18 research outputs found

    Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

    Get PDF
    Background: The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort.Methods: Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects' attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant.Results: There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques.Conclusions: Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques

    Pharmacological evidence for the stimulation of NADPH oxidase by P2X7 receptors in mouse submandibular glands

    Get PDF
    ATP in the 100 μM-1 mM concentration range provoked a calcium-independent increase of the oxidation of dichlorodihydrofluorescein (DCFH) to dichlorofluorescein (DCF) by mouse submandibular cells. 3′-O-(4-benzoyl)benzoyl adenosine 5′-triphosphate (BzATP), a P2X7 agonist, but not a muscarinic or an adrenergic agonist, reproduced the effect of ATP. The inhibition of phospholipase C by U73122 or the potentiation of P2X4 receptor activation with ivermectin did not modify the response to ATP. ATP did not increase the oxidation of DCFH in cells isolated from submandibular glands of P2X7 knockout mice or in cells pretreated with a P2X7 antagonist. The inhibition of protein kinase C or of mitogen-activated protein kinase (MAP kinase) or of reduced nicotinamide adenine dinucleotide phosphate (NADPH) oxidase blocked the oxidation of DCFH without affecting the increase of the intracellular concentration of calcium or the uptake of ethidium bromide in response to extracellular ATP. From these results it is concluded that the activation of the P2X7 receptors from submandibular glands triggers an intracellular signalling cascade involving protein kinase C and MAP kinase leading to the stimulation of NADPH oxidase and the subsequent generation of reactive oxygen species

    Accuracy and Reliability of Intraoral Scanners: Are They the Better Option?

    No full text
    Purpose of Review The aim was to compare the accuracy of digital intraoral impressions with conventional impressions on the fabrication of different types of restorations. This study also compared the accuracy, reliability, and ease of use of different types of intraoral scanners available and correlated the results with the different scanning technologies.Recent Findings Digital impressions offer the same level of accuracy as conventional impressions regarding fabrication of crowns, fixed dental prostheses (FDPs), implant-supported crowns, and short-span FDPs with marginal gap values within the clinically acceptable range (<120 μm). However, for full- arch restorations, conventional impressions result in better accuracy.Summary Further enhancements needs to be undertaken re- garding intraoral scanners to improve its accuracy regarding fabrication of full-arch restorations. Further in vivo studies evaluating the accuracy of intraoral digital impressions on the fabrication of a wider range of restorations such as inlays, veneers, and full-arch restoration need to be conducted
    corecore