78 research outputs found

    Developing a Questionnaire for Iranian Women's Attitude on Medical Ethics in Vaginal Childbirth

    Get PDF
    Background: Vaginal delivery is one of the challenging issues in medical ethics. It is important to use an appropriate instrument to assess medical ethics attitudes in normal delivery, but the lack of tool for this purpose is clear. Objectives: The aim of this study was to develop and validate a questionnaire for the assessment of women’s attitude on medical ethics application in normal vaginal delivery. Patients and Methods: This methodological study was carried out in Iran in 2013 - 2014. Medical ethics attitude in vaginal delivery questionnaire (MEAVDQ) was developed using the findings of a qualitative data obtained from a grounded theory research conducted on 20 women who had vaginal childbirth, in the first phase. Then, the validation criteria of this tool were tested by content and face validity in the second phase. Exploratory factor analysis was used for construct validity and reliability was also tested by Cronbach’s alpha coefficient in the third phase of this study. SPSS version 13 was used in this study. The sample size for construct validity was 250 females who had normal vaginal childbirth. Results: In the first phase of this study (tool development), by the use of four obtained categories and nine subcategories from grounded theory and literature review, three parts (98-items) of this tool were obtained (A, B and J). Part A explained the first principle of medical ethics, part B pointed to the second and third principles of medical ethics, and part J explained the fourth principle of medical ethics. After evaluating and confirming its face and content validity, 75 items remained in the questionnaire. In construct validity, by the employment of exploratory factor analysis, in parts A, B and J, 3, 7 and 3 factors were formed, respectively; and 62.8%, 64% and 51% of the total variances were explained by the obtained factors in parts A, B and J, respectively. The names of these factors in the three parts were achieved by consideration of the loading factor and medical ethics principles. The subscales of MEAVDQ showed significant reliability. In parts A, B and J, Cronbach’s alpha coefficients were 0.76, 0.72 and 0.68, respectively and for the total questionnaire, it was 0.72. The results of the test–retest were satisfactory for all the items (ICC = 0.60 - 0.95). Conclusions: The present study showed that the 59-item MEAVDQ was a valid and reliable questionnaire for the assessment of women’s attitudes toward medical ethics application in vaginal childbirth. This tool might assist specialists in making a judgment and plan appropriate for women in vaginal delivery management

    Microbiological qualification of air, water and dialysate in a haemodialysis centre; a new focus on Legionella spp.

    Get PDF
    Background and Objectives: The microbiological monitoring of the water used for haemodialysis is important especially for Legionella and non-fermentative bacteria since patients with end stage renal disease (ESRD) are suffering from deteriorated function of immune system. Materials and Methods: A total 50 water and dialysate samples were weekly collected over a period of 10 weeks from 5 sites. Total and faecal coliforms were determined by utilizing the most probable number (MPN) method. For isolation of Legionella, water samples were inoculated on a BCYE medium. DNA extraction was performed and was used to amplify 16S rRNA gene of Legionella species. Airborne bacteria were sampled using a single stage Andersen air sampler. Results: Out of total 50 water samples, 24 samples had bacterial contamination. The highest rate of Legionella contamination was observed in the storage tank (67 cfu/ml). Legionella was not isolated from the dialysate effluent samples. The highest rate of total bacterial count was related to the dialysate effluent and the maximum total count of coliforms was related to the reverse osmosis. The isolated bacteria were Gram-negative bacilli (mostly Pseudomonas isolates), Gram-positive cocci (mostly Micrococcus spp.) and Gram-positive bacilli (mostly Bacillus spp.). Six samples were contaminated with coliforms. No faecal coliform was isolated from the samples. Conclusion: These results indicated that dialysis machine is an important source of contaminations such as Staphylococcus, Pseudomonas and Legionella. Therefore an efficient prevention program is needed to eliminate bacterial contamination of dialysis water system. Moreover, in haemodialysis centres, periodic surveillance programs for microbiological qualification can lead to a better planning for disinfection of haemodialysis water systems. © 2016, Tehran University of Medical Science. All rights reserved

    The effects of phase III cardiac rehabilitation in serum and salivary Hs-CRP and anthropometric measurements in patients with coronary artery disease

    Get PDF
    Aim: Cardiac rehabilitation is a key part in the treatment of coronary artery disease (CAD) by its anti-inflammatory effects. However, the effect of exercise training programs on salivary concentrations of high-sensitivity C-reactive protein (hs-CRP) in patients with coronary artery disease has not been well studied. The objective of this study was to evaluate the effect of phase III cardiac rehabilitation on serum and salivary levels of hs-CRP, in relation to the anthropometric measurements of obesity and the relationship between salivary and serum levels of hs-CRP in CAD male patients. Materials and methods: Forty male volunteers (45-75 years) with CAD participated in 6 to 8 weeks of moderate intensity aerobic exercise training consisting of 45 minutes sessions of treadmill, stationary bicycle and arm ergometer. Anthropometric measurements of obesity, serum level of hs-CRP, stimulated and nonstimulated salivary level of hs-CRP were measured at the beginning, in the middle and at the end of exercise sessions. Results: All anthropometric measurements increased (p < 0.05) following cardiac rehabilitation except waist-hip ratio. Serum hs- CRP level reduced by 36 independent to the anthropometric measurements changes. Stimulated and nonstimulated salivary hs-CRP level decreased 68 and 54, respectively, after 24 sessions of cardiac rehabilitation. Nonstimulated salivary hs-CRP levels correlated to serum levels of hs-CRP at baseline and after 24 sessions (p < 0.05). Conclusion: Phase III cardiac rehabilitation seems to be effective to improve serum and salivary hs-CRP concentrations independent of anthropometric measurements. Clinical significance: Nonstimulated salivary hs-CRP measurement could be a surrogate for blood measurement of hs-CRP during cardiac rehabilitation in male patients with CAD

    Methicillin-resistant staphylococcus epidermidis in Iran: A systematic review and meta-analysis

    Get PDF
    Objective: Methicillin-resistant Staphylococcus epidermidis (MRSE) remains one of the most prevalent drug-resistant bacteria causing health care infections. Limited data are available about how the frequency of MRSE changed in Iran over the past years. The current study aimed at determining the frequency of MRSE in different cities of Iran. Methods: Databases including Web of Sciences, Scopus, Embase, Medline, and Iranian databases were searched to find studies addressing the frequency of MRSE in Iran published from Mar 2006 to Jan 2016. The data were analyzed using comprehensive meta-analysis version 2.2 (Biostat). Of the 139 records identified in the databases, 15 studies met the inclusion criteria. Results: The analyses showed that the frequency of MRSE infections was 73.9 95% confidence interval (95% CI) 61.4-83.4 among culture-positive cases of S. epidermidis in different parts of Iran. The frequency of MRSE was higher in the studies conducted from 2011 to 2015, based on further stratified analyses. Conclusions: The regular surveillance on antimicrobial susceptibility pattern and formulation of definite antibiotic policy may control high rate of MRSE associated infections in Iran. Moreover, rapid and reliable diagnosis of MRSE isolates and regular screening of the personnel and surfaces of hospitals in terms of MRSE are indispensable. © 2018, Archives of Clinical Infectious Diseases

    The global prevalence of Daptomycin, Tigecycline, Quinupristin/Dalfopristin, and Linezolid-resistant Staphylococcus aureus and coagulase-negative staphylococci strains: A systematic review and meta-analysis

    Get PDF
    Objective: Methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-resistant coagulase-negative Staphylococcus (MRCoNS) are among the main causes of nosocomial infections, which have caused major problems in recent years due to continuously increasing spread of various antibiotic resistance features. Apparently, vancomycin is still an effective antibiotic for treatment of infections caused by these bacteria but in recent years, additional resistance phenotypes have led to the accelerated introduction of newer agents such as linezolid, tigecycline, daptomycin, and quinupristin/dalfopristin (Q/D). Due to limited data availability on the global rate of resistance to these antibiotics, in the present study, the resistance rates of S. aureus, Methicillin-resistant S. aureus (MRSA), and CoNS to these antibiotics were collected. Method: Several databases including web of science, EMBASE, and Medline (via PubMed), were searched (September 2018) to identify those studies that address MRSA, and CONS resistance to linezolid, tigecycline, daptomycin, and Q/D around the world. Result: Most studies that reported resistant staphylococci were from the United States, Canada, and the European continent, while African and Asian countries reported the least resistance to these antibiotics. Our results showed that linezolid had the best inhibitory effect on S. aureus. Although resistances to this antibiotic have been reported from different countries, however, due to the high volume of the samples and the low number of resistance, in terms of statistical analyzes, the resistance to this antibiotic is zero. Moreover, linezolid, daptomycin and tigecycline effectively (99.9) inhibit MRSA. Studies have shown that CoNS with 0.3 show the lowest resistance to linezolid and daptomycin, while analyzes introduced tigecycline with 1.6 resistance as the least effective antibiotic for these bacteria. Finally, MRSA and CoNS had a greater resistance to Q/D with 0.7 and 0.6, respectively and due to its significant side effects and drug-drug interactions; it appears that its use is subject to limitations. Conclusion: The present study shows that resistance to new agents is low in staphylococci and these antibiotics can still be used for treatment of staphylococcal infections in the world. © 2020 The Author(s)

    Distribution of the most prevalent spa types among clinical isolates of methicillin-resistant and -susceptible Staphylococcus aureus around the world: A review

    Get PDF
    Background: Staphylococcus aureus, a leading cause of community-acquired and nosocomial infections, remains a major health problem worldwide. Molecular typing methods, such as spa typing, are vital for the control and, when typing can be made more timely, prevention of S. aureus spread around healthcare settings. The current study aims to review the literature to report the most common clinical spa types around the world, which is important for epidemiological surveys and nosocomial infection control policies. Methods: A search via PubMed, Google Scholar, Web of Science, Embase, the Cochrane library, and Scopus was conducted for original articles reporting the most prevalent spa types among S. aureus isolates. The search terms were "Staphylococcus aureus, spa typing." Results: The most prevalent spa types were t032, t008 and t002 in Europe; t037 and t002 in Asia; t008, t002, and t242 in America; t037, t084, and t064 in Africa; and t020 in Australia. In Europe, all the isolates related to spa type t032 were MRSA. In addition, spa type t037 in Africa and t037and t437 in Australia also consisted exclusively of MRSA isolates. Given the fact that more than 95 of the papers we studied originated in the past decade there was no option to study the dynamics of regional clone emergence. Conclusion: This review documents the presence of the most prevalent spa types in countries, continents and worldwide and shows big local differences in clonal distribution. © 2018 Asadollahi, Farahani, Mirzaii, Khoramrooz, van Belkum, Asadollahi, Dadashi and Darban-Sarokhalil
    corecore