116 research outputs found

    Light-intensity physical activity and cardiometabolic biomarkers in US adolescents

    Get PDF
    BackgroundThe minimal physical activity intensity that would confer health benefits among adolescents is unknown. The purpose of this study was to examine the associations of accelerometer-derived light-intensity (split into low and high) physical activity, and moderate- to vigorous-intensity physical activity with cardiometabolic biomarkers in a large population-based sample.MethodsThe study is based on 1,731 adolescents, aged 12&ndash;19 years from the 2003/04 and 2005/06 National Health and Nutrition Examination Survey. Low light-intensity activity (100&ndash;799 counts/min), high light-intensity activity (800 counts/min to &lt;4 METs) and moderate- to vigorous-intensity activity (&ge;4 METs, Freedson age-specific equation) were accelerometer-derived. Cardiometabolic biomarkers, including waist circumference, systolic blood pressure, diastolic blood pressure, HDL-cholesterol, and C-reactive protein were measured. Triglycerides, LDL- cholesterol, insulin, glucose, and homeostatic model assessments of &beta;-cell function (HOMA-%B) and insulin sensitivity (HOMA-%S) were also measured in a fasting sub-sample (n=807).ResultsAdjusted for confounders, each additional hour/day of low light-intensity activity was associated with 0.59 (95% CI: 1.18&ndash;0.01) mmHG lower diastolic blood pressure. Each additional hour/day of high light-intensity activity was associated with 1.67 (2.94&ndash;0.39) mmHG lower diastolic blood pressure and 0.04 (0.001&ndash;0.07) mmol/L higher HDL-cholesterol. Each additional hour/day of moderate- to vigorous-intensity activity was associated with 3.54 (5.73&ndash;1.35) mmHG lower systolic blood pressure, 5.49 (1.11&ndash;9.77)% lower waist circumference, 25.87 (6.08&ndash;49.34)% lower insulin, and 16.18 (4.92&ndash;28.53)% higher HOMA-%S.ConclusionsTime spent in low light-intensity physical activity and high light-intensity physical activity had some favorable associations with biomarkers. Consistent with current physical activity recommendations for adolescents, moderate- to vigorous-intensity activity had favorable associations with many cardiometabolic biomarkers. While increasing MVPA should still be a public health priority, further studies are needed to identify dose-response relationships for light-intensity activity thresholds to inform future recommendations and interventions for adolescents.</div

    An overview of the utilisation of microalgae biomass derived from nutrient recycling of wet market wastewater and slaughterhouse wastewater

    Get PDF
    Microalgae have high nutritional values for aquatic organisms compared to fish meal, because microalgae cells are rich in proteins, lipids, and carbohydrates. However, the high cost for the commercial production of microalgae biomass using fresh water or artificial media limits its use as fish feed. Few studies have investigated the potential of wet market wastewater and slaughterhouse wastewater for the production of microalgae biomass. Hence, this study aims to highlight the potential of these types of wastewater as an alternative superior medium for microalgae biomass as they contain high levels of nutrients required for microalgae growth. This paper focuses on the benefits of microalgae biomass produced during the phycore-mediation of wet market wastewater and slaughterhouse wastewater as fish feed. The extraction techniques for lipids and proteins as well as the studies conducted on the use of microalgae biomass as fish feed were reviewed. The results showed that microalgae biomass can be used as fish feed due to feed utilisation efficiency, physiological activity, increased resistance for several diseases, improved stress response, and improved protein retention

    Biomethanation potential of biological and other wastes

    Get PDF
    Anaerobic technology has been traditionally applied for the treatment of carbon rich wastewater and organic residues. Anaerobic processes can be fully integrated in the biobased economy concept for resource recovery. After a brief introduction about applications of anaerobic processes to industrial wastewater treatment, agriculture feedstock and organic fraction of municipal solid waste, the position of anaerobic processes in biorefinery concepts is presented. Integration of anaerobic digestion with these processes can help in the maximisation of the economic value of the biomass used, while reducing the waste streams produced and mitigating greenhouse gases emissions. Besides the integration of biogas in the existing full-scale bioethanol and biodiesel production processes, the potential applications of biogas in the second generation lignocellulosic, algae and syngas-based biorefinery platforms are discussed.(undefined

    Nothing Lasts Forever: Environmental Discourses on the Collapse of Past Societies

    Get PDF
    The study of the collapse of past societies raises many questions for the theory and practice of archaeology. Interest in collapse extends as well into the natural sciences and environmental and sustainability policy. Despite a range of approaches to collapse, the predominant paradigm is environmental collapse, which I argue obscures recognition of the dynamic role of social processes that lie at the heart of human communities. These environmental discourses, together with confusion over terminology and the concepts of collapse, have created widespread aporia about collapse and resulted in the creation of mixed messages about complex historical and social processes

    The lancet weight determines wheal diameter in response to skin prick testing with histamine

    Get PDF
    BACKGROUND:Skin prick test (SPT) is a common test for diagnosing immunoglobulin E-mediated allergies. In clinical routine, technicalities, human errors or patient-related biases, occasionally results in suboptimal diagnosis of sensitization. OBJECTIVE:Although not previously assessed qualitatively, lancet weight is hypothesized to be important when performing SPT to minimize the frequency of false positives, false negatives, and unwanted discomfort. METHODS:Accurate weight-controlled SPT was performed on the volar forearms and backs of 20 healthy subjects. Four predetermined lancet weights were applied (25 g, 85 g, 135 g and 265 g) using two positive control histamine solutions (1 mg/mL and 10 mg/mL) and one negative control (saline). A total of 400 SPTs were conducted. The outcome parameters were: wheal size, neurogenic inflammation (measured by superficial blood perfusion), frequency of bleeding, and the lancet provoked pain response. RESULTS:The mean wheal diameter increased significantly as higher weights were applied to the SPT lancet, e.g. from 3.2 ± 0.28 mm at 25 g to 5.4 ± 1.7 mm at 265 g (p<0.01). Similarly, the frequency of bleeding, the provoked pain, and the neurogenic inflammatory response increased significantly. At 265 g saline evoked two wheal responses (/160 pricks) below 3 mm. CONCLUSION AND CLINICAL RELEVANCE:The applied weight of the lancet during the SPT-procedure is an important factor. Higher lancet weights precipitate significantly larger wheal reactions with potential diagnostic implications. This warrants additional research of the optimal lancet weight in relation to SPT-guidelines to improve the specificity and sensitivity of the procedure

    Comparison of two different physical activity monitors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Understanding the relationships between physical activity (PA) and disease has become a major area of research interest. Activity monitors, devices that quantify free-living PA for prolonged periods of time (days or weeks), are increasingly being used to estimate PA. A range of different activity monitors brands are available for investigators to use, but little is known about how they respond to different levels of PA in the field, nor if data conversion between brands is possible.</p> <p>Methods</p> <p>56 women and men were fitted with two different activity monitors, the Actigraph™ (Actigraph LLC; AGR) and the Actical™ (Mini-Mitter Co.; MM) for 15 days. Both activity monitors were fixed to an elasticized belt worn over the hip, with the anterior and posterior position of the activity monitors randomized. Differences between activity monitors and the validity of brand inter-conversion were measured by <it>t</it>-tests, Pearson correlations, Bland-Altman plots, and coefficients of variation (CV).</p> <p>Results</p> <p>The AGR detected a significantly greater amount of daily PA (216.2 ± 106.2 vs. 188.0 ± 101.1 counts/min, P < 0.0001). The average difference between activity monitors expressed as a CV were 3.1 and 15.5% for log-transformed and raw data, respectively. When a conversion equation was applied to convert datasets from one brand to another, the differences were no longer significant, with CV's of 2.2 and 11.7%, log-transformed and raw data, respectively.</p> <p>Conclusion</p> <p>Although activity monitors predict PA on the same scale (counts/min), the results between these two brands are not directly comparable. However, the data are comparable if a conversion equation is applied, with better results for log-transformed data.</p

    French Pregnancy Physical Activity Questionnaire Compared with an Accelerometer Cut Point to Classify Physical Activity among Pregnant Obese Women

    Get PDF
    Given the high risk for inactivity during pregnancy in obese women, validated questionnaires for physical activity (PA) assessment in this specific population is required before evaluating the effect of PA on perinatal outcomes. No questionnaire was validated in pregnant obese women. The Pregnancy Physical Activity Questionnaire (PPAQ) has been designed based on activities reported during pregnancy and validated in pregnant women. We translated the PPAQ to French and assessed reliability and accuracy of this French version among pregnant obese women. In this cross-sectional study, pregnant obese women were evenly recruited at the end of each trimester of pregnancy. They completed the PPAQ twice, with an interval of 7 days in-between, to recall PA of the last three months. Between PPAQ assessments, participants wore an accelerometer (Actigraph GT1M) during 7 consecutive days. Fourty-nine (49) pregnant obese women (29.8±4.2 yrs, 34.7±5.1 kg.m−2) participated to the study. The intraclass correlation coefficients (ICCs) between the two PPAQ assessments were 0.90 for total activity, 0.86 for light and for moderate intensity, and 0.81 for vigorous intensity activities. It ranged from 0.59 for “Transportation” to 0.89 for “Household and Caregiving” activities. Spearman correlation coefficients (SCCs) between the PPAQ and the Matthews’ cut point used to classify an activity of moderate and above intensity were 0.50 for total activity, 0.25 for vigorous intensity and 0.40 for moderate intensity. The correlations between the PPAQ and the accelerometer counts were 0.58 for total activity, 0.39 for vigorous intensity and 0.49 for moderate intensity. The highest SCCs were for “Occupation” and “Household and Caregiving” activities. Comparisons with other standard cutpoints were presented in files S1, S2, S3, S4, S5, S6, S7. The PPAQ is reliable and moderately accurate for the measure of PA of various intensities and types among pregnant obese women

    Development and testing of the BONES physical activity survey for young children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Weight-bearing and high intensity physical activities are particularly beneficial for stimulating bone growth in children given that bone responds favorably to mechanical load. While it is important to assess the contribution and impact of weight-bearing physical activity on health outcomes, measurement tools that quantify and provide information on these activities separately from overall physical activity are limited. This study describes the development and evaluation of a pictorial physical activity survey (PAS) that measures children's participation and knowledge of high-intensity, weight-bearing ("bone smart") physical activity.</p> <p>Methods</p> <p>To test reliability, two identical sets of the PAS were administered on the same day to 41 children (mean age 7.1 ± 0.8 years; 63% female) and compared. To test validity, accelerometry data from 40 children (mean age 7.7 ± 0.8 years; 50% female) were compared to data provided by the PAS. Agreements between categorical and ordinal items were assessed with Kappa statistics; agreements between continuous indices were assessed with Spearman's correlation tests.</p> <p>Results</p> <p>The subjects produced reliable results in all 10 physical activity participation items (κ range: 0.36-0.73, all p < 0.05), but less reliable in answering if the physical activities were "bone smart" (κ range: -0.04-0.66). Physical activity indices, including metabolic equivalent time and weight-bearing factors, were significant in test-retest analyses (Spearman's <it>r </it>range: 0.57-0.74, all p < 0.001). Minutes of very vigorous activity from the accelerometer were associated with the self-reported weight-bearing activity, moderate-high, and high activity scores from the PAS (Spearman's <it>r </it>range: 0.47-0.48, all p < 0.01). However, accelerometer counts, counts per minute, and minutes of moderate-vigorous and vigorous activity were not associated with the PAS scores.</p> <p>Conclusions</p> <p>Together, the results of these studies suggest that the PAS has acceptable test-retest reliability, but limited validity for early elementary school children. This survey demonstrates a first step towards developing a questionnaire that measures high intensity, weight-bearing activity in schoolchildren.</p

    Volume, patterns, and types of sedentary behavior and cardio-metabolic health in children and adolescents: a cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardio-metabolic risk factors are becoming more prevalent in children and adolescents. A lack of moderate-to-vigorous intensity physical activity (MVPA) is an established determinant of cardio-metabolic risk factors in children and adolescents. Less is known about the relationship between sedentary behavior and cardio-metabolic health. Therefore, the objective was to examine the independent associations between volume, patterns, and types of sedentary behavior with cardio-metabolic risk factors among children and adolescents.</p> <p>Methods</p> <p>The results are based on 2527 children and adolescents (6-19 years old) from the 2003/04 and 2005/06 National Health and Nutrition Examination Surveys (NHANES). A cardio-metabolic risk score (CRS) was calculated based on age- and sex-adjusted waist circumference, systolic blood pressure, non-high-density lipoprotein cholesterol, and C-reactive protein values. Volume and patterns of sedentary behavior and moderate-to-vigorous physical activity (MVPA) were measured objectively using accelerometers. Types of sedentary behavior were measured by questionnaire. A series of logistic regression models were used to examine associations.</p> <p>Results</p> <p>Volume and patterns of sedentary behavior were not predictors of high CRS after adjusting for MVPA and other confounders (P > 0.1). For types of sedentary behavior, high TV use, but not high computer use, was a predictor of high CRS after adjustment for MVPA and other confounders. Children and adolescents who watched ≥4 hours per day of TV were 2.53 (95% confidence interval: 1.45-4.42) times more likely to have high CRS than those who watched <1 hour per day. MVPA predicted high CRS after adjusting for all sedentary behavior measures and other confounders. After adjustment for waist circumference, MVPA also predicted high non-obesity CRS; however, the same relationship was not seen with TV use.</p> <p>Conclusion</p> <p>No association was observed between overall volume and patterns of sedentary behavior with cardio-metabolic risk factors in this large sample of children and adolescents. Conversely, high TV use and low MVPA were independently associated with cardio-metabolic risk factors. However, the association between high TV use and clustered cardio-metabolic risk factors appears to be mediated or confounded by obesity. Thus, TV and MVPA appear to be two separate behaviors that need to be targeted with different interventions and policies.</p
    corecore