43 research outputs found
Recommended from our members
Lab on a stick: multi-analyte cellular assays in a microfluidic dipstick
A new microfluidic concept for multi-analyte testing in a dipstick format is presented, termed “Lab-on-a-Stick”, that combines the simplicity of dipstick tests with the high performance of microfluidic devices. Lab-on-a-Stick tests are ideally suited to analysis of particulate samples such as mammalian or bacterial cells, and capable of performing multiple different parallel microfluidic assays when dipped into a single sample with results recorded optically. The utility of this new diagnostics format was demonstrated by performing three types of multiplex cellular assays that are challenging to perform in conventional dipsticks: 1) instantaneous ABO blood typing; 2) microbial identification; and 3) antibiotic minimum inhibitory (MIC) concentration measurement. A pressure balance model closely predicted the superficial flow velocities in individual capillaries, that were overestimated by up to one order of magnitude by the Lucas-Washburn equation conventionally used for wicking in cylindrical pores. Lab-on-a-stick provides a cost-effective, simple, portable and flexible multiplex platform for a range of assays, and will deliver a new generation of advanced yet affordable point-of-care tests for global diagnostics
Nocardia transvalensis keratitis: an emerging pathology among travelers returning from Asia
<p>Abstract</p> <p>Background</p> <p>The incidence rate of <it>Nocardia </it>keratitis is increasing, with new species identified thanks to molecular methods. We herein report a case of <it>Nocardia transvalensis </it>keratitis, illustrating this emerging pathology among travellers returning from Asia.</p> <p>Case presentation</p> <p>A 23-year-old man presented with a 10-week history of ocular pain, redness, and blurred vision in his right eye following a projectile foreign body impacting the cornea while motor biking in ThaĂŻland. At presentation, a central epithelial defect with a central whitish stromal infiltrate associated with pinhead satellite infiltrates was observed. Identification with 16S rRNA PCR sequencing and microbiological culture of corneal scraping and revealed <it>N. transvalensis </it>as the causative organism. Treatment was initiated with intensive topical amikacin, oral ketoconazole and oral doxycycline. After a four-week treatment period, the corneal infiltrate decreased so that only a faint subepithelial opacity remained.</p> <p>Conclusion</p> <p><it>Nocardia </it>organisms should be suspected as the causative agent of any case of keratitis in travelers returning from Asia. With appropriate therapy, <it>Nocardia </it>keratitis resolves, resulting in good visual outcome.</p
Revolutionizing Clinical Microbiology Laboratory Organization in Hospitals with In Situ Point-of-Care
BACKGROUND: Clinical microbiology may direct decisions regarding hospitalization, isolation and anti-infective therapy, but it is not effective at the time of early care. Point-of-care (POC) tests have been developed for this purpose. METHODS AND FINDINGS: One pilot POC-lab was located close to the core laboratory and emergency ward to test the proof of concept. A second POC-lab was located inside the emergency ward of a distant hospital without a microbiology laboratory. Twenty-three molecular and immuno-detection tests, which were technically undemanding, were progressively implemented, with results obtained in less than four hours. From 2008 to 2010, 51,179 tests yielded 6,244 diagnoses. The second POC-lab detected contagious pathogens in 982 patients who benefited from targeted isolation measures, including those undertaken during the influenza outbreak. POC tests prevented unnecessary treatment of patients with non-streptococcal tonsillitis (n = 1,844) and pregnant women negative for Streptococcus agalactiae carriage (n = 763). The cerebrospinal fluid culture remained sterile in 50% of the 49 patients with bacterial meningitis, therefore antibiotic treatment was guided by the molecular tests performed in the POC-labs. With regard to enterovirus meningitis, the mean length-of-stay of infected patients over 15 years old significantly decreased from 2008 to 2010 compared with 2005 when the POC was not in place (1.43±1.09 versus 2.91±2.31 days; p = 0.0009). Altogether, patients who received POC tests were immediately discharged nearly thrice as often as patients who underwent a conventional diagnostic procedure. CONCLUSIONS: The on-site POC-lab met physicians' needs and influenced the management of 8% of the patients that presented to emergency wards. This strategy might represent a major evolution of decision-making regarding the management of infectious diseases and patient care
Imaging device with image acquisition rate optimization
<p> The disclosure includes a method of acquiring high-resolution ultrasound images using an array of transducers using successive transmission matrices. </p
Multicenter analytical performance evaluation of a fully automated anti-MĂĽllerian hormone assay and reference interval determination
Objectives: Anti-Müllerian hormone (AMH) is an established biomarker for assessing ovarian reserve and predicting response to controlled ovarian stimulation. Its routine clinical use is hampered by the variability and low-throughput of available enzyme-linked immunosorbent assays (ELISA). The presented study examined if a fully automated AMH electrochemiluminescence assay (ECLIA; Elecsys® AMH assay, Roche Diagnostics) was suitable for measuring AMH levels in healthy women and in those diagnosed with polycystic ovary syndrome (PCOS). Design andmethods: Five European laboratories evaluated the Elecsys® AMH assay independently under routine conditions over eightmonths. Within-run imprecision, repeatability, intermediate precision, linearity and functional sensitivity were assessed. The Elecsys® AMH assay was compared to a manual ELISA microtiter plate format test (AMH Gen II ELISA,modified version; Beckman Coulter Inc.) using 1729 routine serum samples. AMH reference intervals were determined in 887 healthy women with regularmenstrual cycle aged 20-50 years, and 149 women diagnosed with PCOS. Results: The fully automated Elecsys® AMH assay showed excellent precision, linearity, and functional sensitivity. The coefficient of variationwas 1.8% for repeatability and 4.4% for intermediate precision. Values measured with the Elecsys® AMH assay were highly correlated with the manual ELISA method (modified version) but 24-28% lower. Reference intervals showed the expected AMH decline with age in healthy women and increased AMH levels in women with PCOS. Conclusions: The Elecsys® AMH assay demonstrated good precision under routine conditions, and is suitable for determining AMH levels in serum and lithium-heparin plasma