22 research outputs found

    Establishing a pre-clinical growing animal model to test a tissue engineered valved pulmonary conduit

    Get PDF
    Background: Many valvular pathologies of the heart may be only sufficiently treated by replacement of the valve if a reconstruction is not feasible. However, structural deterioration, thrombosis with thromboembolic events and infective endocarditis are commonly encountered complications over time and often demand a re-operation. In congenital heart disease the lack of small diameter valves with the potential to grow poses additional challenges and limits treatment options to homo- or xenograft implants. Methods: In this study, a chronic sheep model (24 months follow-up), a self-constructed valved conduit was created out of a tissue engineered (TE) patch (CorMatrix® Cardiovascular, Inc, USA) and implanted in orthotopic right ventricular (RV)-pulmonary artery (PA) position. Thereafter, the sheep were regularly monitored by clinical, laboratory and echocardiographic examinations to evaluate cardiac function and the implanted RV-PA-conduit. Discussion: Here, we summarize the study protocol and our experiences during the perioperative phase and the follow up period and explain how we constructed a valved conduit out of a commercially available TE patch. Trial registration: License number: ZH 284/14

    Animals in cardiovascular research

    Full text link

    Quantitative myocardial first-pass cardiovascular magnetic resonance perfusion imaging using hyperpolarized [1-13C] pyruvate

    Full text link
    BACKGROUND: The feasibility of absolute myocardial blood flow quantification and suitability of hyperpolarized [1-13C] pyruvate as contrast agent for first-pass cardiovascular magnetic resonance (CMR) perfusion measurements are investigated with simulations and demonstrated in vivo in a swine model. METHODS: A versatile simulation framework for hyperpolarized CMR subject to physical, physiological and technical constraints was developed and applied to investigate experimental conditions for accurate perfusion CMR with hyperpolarized [1-13C] pyruvate. Absolute and semi-quantitative perfusion indices were analyzed with respect to experimental parameter variations and different signal-to-noise ratio (SNR) levels. Absolute myocardial blood flow quantification was implemented with an iterative deconvolution approach based on Fermi functions. To demonstrate in vivo feasibility, velocity-selective excitation with an echo-planar imaging readout was used to acquire dynamic myocardial stress perfusion images in four healthy swine. Arterial input functions were extracted from an additional image slice with conventional excitation that was acquired within the same heartbeat. RESULTS: Simulations suggest that obtainable SNR and B0 inhomogeneity in vivo are sufficient for the determination of absolute and semi-quantitative perfusion with ≤25% error. It is shown that for expected metabolic conversion rates, metabolic conversion of pyruvate can be neglected over the short duration of acquisition in first-pass perfusion CMR. In vivo measurements suggest that absolute myocardial blood flow quantification using hyperpolarized [1-13C] pyruvate is feasible with an intra-myocardial variability comparable to semi-quantitative perfusion indices. CONCLUSION: The feasibility of quantitative hyperpolarized first-pass perfusion CMR using [1-13C] pyruvate has been investigated in simulations and demonstrated in swine. Using an approved and metabolically active compound is envisioned to increase the value of hyperpolarized perfusion CMR in patients

    Hyperpolarized C-13 urea myocardial first-pass perfusion imaging using velocity-selective excitation

    No full text
    Background A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized 13C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced 1H measurements in-vivo. Methods The proposed excitation with an echo-planar imaging readout was implemented on a clinical CMR system. Dynamic myocardial stress perfusion images were acquired in six healthy pigs after bolus injection of hyperpolarized 13C urea with the velocity-selective vs. conventional excitation, as well as standard 1H gadolinium-enhanced images. Signal-to-noise, contrast-to-noise (CNR) and homogeneity of semi-quantitative perfusion measures were compared between methods based on first-pass signal-intensity time curves extracted from a mid-ventricular slice. Diagnostic feasibility is demonstrated in a case of septal infarction. Results Velocity-selective excitation provides over three-fold reduction in blood pool signal with a two-fold increase in myocardial CNR. Extracted first-pass perfusion curves reveal a significantly reduced variability of semi-quantitative first-pass perfusion measures (12–20%) for velocity-selective excitation compared to conventional excitation (28–93%), comparable to that of reference 1H gadolinium data (9–15%). Overall image quality appears comparable between the velocity-selective hyperpolarized and gadolinium-enhanced imaging. Conclusion The feasibility of hyperpolarized 13C first-pass perfusion CMR has been demonstrated in swine. Comparison with reference 1H gadolinium data revealed sufficient data quality and indicates the potential of hyperpolarized perfusion imaging for human applications.ISSN:1097-6647ISSN:1532-429

    Development of a Novel Human Cell-Derived Tissue-Engineered Heart Valve for Transcatheter Aortic Valve Replacement: an In Vitro and In Vivo Feasibility Study

    Full text link
    Transcatheter aortic valve replacement (TAVR) is being extended to younger patients. However, TAVR-compatible bioprostheses are based on xenogeneic materials with limited durability. Off-the-shelf tissue-engineered heart valves (TEHVs) with remodeling capacity may overcome the shortcomings of current TAVR devices. Here, we develop for the first time a TEHV for TAVR, based on human cell-derived extracellular matrix and integrated into a state-of-the-art stent for TAVR. The TEHVs, characterized by a dense acellular collagenous matrix, demonstrated in vitro functionality under aortic pressure conditions (n = 4). Next, transapical TAVR feasibility and in vivo TEHV functionality were assessed in acute studies (n = 5) in sheep. The valves successfully coped with the aortic environment, showing normal leaflet motion, free coronary flow, and absence of stenosis or paravalvular leak. At explantation, TEHVs presented full structural integrity and initial cell infiltration. Its long-term performance proven, such TEHV could fulfill the need for next-generation lifelong TAVR prostheses

    Differential leaflet remodeling of bone marrow cell pre-seeded versus nonseeded bioresorbable transcatheter pulmonary valve replacements

    No full text
    This study showed that bone marrow mononuclear cell pre-seeding had detrimental effects on functionality and in situ remodeling of bioresorbable bisurea-modified polycarbonate (PC-BU)-based tissue-engineered heart valves (TEHVs) used as transcatheter pulmonary valve replacement in sheep. We also showed heterogeneous valve and leaflet remodeling, which affects PC-BU TEHV safety, challenging their potential for clinical translation. We suggest that bone marrow mononuclear cell pre-seeding should not be used in combination with PC-BU TEHVs. A better understanding of cell–scaffold interaction and in situ remodeling processes is needed to improve transcatheter valve design and polymer absorption rates for a safe and clinically relevant translation of this approach

    Differential Leaflet Remodeling of Bone Marrow Cell Pre-Seeded Versus Nonseeded Bioresorbable Transcatheter Pulmonary Valve Replacements

    No full text
    This study showed that bone marrow mononuclear cell pre-seeding had detrimental effects on functionality and in situ remodeling of bioresorbable bisurea-modified polycarbonate (PC-BU)-based tissue-engineered heart valves (TEHVs) used as transcatheter pulmonary valve replacement in sheep. We also showed heterogeneous valve and leaflet remodeling, which affects PC-BU TEHV safety, challenging their potential for clinical translation. We suggest that bone marrow mononuclear cell pre-seeding should not be used in combination with PC-BU TEHVs. A better understanding of cell–scaffold interaction and in situ remodeling processes is needed to improve transcatheter valve design and polymer absorption rates for a safe and clinically relevant translation of this approach
    corecore