8 research outputs found

    Cholesterol Corrects Altered Conformation of MHC-II Protein in Leishmania donovani Infected Macrophages: Implication in Therapy

    Get PDF
    Previously we reported that Kala-azar patients show progressive decrease in serum cholesterol as a function of splenic parasite burden. Splenic macrophages (MΦ) of Leishmania donovani (LD) infected mice show decrease in membrane cholesterol, while LD infected macrophages (I-MΦ) show defective T cell stimulating ability that could be corrected by liposomal delivery of cholesterol. T helper cells recognize peptide antigen in the context of class II MHC molecule. It is known that the conformation of a large number of membrane proteins is dependent on membrane cholesterol. In this investigation we tried to understand the influence of decreased membrane cholesterol in I-MΦ on the conformation of MHC-II protein and peptide-MHC-II stability, and its bearing on the antigen specific T-cell activatio

    Cutting Planes and a Biased Newton Direction for Minimizing Quasiconvex Functions

    No full text
    H. Scolnik 2 A biased Newton direction is introduced for minimizing quasiconvex functions with bounded level sets. It is a generalization of the usual Newton's direction for strictly convex quadratic functions. This new direction can be derived from the intersection of approximating hyperplanes to the epigraph at points on the boundary of the same level set. Based on that direction, an unconstrained minimization algorithm is presented. It is proved to have global and local-quadratic convergence under standard hypotheses. These theoretical results may lead to di erent methods based oncomputing search directions using only rst order information at points on the level sets. Most of all if the computational cost can be reduced byrelaxing some of the conditions according for instance totheresults presented intheAppendix. Some tests are presented to show the qualitative behavior of the new direction and with the purpose to stimulate further research on these kind of algorithms

    Single gas chromatography method with nitrogen phosphorus detector for urinary cotinine determination in passive and active smokers

    Get PDF
    Nicotine is a major addictive compound in cigarettes and is rapidly and extensively metabolized to several metabolites in humans, including urinary cotinine, considered a biomarker due to its high concentration compared to other metabolites. The aim of this study was to develop a single method for determination of urinary cotinine, in active and passive smokers, by gas chromatography with a nitrogen phosphorus detector (GC-NPD). Urine (5.0 mL) was extracted with 1.0 mL of sodium hydroxide 5 mol L-1, 5.0 mL of chloroform, and lidocaine used as the internal standard. Injection volume was 1 &#956;L in GC-NPD. Limit of quantification was 10 ng mL-1. Linearity was evaluated in the ranges 10-1000 ng mL-1 and 500-6000 ng mL-1, with determination coefficients of 0.9986 and 0.9952, respectively. Intra- and inter-assay standard relative deviations were lower than 14.2 %, while inaccuracy (bias) was less than +11.9%. The efficiency of extraction was greater than 88.5%. Ruggedness was verified, according to Youden's test. Means of cotinine concentrations observed were 2,980 ng mL-1 for active smokers and 132 ng mL-1, for passive smokers. The results revealed that satisfactory chromatographic separation between the analyte and interferents was obtained with a ZB-1 column. This method is reliable, precise, linear and presented ruggedness in the range evaluated. The results suggest that it can be applied in routine analysis for passive and active smokers, since it is able to quantify a wide range of cotinine concentrations in urine.<br>A nicotina é uma substância presente no cigarro capaz de causar dependência, sendo biotransformada em vários metabólitos nos seres humanos, dentre eles a cotinina urinária, que é considerada um indicador biológico de exposição à nicotina, devido a suas altas concentrações, comparado a outras matrizes. Assim, o objetivo deste estudo foi desenvolver um único método para determinação de cotinina urinária, em amostras de urina de fumantes ativos e passivos, através de cromatografia em fase gasosa com detector de nitrogênio- fósforo (CG-DNF). Para o preparo de amostras foram utilizados 5 mL de urina, 1 mL de hidróxido de sódio 5 mol L-1, 5 mL de clorofórmio, tendo como padrão interno a lidocaína. Na faixa de concentrações de 10-1000 ng mL-1 e 500- 6000 ng mL-1, o coeficiente de determinação foi 0,9986 e 0,9952, respectivamente e, o limite de quantificação foi 10 ng mL-1. A precisão intra- e interensaio apresentou desvio padrão relativo (%) menor que 14,2% e a inexatidão foi menor que +11,9%, com uma eficiência de extração de 88,5%. O método apresentou robustez, de acordo com o teste de Youden. As concentrações médias de cotinina observadas foram 2980 ng mL-1, para fumantes ativos e 132 ng mL-1, para fumantes passivos. Os resultados sugerem que o método é confiável, preciso, linear e apresentou robustez, na faixa avaliada, podendo ser aplicado na rotina para análises de amostras de fumantes ativos e passivos, pois é capaz de quantificar uma ampla faixa de concentrações de cotinina urinária

    Asymmetric architecture is non-random and repeatable in a bird’s nests

    No full text

    Hepatitis A Virus

    No full text
    corecore