282 research outputs found
Breath-hold MR cholangiopancreatography with three-dimensional, segmented, echo-planar imaging and volume rendering
End-expiration, 21-second breath-hold, three-dimensional magnetic
resonance (MR) cholangiopancreatography (MRCP) was developed with
segmented echo-planar imaging. In 15 healthy subjects and 14 randomly
selected patients undergoing liver studies, three-dimensional MRCP images
were obtained and volume rendered. In 15 (100%) healthy subjects and 13
(93%) patients, clear depiction of biliary, hepatic, and pancreatic ducts
(with lumen diameter of at least 2 mm) was possible with good
signal-to-noise ratio
Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography.
Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR).This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients(median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (j = 0.73). To identify relevant,more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging
Ď€-Conjugated Donor-Acceptor Systems as Metal-Free Sensitizers for Dye-Sensitized Solar Cell Applications
High extinction coefficients and easily tunable spectral properties of π - conjugated donor-acceptor dyes are of superior advantage for the design of new metal- free organic sensitizers for applications in dye-sensitized solar cells. Ultrafast transient absorption spectroscopy on the femtosecond and nanosecond time scales provided deep insights into the dependence of charge carrier dynamics in fully organic dye/TiO2 systems on i) the donor-acceptor distance, ii) the π-conjugation length, and iii) the coupling to TiO2 by different anchoring groups. Importantly, the observed differences in charge transfer dynamics justify the variations of photovoltaic performances of the dyes as applied in solar cell devices. This leads to the conclusion that the photoconversion efficiencies strongly depend on a delicate interplay between the dyes’ building blocks, i.e. the donor, the π-conjugated spacer and the anchor/acceptor moieties, and may easily be tuned by molecular design
Recommended from our members
Considerations for patient positioning in static beams for BNCT
The objective of this short communication is to provide a guideline for patient positioning, verification, and immobilization for boron neutron capture therapy
The use of chest magnetic resonance imaging in interstitial lung disease: A systematic review
Thin-slices multi-detector computed tomography (MDCT) plays a key role in the differential diagnosis of interstitial lung disease (ILD). However, thin-slices MDCT has a limited ability to detect active inflammation, which is an important target of newly developed ILD drug therapy. Magnetic resonance imaging (MRI), thanks to its multi-parameter capability, provides better tissue characterisation than thin-slices MDCT. Our aim was to summarise the current status of MRI applications in ILD and to propose an ILD-MRI protocol. A systematic literature search was conducted for relevant studies on chest MRI in patients with ILD. We retrieved 1246 papers of which 55 original papers were selected for the review. We identified 24 studies comparing image quality of thin-slices MDCT and MRI using several MRI sequences. These studies described new MRI sequences to assess ILD parenchymal abnormalities, such as honeycombing, reticulation and ground-glass opacity. Thin-slices MDCT remains superior to MRI for morphological imaging. However, recent studies with ultra-short echo-time MRI showed image quality comparable to thin-slices MDCT. Several studies demonstrated the added value of chest MRI by using functional imaging, especially to detect and quantify inflammatory changes. We concluded that chest MRI could play a role in ILD patients to differentiate inflammatory and fibrotic changes and to assess efficacy of new ILD drugs
Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast-enhanced MRI
Both inflow and the partial volume effect (PVE) are sources of error when measuring the arterial input function (AIF) in dynamic contrast-enhanced (DCE) MRI. This is relevant, as errors in the AIF can propagate into pharmacokinetic parameter estimations from the DCE data. A method was introduced for flow correction by estimating and compensating the number of the perceived pulse of spins during inflow. We hypothesized that the PVE has an impact on concentration–time curves similar to inflow. Therefore, we aimed to study the efficiency of this method to compensate for both effects simultaneously. We first simulated an AIF with different levels of inflow and PVE contamination. The peak, full width at half-maximum (FWHM), and area under curve (AUC) of the reconstructed AIFs were compared with the true (simulated) AIF. In clinical data, the PVE was included in AIFs artificially by averaging the signal in voxels surrounding a manually selected point in an artery. Subsequently, the artificial partial volume AIFs were corrected and compared with the AIF from the selected point. Additionally, corrected AIFs from the internal carotid artery (ICA), the middle cerebral artery (MCA), and the venous output function (VOF) estimated from the superior sagittal sinus (SSS) were compared. As such, we aimed to investigate the effectiveness of the correction method with different levels of inflow and PVE in clinical data. The simulation data demonstrated that the corrected AIFs had only marginal bias in peak value, FWHM, and AUC. Also, the algorithm yielded highly correlated reconstructed curves over increasingly larger neighbourhoods surrounding selected arterial points in clinical data. Furthermore, AIFs measured from the ICA and MCA produced similar peak height and FWHM, whereas a significantly larger peak and lower FWHM was found compared with the VOF. Our findings indicate that the proposed method has high potential to compensate for PVE and inflow simultaneously. The corrected AIFs could thereby provide a stable input source for DCE analysis.</p
MR coronary angiography with breath-hold targeted volumes: preliminary clinical results
PURPOSE: To assess the clinical value of a magnetic resonance (MR)
coronary angiography strategy involving a small targeted volume to image
one coronary segment in a single breath hold for the detection of greater
than 50% stenosis. MATERIALS AND METHODS: Thirty-eight patients referred
for elective coronary angiography were included. The coronary arteries
were localized during single-breath-hold, three-dimensional imaging of the
entire heart. MR coronary angiography was then performed along the major
coronary branches with a double-oblique, three-dimensional, gradient-echo
sequence. Conventional coronary angiography was the reference-standard
method. RESULTS: Adequate visualization was achieved with MR coronary
angiography in 85%-91% of the proximal coronary arterial branches and in
38%-76% of the middle and distal branches. Overall, 187 (69%) of 272
segments were suitable for comparison between conventional and MR coronary
angiography. The diagnostic accuracy of MR coronary angiography for the
detection of hemodynamically significant stenoses was 92%; sensitivity,
68%; and specificity, 97%. The sensitivity in individual segments was
50%-77%, whereas the specificity was 94%-100%. CONCLUSION: Adequate
visualization of the major coronary arterial branches was possible in the
majority of patients. The observed accuracy of MR coronary angiography for
detection of hemodynamically significant coronary arterial stenosis is
promising, but it needs to be higher before this modality can be used
reliably in a clinical setting
- …