78 research outputs found

    Electromyographic activity of trunk muscles during exercises with flexible and non-flexible poles

    Get PDF
    Objective: Hand-held flexible poles which are brought into oscillation to cause alternating forces on trunk, are advocated as training devices that are supposed to solicit increased levels of stabilizing trunk muscle activity. The aim of this study was to verify this claim by comparing electromyographic (EMG) activity of trunk muscles during exercises performed with a flexible pole and a rigid pole. Methods: Twelve healthy females performed three different exercises with flexible and rigid poles. EMG activity of iliocostalis lumborum (IL), multifidus (MU), rectus abdominis (RA), external oblique (EO) and internal oblique (IO), and was continuously measured. The EMG signals were analyzed in time domain by calculation of the Root Mean Square (RMS) amplitudes over 250 ms windows. The mean RMS-values over time were normalized by the maximum RMS obtained for each muscle. Results: The IO showed a 72% greater EMG activity during the exercises performed with the flexible pole than with the rigid pole (p=0.035). In exercises performed in standing, the IO was significantly more active than when sitting (p=0.006). Conclusion: As intended, the cyclic forces induced by the oscillating pole did increase trunk muscle activation. However, the effect was limited and significant for the IO muscle only. © 2011 - IOS Press and the authors

    Electromyographic activity of shoulder muscles during exercises performed with oscillatory and non-oscillatory poles

    Get PDF
    BACKGROUND: Pain and dysfunction of the shoulder complex are commonly found physiotherapy practice. These musculoskeletal abnormalities are related to instability and inadequate kinematic function, that depend on the integrity of the muscle tissues. Thus, to enhance the results of exercise therapies, and prevent and attenuate pain and dynfunction, the use of oscillatory pole has been implemented in clinical practice. OBJECTIVES: The purpose of this study was to analyze the electromyographic (EMG) activity of shoulder stabilizing muscles during exercises performed with an oscillatory and a non-oscillatory pole. METHODS: Twelve female volunteers, aged 20.4 years±1.9, participated in this study. EMG data were collected from upper trapezius (UT), lower trapezius (LT) and middle deltoid (MD) during three different exercises with an oscillatory and a non-oscillatory pole. The EMG signals were analyzed in the time domain through the calculation of Root Mean Square (RMS). The RMS values were normalized by the peak value obtained over all trials for each muscle. Statistical analysis was performed with repeated measures ANOVA and post-hoc of Bonferroni tests. RESULTS: The EMG activity of UT, LT and MD muscles were significantly higher with the oscillatory pole than the non-oscillatory pole (all p<0,001). There were no significant differences in the activation of these muscles between exercises. CONCLUSION: The results of the present study indicated that the oscillatory pole does require higher activation of the shoulder muscles and therefore, may be useful in the training of the shoulder complex

    Scaling predictions for radii of weakly bound triatomic molecules

    Full text link
    The mean-square radii of the molecules 4^4He3_3, 4^4He26_2-^6Li, 4^4He27_2-^7Li and 4^4He223_2-^{23}Na are calculated using a three-body model with contact interactions. They are obtained from a universal scaling function calculated within a renormalized scheme for three particles interacting through pairwise Dirac-delta interaction. The root-mean-square distance between two atoms of mass mAm_A in a triatomic molecule are estimated to be of de order of C2/[mA(E3E2)]{\cal C}\sqrt{\hbar^2/[m_A(E_3-E_2)]}, where E2E_2 is the dimer and E3E_3 the trimer binding energies, and C{\cal C} is a constant (varying from 0.6\sim 0.6 to 1\sim 1) that depends on the ratio between E2E_2 and E3E_3. Considering previous estimates for the trimer energies, we also predict the sizes of Rubidium and Sodium trimers in atomic traps.Comment: 7 pages, 2 figure
    corecore