Treated Glass: Influence on Adhesion. Journal of Adhesion Science and Technology, 24(11-12), 1841-1854. doi:10.1163/016942410x507614Lommatzsch, U., Pasedag, D., Baalmann, A., Ellinghorst, G., & Wagner, H.-E. (2007). Atmospheric Pressure Plasma Jet Treatment of Polyethylene Surfaces for Adhesion Improvement. Plasma Processes and Polymers, 4(S1), S1041-S1045. doi:10.1002/ppap.200732402Balu, B., Berry, A. D., Patel, K. T., Breedveld, V., & Hess, D. W. (2011). Directional Mobility and Adhesion of Water Drops on Patterned Superhydrophobic Surfaces. Journal of Adhesion Science and Technology, 25(6-7), 627-642. doi:10.1163/016942410x525849Bhattacharya, S., Singh, R. K., Mandal, S., Ghosh, A., Bok, S., Korampally, V., 
 Gangopadhyay, S. (2010). Plasma Modification of Polymer Surfaces and Their Utility in Building Biomedical Microdevices. Journal of Adhesion Science and Technology, 24(15-16), 2707-2739. doi:10.1163/016942410x511105Das, S., Neogi, S., Chainy, G. B. N., & Guha, S. K. (2011). A Novel Two-Step Procedure for Plasma Surface Modification of Low-Density Polyethylene for Improved Drug Adhesion in Intra Uterine Devices (IUDs). Journal of Adhesion Science and Technology, 25(1-3), 151-167. doi:10.1163/016942410x503285Schulz, U., Munzert, P., & Kaiser, N. (2010). Plasma Surface Modification of PMMA for Optical Applications. Journal of Adhesion Science and Technology, 24(7), 1283-1289. doi:10.1163/016942409x12561252292026Silverstein, M. S., Breuer, O., & Dodiuk, H. (1994). Surface modification of UHMWPE fibers. Journal of Applied Polymer Science, 52(12), 1785-1795. doi:10.1002/app.1994.070521213Inagaki, N., Narushim, K., Tuchida, N., & Miyazaki, K. (2004). Surface characterization of plasma-modified poly(ethylene terephthalate) film surfaces. Journal of Polymer Science Part B: Polymer Physics, 42(20), 3727-3740. doi:10.1002/polb.20234Nakamatsu, J., Delgado-Aparicio, L. F., Da Silva, R., & Soberon, F. (1999). Ageing of plasma-treated poly(tetrafluoroethylene) surfaces. Journal of Adhesion Science and Technology, 13(7), 753-761. doi:10.1163/156856199x00983Yun, Y. I., Kim, K. S., Uhm, S.-J., Khatua, B. B., Cho, K., Kim, J. K., & Park, C. E. (2004). Aging behavior of oxygen plasma-treated polypropylene with different crystallinities. Journal of Adhesion Science and Technology, 18(11), 1279-1291. doi:10.1163/1568561041588200Morent, R., De Geyter, N., Leys, C., Gengembre, L., & Payen, E. (2007). Study of the ageing behaviour of polymer films treated with a dielectric barrier discharge in air, helium and argon at medium pressure. Surface and Coatings Technology, 201(18), 7847-7854. doi:10.1016/j.surfcoat.2007.03.018Zhao, B., & Kwon, H. J. (2011). Adhesion of Polymers in Paper Products from the Macroscopic to Molecular Level — An Overview. Journal of Adhesion Science and Technology, 25(6-7), 557-579. doi:10.1163/016942410x52582

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≄20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≀pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≀{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  Όb-1 of data as a function of transverse momentum (pT) and the transverse energy (ÎŁETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∌0) correlation that grows rapidly with increasing ÎŁETPb. A long-range “away-side” (Δϕ∌π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ÎŁETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ÎŁETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁥2Δϕ modulation for all ÎŁETPb ranges and particle pT
    • 

    corecore