Emulsion sheet doublets as interface trackers for the OPERA experiment
New methods for efficient and unambiguous interconnection between electronic
counters and target units based on nuclear photographic emulsion films have
been developed. The application to the OPERA experiment, that aims at detecting
oscillations between mu neutrino and tau neutrino in the CNGS neutrino beam, is
reported in this paper. In order to reduce background due to latent tracks
collected before installation in the detector, on-site large-scale treatments
of the emulsions ("refreshing") have been applied. Changeable Sheet (CSd)
packages, each made of a doublet of emulsion films, have been designed,
assembled and coupled to the OPERA target units ("ECC bricks"). A device has
been built to print X-ray spots for accurate interconnection both within the
CSd and between the CSd and the related ECC brick. Sample emulsion films have
been extensively scanned with state-of-the-art automated optical microscopes.
Efficient track-matching and powerful background rejection have been achieved
in tests with electronically tagged penetrating muons. Further improvement of
in-doublet film alignment was obtained by matching the pattern of low-energy
electron tracks. The commissioning of the overall OPERA alignment procedure is
in progress.Comment: 19 pages, 19 figure
Measurement of the atmospheric muon charge ratio with the OPERA detector
The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used
to measure the atmospheric muon charge ratio in the TeV energy region. We
analyzed 403069 atmospheric muons corresponding to 113.4 days of livetime
during the 2008 CNGS run. We computed separately the muon charge ratio for
single and for multiple muon events in order to select different energy regions
of the primary cosmic ray spectrum and to test the charge ratio dependence on
the primary composition. The measured charge ratio values were corrected taking
into account the charge-misidentification errors. Data have also been grouped
in five bins of the "vertical surface energy". A fit to a simplified model of
muon production in the atmosphere allowed the determination of the pion and
kaon charge ratios weighted by the cosmic ray energy spectrum.Comment: 14 pages, 10 figure
First events from the CNGS neutrino beam detected in the OPERA experiment
The OPERA neutrino detector at the underground Gran Sasso Laboratory (LNGS)
was designed to perform the first detection of neutrino oscillations in
appearance mode, through the study of nu_mu to nu_tau oscillations. The
apparatus consists of a lead/emulsion-film target complemented by electronic
detectors. It is placed in the high-energy, long-baseline CERN to LNGS beam
(CNGS) 730 km away from the neutrino source. In August 2006 a first run with
CNGS neutrinos was successfully conducted. A first sample of neutrino events
was collected, statistically consistent with the integrated beam intensity.
After a brief description of the beam and of the various sub-detectors, we
report on the achievement of this milestone, presenting the first data and some
analysis results.Comment: Submitted to the New Journal of Physic
The detection of neutrino interactions in the emulsion/lead target of the OPERA experiment
The OPERA neutrino detector in the underground Gran Sasso Laboratory (LNGS)
was designed to perform the first detection of neutrino oscillations in
appearance mode through the study of oscillations. The
apparatus consists of an emulsion/lead target complemented by electronic
detectors and it is placed in the high energy long-baseline CERN to LNGS beam
(CNGS) 730 km away from the neutrino source. Runs with CNGS neutrinos were
successfully carried out in 2007 and 2008 with the detector fully operational
with its related facilities for the emulsion handling and analysis. After a
brief description of the beam and of the experimental setup we report on the
collection, reconstruction and analysis procedures of first samples of neutrino
interaction events
Clinical Usefulness of Multiplex PCR Lateral Flow in MRSA Detection: A Novel, Rapid Genetic Testing Method
Methicillin-resistant Staphylococcus aureus (MRSA) with exogenous cassette DNA containing the methicillin-resistant gene mecA (SCCmec) poses a problem as a drug-resistant bacterium responsible for hospital- and community-acquired infections. The frequency of MRSA detection has recently been increasing rapidly in Japan, and SCCmec has also been classified more diversely into types I–V. A rapid test is essential for early diagnosis and treatment of MRSA infections, but detection by conventional methods requires at least two days. The newly developed multiplex PCR lateral flow method allows specific amplification of femA to detect S. aureus, mecA to detect SCCmec, and kdpC to detect SCCmec type II; moreover, PCR products can be evaluated visually in about 3 h. In the present study, we developed a PCR lateral flow method for MRSA using this method and investigated its clinical usefulness in the detection of MRSA. The results showed a diagnostic concordance rate of 91.7% for MRSA and methicillin-susceptible S. aureus between bacteriological examination and PCR lateral flow, and a high level of specificity in PCR lateral flow. In addition, a higher detection rate for S. aureus using the same sample was observed for PCR lateral flow (70.2%) than for bacteriological tests (48.6%). The above results show that PCR lateral flow for MRSA detection has high sensitivity, specificity, and speed, and its clinical application as a method for early diagnosis of MRSA infections appears to be feasible
Hyperactive S6K1 Mediates Oxidative Stress and Endothelial Dysfunction in Aging: Inhibition by Resveratrol
Mammalian target of rapamycin (mTOR)/S6K1 signalling emerges as a critical regulator of aging. Yet, a role of mTOR/S6K1 in aging-associated vascular endothelial dysfunction remains unknown. In this study, we investigated the role of S6K1 in aging-associated endothelial dysfunction and effects of the polyphenol resveratrol on S6K1 in aging endothelial cells. We show here that senescent endothelial cells displayed higher S6K1 activity, increased superoxide production and decreased bioactive nitric oxide (NO) levels than young endothelial cells, which is contributed by eNOS uncoupling. Silencing S6K1 in senescent cells reduced superoxide generation and enhanced NO production. Conversely, over-expression of a constitutively active S6K1 mutant in young endothelial cells mimicked endothelial dysfunction of the senescent cells through eNOS uncoupling and induced premature cellular senescence. Like the mTOR/S6K1 inhibitor rapamycin, resveratrol inhibited S6K1 signalling, resulting in decreased superoxide generation and enhanced NO levels in the senescent cells. Consistent with the data from cultured cells, an enhanced S6K1 activity, increased superoxide generation, and decreased bioactive NO levels associated with eNOS uncoupling were also detected in aortas of old WKY rats (aged 20–24 months) as compared to the young animals (1–3 months). Treatment of aortas of old rats with resveratrol or rapamycin inhibited S6K1 activity, oxidative stress, and improved endothelial NO production. Our data demonstrate a causal role of the hyperactive S6K1 in eNOS uncoupling leading to endothelial dysfunction and vascular aging. Resveratrol improves endothelial function in aging, at least in part, through inhibition of S6K1. Targeting S6K1 may thus represent a novel therapeutic approach for aging-associated vascular disease
Study of the effects induced by lead on the emulsion films of the OPERA experiment
The OPERA neutrino oscillation experiment is based on the use of the Emulsion
Cloud Chamber (ECC). In the OPERA ECC, nuclear emulsion films acting as very
high precision tracking detectors are interleaved with lead plates providing a
massive target for neutrino interactions. We report on studies related to the
effects occurring from the contact between emulsion and lead. A low
radioactivity lead is required in order to minimize the number of background
tracks in emulsions and to achieve the required performance in the
reconstruction of neutrino events. It was observed that adding other chemical
elements to the lead, in order to improve the mechanical properties, may
significantly increase the level of radioactivity on the emulsions. A detailed
study was made in order to choose a lead alloy with good mechanical properties
and an appropriate packing technique so as to have a low enough effective
radioactivity.Comment: 19 pages, 11 figure
Observation of a first candidate in the OPERA experiment in the CNGS beam
The OPERA neutrino detector in the underground Gran Sasso Laboratory (LNGS)
has been designed to perform the first detection of neutrino oscillations in
direct appearance mode through the study of the
channel. The hybrid apparatus consists of an emulsion/lead target complemented
by electronic detectors and it is placed in the high energy long-baseline CERN
to LNGS beam (CNGS) 730 km away from the neutrino source. Runs with CNGS
neutrinos were successfully carried out in 2008 and 2009. After a brief
description of the beam, the experimental setup and the procedures used for the
analysis of the neutrino events, we describe the topology and kinematics of a
first candidate charged-current event satisfying the kinematical
selection criteria. The background calculations and their cross-check are
explained in detail and the significance of the event is assessed.Comment: 19 pages, 3 figure