175 research outputs found

    A random forest approach to estimate daily particulate matter, nitrogen dioxide, and ozone at fine spatial resolution in Sweden

    Get PDF
    Air pollution is one of the leading causes of mortality worldwide. An accurate assessment of its spatial and temporal distribution is mandatory to conduct epidemiological studies able to estimate long-term (e.g., annual) and short-term (e.g., daily) health effects. While spatiotemporal models for particulate matter (PM) have been developed in several countries, estimates of daily nitrogen dioxide (NO 2 ) and ozone (O 3 ) concentrations at high spatial resolution are lacking, and no such models have been developed in Sweden. We collected data on daily air pollutant concentrations from routine monitoring networks over the period 2005-2016 and matched them with satellite data, dispersion models, meteorological parameters, and land-use variables. We developed a machine-learning approach, the random forest (RF), to estimate daily concentrations of PM 10 (PM<10 microns), PM 2.5 (PM<2.5 microns), PM 2.5-10 (PM between 2.5 and 10 microns), NO 2 , and O 3 for each squared kilometer of Sweden over the period 2005-2016. Our models were able to describe between 64% (PM 10 ) and 78% (O 3 ) of air pollutant variability in held-out observations, and between 37% (NO 2 ) and 61% (O 3 ) in held-out monitors, with no major differences across years and seasons and better performance in larger cities such as Stockholm. These estimates will allow to investigate air pollution effects across the whole of Sweden, including suburban and rural areas, previously neglected by epidemiological investigation

    Ultralong Copper Phthalocyanine Nanowires with New Crystal Structure and Broad Optical Absorption

    Full text link
    The development of molecular nanostructures plays a major role in emerging organic electronic applications, as it leads to improved performance and is compatible with our increasing need for miniaturisation. In particular, nanowires have been obtained from solution or vapour phase and have displayed high conductivity, or large interfacial areas in solar cells. In all cases however, the crystal structure remains as in films or bulk, and the exploitation of wires requires extensive post-growth manipulation as their orientations are random. Here we report copper phthalocyanine (CuPc) nanowires with diameters of 10-100 nm, high directionality and unprecedented aspect ratios. We demonstrate that they adopt a new crystal phase, designated eta-CuPc, where the molecules stack along the long axis. The resulting high electronic overlap along the centimetre length stacks achieved in our wires mediates antiferromagnetic couplings and broadens the optical absorption spectrum. The ability to fabricate ultralong, flexible metal phthalocyanine nanowires opens new possibilities for applications of these simple molecules

    Studying radiation hardness of a cadmium tungstate crystal based radiation detector

    Get PDF
    The given article considers radiation hardness of an X-ray detector used in production of non-destructive testing instruments and inspection systems. In the course of research, experiments were carried out to estimate radiation hardness of a detector based on cadmium tungstate crystal and its structural components individually. The article describes a layout of an experimental facility that was used for measurements of radiation hardness. The radiation dose dependence of the photodiode current is presented, when it is excited by a light flux of a scintillator or by an external light source. Experiments were carried out to estimate radiation hardness of two types of optical glue used in detector production; they are based on silicon rubber and epoxy. With the help of a spectrophotometer and cobalt gun, each of the glue samples was measured for a relative light transmission factor with different wavelengths, depending on the radiation dose. The obtained data are presented in a comprehensive analysis of the results. It was determined, which of the glue samples is most suitable for production of detectors working under exposure to strong radiation

    Taking the strain? Impact of glaucoma on patients' informal caregivers

    Get PDF
    Purpose: To estimate informal caregiver (ICG) strain in people from a glaucoma clinic. Methods: Patients with glaucoma were consecutively identified from a single clinic in England for a cross-sectional postal survey. The sample was deliberately enriched with a number of patients designated as having advanced glaucoma (visual field [VF] mean deviation worse than -12 dB in both eyes). Patients were asked to identify an ICG who recorded a Modified Caregiver Strain Index (MCSI), a validated 13 item instrument scored on a scale of 0-26. Previous research has indicated mean MCSI to be >10 in Multiple Sclerosis and Parkinson’s disease. All participants gave a self-reported measure of general health (EQ5D). Results: Responses from 105 patients (43% of those invited) were analysed; only 38 of the 105 named an ICG. Mean (95% confidence interval [CI]) MCSI was 2.4 (1.3, 3.6) and only three ICGs recorded a MCSI > 7. The percentage of patients with an ICG was much higher in patients with advanced VF loss (82%; 9/11) when compared to those with non-advanced VF loss (31%; 29/94; p=0.001). Mean (standard deviation) MCSI was considerably inflated in the advanced patients (5.6 [4.9] vs 1.5 [2.2] for non-advanced; p=0.040). Worsening VF and poorer self-reported general health (EQ5D) of the patient were associated with worsening MCSI. Conclusion: ICG strain, as measured by MCSI, for patients with non-advanced glaucoma is negligible, compared to other chronic disease. ICG strain increases moderately with worsening VFs but this could be partly explained by worse general health in our sample of patients

    Depth Profiling Photoelectron-Spectroscopic Study of an Organic Spin Valve with a Plasma-Modified Pentacene Spacer

    Get PDF
    [[abstract]]We report an enhanced magnetoresistance (MR) in an organic spin valve with an oxygen plasma-treated pentacene (PC) spacer. The spin valve containing PC without the treatment shows no MR effect, whereas those with moderately plasma-treated PC exhibit MR ratios up to 1.64% at room temperature. X-ray photoelectron spectroscopy with depth profiling is utilized to characterize the interfacial electronic properties of the plasma-treated PC spacer which shows the formation of a derivative oxide layer. The results suggest an alternative approach to improve the interface quality and in turn to enhance the MR performance in organic spin valves.[[incitationindex]]SCI[[booktype]]電子

    Stencil Nano Lithography Based on a Nanoscale Polymer Shadow Mask: Towards Organic Nanoelectronics

    Get PDF
    A stencil lithography technique has been developed to fabricate organic-material-based electronic devices with sub-micron resolution. Suspended polymethylmethacrylate ( PMMA) membranes were used as shadow masks for defining organic channels and top electrodes. Arrays of pentacene field effect transistors (FETs) with various channel lengths from 50 mu m down to 500 nm were successfully produced from the same batch using this technique. Electrical transport measurements showed that the electrical contacts of all devices were stable and the normalized contact resistances were much lower than previously studied organic FETs. Scaling effects, originating from the bulk space charge current, were investigated by analyzing the channel-length-dependent mobility and hysteresis behaviors. This novel lithography method provides a reliable means for studying the fundamental transport properties of organic materials at the nanoscale as well as enabling potential applications requiring the fabrication of integrated organic nanoelectronic devices.open1155sciescopu

    Actinomyces Infectious Crystalline Keratopathy

    No full text

    Stresses and deformations around a supported pit shaft

    No full text
    corecore