53 research outputs found

    The Consequence of Self-field and Non-uniform Current Distribution on Short Sample Tests of Superconducting Cables

    Get PDF
    Electrical measurements on samples of superconducting cables are usually performed in order to determine the critical current IcI_c and the n-value, assuming that the voltage U at the transition from the superconducting to the normal state follows the power law, U\sim(I/IcI/I_c)n^n. An accurate measurement of IcI_c and n demands, first of all, good control of temperature and field, and precise measurement of current and voltage. The critical current and n-value of a cable are influenced by the self-field of the cable, an effect that has to be known in order to compare the electrical characteristics of the cable with those of the strands from which it is made. The effect of the self-field is dealt with taking into account the orientation and magnitude of the applied field and the n-value of the strands. An important source of inaccuracy is related to the distribution of the currents among the strands. Non-uniform distributions, mainly caused by non-equal resistances of the connections between the strands of the cable and the current leads, can easily result in a misinterpretation of the measured critical current and n-value by 5% and 50% respectively. In this paper this effect is explained in detail, taking also into account the influence of the current ramp-rate (during a voltage-current measurement), the sample length, the contact resistance between the strands and the placement of the voltage taps

    IP-10 Levels as an Accurate Screening Tool to Detect Acute HIV Infection in Resource-Limited Settings.

    Get PDF
    Acute HIV infection (AHI) is the period prior to seroconversion characterized by high viral replication, hyper-transmission potential and commonly, non-specific febrile illness. AHI detection requires HIV-RNA viral load (VL) determination, which has very limited access in low-income countries due to restrictive costs and implementation constraints. We sought to identify a biomarker that could enable AHI diagnosis in scarce-resource settings, and to evaluate the feasibility of its implementation. HIV-seronegative adults presenting at the Manhiça District Hospital, Mozambique, with reported-fever were tested for VL. Plasma levels of 49 inflammatory biomarkers from AHI (n = 61) and non-HIV infected outpatients (n = 65) were determined by Luminex and ELISA. IP-10 demonstrated the best predictive power for AHI detection (AUC = 0.88 [95%CI 0.80-0.96]). A cut-off value of IP-10 ≥ 161.6 pg/mL provided a sensitivity of 95.5% (95%CI 85.5-99.5) and a specificity of 76.5% (95%CI 62.5-87.2). The implementation of an IP-10 screening test could avert from 21 to 84 new infections and save from US176,609toUS176,609 to US533,467 to the health system per 1,000 tested patients. We conclude that IP-10 is an accurate biomarker to screen febrile HIV-seronegative individuals for subsequent AHI diagnosis with VL. Such an algorithm is a cost-effective strategy to prevent disease progression and a substantial number of further HIV infections

    Hostility, Physical Aggression and Trait Anger as Predictors for Suicidal Behavior in Chinese Adolescents: A School-Based Study

    Get PDF
    Purpose: This study explored the extent to which trait aggression is associated with suicidal behavior in a nationwide school-based sample of adolescents. Methods: A nationwide sample of 14,537 high school students in urban areas of China was recruited. Information concerning suicide ideation, plans, attempts, trait aggression and other risk factors was collected by a self-reported questionnaire. Multivariate regression analyses were employed to predict suicidal behavior. Results: Approximately 18.5 % of students reported suicide ideation, 8.7 % reported suicide plans, and 4.1 % reported attempts during the past one year. Hostility and trait anger had a significant positive association with suicidal ideation. Hostility and physical aggression were positively related to suicide plans. Hostility had a positive correlation with suicide attempts, while trait anger was inversely associated with suicide attempts. Conclusions: This study suggests that hostility, physical aggression and trait anger may be able to be used to predict suicidal behavior among adolescents. Suicide prevention programs should target at attenuating the severity of hostility, anger and physical aggression. But teachers and parents should also give close attention to students with low trait anger

    Estimating the Cost of Large Superconducting Thin Solenoid Magnets

    No full text
    The cost of thin superconducting solenoid magnets can be estimated if one knows the magnet stored energy, the magnetic field volume product or the overall mass of the superconducting coil and its cryostat. This report shows cost data collected since 1979 for large superconducting solenoid magnets used in high energy physics. These magnets are characterized in most cases by the use of indirect two phase helium cooling and a superconductor stabilizer of very pure aluminum. This correlation can be used for making a preliminary cost estimate of proposed one of a kind superconducting magnets. The magnet costs quoted include the power supply and quench protection system but the cost of the helium refrigerator and helium distribution system is not included in the estimated cost

    Estimating the True Accuracy of Diagnostic Tests for Dengue Infection Using Bayesian Latent Class Models

    Get PDF
    Background Accuracy of rapid diagnostic tests for dengue infection has been repeatedly estimated by comparing those tests with reference assays. We hypothesized that those estimates might be inaccurate if the accuracy of the reference assays is not perfect. Here, we investigated this using statistical modeling. Methods/Principal Findings Data from a cohort study of 549 patients suspected of dengue infection presenting at Colombo North Teaching Hospital, Ragama, Sri Lanka, that described the application of our reference assay (a combination of Dengue IgM antibody capture ELISA and IgG antibody capture ELISA) and of three rapid diagnostic tests (Panbio NS1 antigen, IgM antibody and IgG antibody rapid immunochromatographic cassette tests) were re-evaluated using Bayesian latent class models (LCMs). The estimated sensitivity and specificity of the reference assay were 62.0% and 99.6%, respectively. Prevalence of dengue infection (24.3%), and sensitivities and specificities of the Panbio NS1 (45.9% and 97.9%), IgM (54.5% and 95.5%) and IgG (62.1% and 84.5%) estimated by Bayesian LCMs were significantly different from those estimated by assuming that the reference assay was perfect. Sensitivity, specificity, PPV and NPV for a combination of NS1, IgM and IgG cassette tests on admission samples were 87.0%, 82.8%, 62.0% and 95.2%, respectively. Conclusions Our reference assay is an imperfect gold standard. In our setting, the combination of NS1, IgM and IgG rapid diagnostic tests could be used on admission to rule out dengue infection with a high level of accuracy (NPV 95.2%). Further evaluation of rapid diagnostic tests for dengue infection should include the use of appropriate statistical models

    Experimental Verification of the Fano Effect

    No full text
    • …
    corecore