84 research outputs found

    Trimethylamine, a gut bacteria metabolite and air pollutant, increases blood pressure and markers of kidney damage including proteinuria and KIM-1 in rats

    Get PDF
    BACKGROUND: Trimethylamine oxide (TMAO) is a biomarker in cardiovascular and renal diseases. TMAO originates from the oxidation of trimethylamine (TMA), a product of gut microbiota and manufacturing industries-derived pollutant, by flavin monooxygenases (FMOs). The effect of chronic exposure to TMA on cardiovascular and renal systems is undetermined. METHODS: Metabolic, hemodynamic, echocardiographic, biochemical and histopathological evaluations were performed in 12-week-old male SPRD rats receiving water (controls) or TMA (200 or 500 µM/day) in water for 18 weeks. TMA and TMAO levels, the expression of FMOs and renin-angiotensin system (RAS) genes were evaluated in various tissues. RESULTS: In comparison to controls, rats receiving high dose of TMA had significantly increased arterial systolic blood pressure (126.3 ± 11.4 vs 151.2 ± 19.9 mmHg; P = 0.01), urine protein to creatinine ratio (1.6 (1.5; 2.8) vs 3.4 (3.3; 4.2); P = 0.01), urine KIM-1 levels (2338.3 ± 732.0 vs. 3519.0 ± 953.0 pg/mL; P = 0.01), and hypertrophy of the tunica media of arteries and arterioles (36.61 ± 0.15 vs 45.05 ± 2.90 µm, P = 0.001 and 18.44 ± 0.62 vs 23.79 ± 2.60 µm, P = 0.006; respectively). Mild degeneration of renal bodies with glomerulosclerosis was also observed. There was no significant difference between the three groups in body weight, water-electrolyte balance, echocardiographic parameters and RAS expression. TMA groups had marginally increased 24 h TMA urine excretion, whereas serum levels and 24 h TMAO urine excretion were increased up to 24-fold, and significantly increased TMAO levels in the liver, kidneys and heart. TMA groups had lower FMOs expression in the kidneys. CONCLUSIONS: Chronic exposure to TMA increases blood pressure and increases markers of kidney damage, including proteinuria and KIM-1. TMA is rapidly oxidized to TMAO in rats, which may limit the toxic effects of TMA on other organs. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12967-022-03687-y

    (Photo)physical properties of new molecular glasses end-capped with thiophene rings composed of diimide and imine units

    Get PDF
    New symmetrical arylene bisimide derivatives formed by using electron-donating-electron-accepting systems were synthesized. They consist of a phthalic diimide or naphthalenediimide core and imine linkages and are end-capped with thiophene, bithiophene, and (ethylenedioxy)thiophene units. Moreover, polymers were obtained from a new diamine, N,N′-bis(5- aminonaphthalenyl)naphthalene-1,4,5,8-dicarboximide and 2,5- thiophenedicarboxaldehyde or 2,2′-bithiophene-5,5′-dicarboxaldehyde. The prepared azomethine diimides exhibited glass-forming properties. The obtained compounds emitted blue light with the emission maximum at 470 nm. The value of the absorption coefficient was determined as a function of the photon energy using spectroscopic ellipsometry. All compounds are electrochemically active and undergo reversible electrochemical reduction and irreversible oxidation processes as was found in cyclic voltammetry and differential pulse voltammetry (DPV) studies. They exhibited a low electrochemically (DPV) calculated energy band gap (Eg) from 1.14 to 1.70 eV. The highest occupied molecular orbital and lowest unoccupied molecular orbital levels and Eg were additionally calculated theoretically by density functional theory at the B3LYP/6-31G(d,p) level. The photovoltaic properties of two model compounds as the active layer in organic solar cells in the configuration indium tin oxide/poly(3,4-(ethylenedioxy)thiophene):poly(styrenesulfonate)/active layer/Al under an illumination of 1.3 mW/cm2 were studied. The device comprising poly(3-hexylthiophene) with the compound end-capped with bithiophene rings showed the highest value of Voc (above 1 V). The conversion efficiency of the fabricated solar cell was in the range of 0.69-0.90%

    Antimicrobial consumption and resistance in adult hospital inpatients in 53 countries:results of an internet-based global point prevalence survey

    Get PDF
    Summary: Background: The Global Point Prevalence Survey (Global-PPS) established an international network of hospitals to measure antimicrobial prescribing and resistance worldwide. We aimed to assess antimicrobial prescribing and resistance in hospital inpatients. Methods: We used a standardised surveillance method to collect detailed data about antimicrobial prescribing and resistance from hospitals worldwide, which were grouped by UN region. The internet-based survey included all inpatients (adults, children, and neonates) receiving an antimicrobial who were on the ward at 0800 h on one specific day between January and September, 2015. Hospitals were classified as primary, secondary, tertiary (including infectious diseases hospitals), and paediatric hospitals. Five main ward types were defined: medical wards, surgical wards, intensive-care units, haematology oncology wards, and medical transplantation (bone marrow or solid transplants) wards. Data recorded included patient characteristics, antimicrobials received, diagnosis, therapeutic indication according to predefined lists, and markers of prescribing quality (eg, whether a stop or review date were recorded, and whether local prescribing guidelines existed and were adhered to). We report findings for adult inpatients. Findings: The Global-PPS for 2015 included adult data from 303 hospitals in 53 countries, including eight lower-middle-income and 17 upper-middle-income countries. 86 776 inpatients were admitted to 3315 adult wards, of whom 29 891 (34·4%) received at least one antimicrobial. 41 213 antimicrobial prescriptions were issued, of which 36 792 (89·3%) were antibacterial agents for systemic use. The top three antibiotics prescribed worldwide were penicillins with β-lactamase inhibitors, third-generation cephalosporins, and fluoroquinolones. Carbapenems were most frequently prescribed in Latin America and west and central Asia. Of patients who received at least one antimicrobial, 5926 (19·8%) received a targeted antibacterial treatment for systemic use, and 1769 (5·9%) received a treatment targeting at least one multidrug-resistant organism. The frequency of health-care-associated infections was highest in Latin America (1518 [11·9%]) and east and south Asia (5363 [10·1%]). Overall, the reason for treatment was recorded in 31 694 (76·9%) of antimicrobial prescriptions, and a stop or review date in 15 778 (38·3%). Local antibiotic guidelines were missing for 7050 (19·2%) of the 36 792 antibiotic prescriptions, and guideline compliance was 77·4%. Interpretation: The Global-PPS showed that worldwide surveillance can be accomplished with voluntary participation. It provided quantifiable measures to assess and compare the quantity and quality of antibiotic prescribing and resistance in hospital patients worldwide. These data will help to improve the quality of antibiotic prescribing through education and practice changes, particularly in low-income and middle-income countries that have no tools to monitor antibiotic prescribing in hospitals. Funding: bioMérieux

    Use of the WHO Access, Watch, and Reserve classification to define patterns of hospital antibiotic use (AWaRe): an analysis of paediatric survey data from 56 countries

    Get PDF
    BACKGROUND: Improving the quality of hospital antibiotic use is a major goal of WHO's global action plan to combat antimicrobial resistance. The WHO Essential Medicines List Access, Watch, and Reserve (AWaRe) classification could facilitate simple stewardship interventions that are widely applicable globally. We aimed to present data on patterns of paediatric AWaRe antibiotic use that could be used for local and national stewardship interventions. METHODS: 1-day point prevalence survey antibiotic prescription data were combined from two independent global networks: the Global Antimicrobial Resistance, Prescribing, and Efficacy in Neonates and Children and the Global Point Prevalence Survey on Antimicrobial Consumption and Resistance networks. We included hospital inpatients aged younger than 19 years receiving at least one antibiotic on the day of the survey. The WHO AWaRe classification was used to describe overall antibiotic use as assessed by the variation between use of Access, Watch, and Reserve antibiotics, for neonates and children and for the commonest clinical indications. FINDINGS: Of the 23 572 patients included from 56 countries, 18 305 were children (77·7%) and 5267 were neonates (22·3%). Access antibiotic use in children ranged from 7·8% (China) to 61·2% (Slovenia) of all antibiotic prescriptions. The use of Watch antibiotics in children was highest in Iran (77·3%) and lowest in Finland (23·0%). In neonates, Access antibiotic use was highest in Singapore (100·0%) and lowest in China (24·2%). Reserve antibiotic use was low in all countries. Major differences in clinical syndrome-specific patterns of AWaRe antibiotic use in lower respiratory tract infection and neonatal sepsis were observed between WHO regions and countries. INTERPRETATION: There is substantial global variation in the proportion of AWaRe antibiotics used in hospitalised neonates and children. The AWaRe classification could potentially be used as a simple traffic light metric of appropriate antibiotic use. Future efforts should focus on developing and evaluating paediatric antibiotic stewardship programmes on the basis of the AWaRe index. FUNDING: GARPEC was funded by the PENTA Foundation. GARPEC-China data collection was funded by the Sanming Project of Medicine in Shenzhen (SZSM2015120330). bioMérieux provided unrestricted funding support for the Global-PPS

    Magnetoelektryczne silniki prądu stałego z proszkowymi obwodami magnetycznymi

    No full text
    Producers of electric machines permanently struggle to offer machines with better performance and operational parameters with simultaneous reduction of manufacturing costs. In case of transducers with magnetic circuits, application of powder magnetic materials offers wide opportunities for cost-effectiveness production and good operational parameters. The studies reported herein deal with a commutator-type DC motor where a conventional magnetic circuit was replaced with a one that was made by compaction of magnetic powders with an appropriate binder. The paper shows the measurements of DC motors with prepared powder magnetic circuits and traditional magnetic circuits.Rozwój nowych generacji materiałów magnetycznych pozwala na rozwój nowych urządzeń z obwodami magnetycznymi. Opracowanie technologii wytwarzania proszkowych materiałów magnetycznych umożliwia zmianę konstrukcji i technologii wytwarzania urządzeń z obwodami magnetycznymi. Ostatnie lata przyniosły rozwój proszkowych materiałów magnetycznie miękkich i magnetycznie twardych. W obecnie produkowanych maszynach elektrycznych, magnetycznie miękka część obwodu magnetycznego wykonywana jest z blach elektrotechnicznych, zaś jako źródło wzbudzenia stosowane są najczęściej magnesy ferrytowe. Blachy elektrotechniczne charakteryzują się bardzo dobrymi właściwościami magnetycznymi, ale ich wadą jest wysoka cena. W przypadku magnesów ferrytowych ich zaletą jest niska cena, ale wadą słabe właściwości magnetyczne. Proszkowe materiały magnetyczne mogą umożliwić poprawę parametrów eksploatacyjnych urządzeń z obwodami magnetycznymi a jednocześnie pozwolić na obniżenie kosztów ich produkcji. Celem prowadzonych badań jest sprawdzenie możliwości stosowania proszkowych obwodów magnetycznych w produkowanych silnikach elektrycznych prądu stałego z magnesami trwałymi. Przeprowadzono próby zastąpienia tradycyjnego obwodu magnetycznego proszkowym obwodem magnetycznym w silniku prądu stałego typu PRMO 30-5D produkowanym przez fabrykę Mikroma S. A. Badania symulacyjne pokazały, że możliwe jest zastąpienie produkowanego obwodu magnetycznego tego silnika proszkowym obwodem magnetycznym. Obwód magnetyczny wirnika został wykonany z proszku żelaza spajanego tworzywem - dielektromagnetyku, zaś magnesy wzbudzenia z proszku z szybko chłodzonej taśmy Nd-Fe-B spajanej tworzywem - dielektromagnesu (tab. 1). Wykonano modele silników z proszkowymi obwodami magnetycznymi (tab. 2). Przeprowadzono badania wykonanych modeli silników. Na rysunku 1. przedstawiono charakterystyki ruchowe silników. W tabelach 3-5 pokazano wybrane parametry badanych silników, natomiast charakterystyki sterowania na rysunku 2. Przeprowadzone badania pokazały, że stosowanie proszkowych obwodów magnetycznych w maszynach prądu stałego jest możliwe i celowe. Stosowanie tego typu obwodów magnetycznych pozwala na sterowanie parametrami eksploatacyjnymi silników

    Research on Isomer Decay with the NEPTUNE Spectrometer

    No full text
    A new spectrometer has been built at the EC-JRC IRMM to investigate isomer decay in the millisecond range and activation cross sections of isotopes, where isomeric states exist and are populated. The spectrometer is equipped with high-resolution gamma-ray detectors and an ionisation chamber for the measurement of charged particles, e.g., fission fragments. NEPTUNE provides pulsed quasi mono-energetic neutrons at pulse repetition frequencies up to 5 kHz and tuneable neutron pulse widths ranging from 10 µs into the ms-region. For this purpose a beam chopper based on a parallel-plate capacitor has been integrated into the accelerator beam line in order to deflect the charged-particle beam onto a tantalum beam dump. First research has been performed with the NEPTUNE spectrometer dedicated to the shape isomer search in the odd-A uranium isotopes 235U, 237U and 239U. In further experiments the population of long-lived spin isomers was investigated.JRC.D.5-Neutron physic

    NEPTUNE - The New Isomer Spectrometer at IRMM

    No full text
    A new spectrometer has been built at the EC-JRC IRMM to investigate isomer decay in the millisecond range and activation cross-sections of isotopes, where isomeric states exist and are populated. The spectrometer uses high-resolution ¿-ray detectors and an ionisation chamber for the measurement of charged particles, e. g. fission fragments. NEPTUNE provides pulsed quasi mono-energetic neutrons at pulse repetition frequencies up to 5 kHz and tuneable neutron pulse widths. For this purpose a beam chopper based on a parallel-plate condenser has been integrated into the accelerator beam-line in order to deflect the charged-particle beam onto a tantalum beam dump. An instrument status report is given together with results from first experiments dedicated to the search for shape isomers in 235,239U performed with the NEPTUNE isomer spectrometer.JRC.D.5-Neutron physic

    Research on isomer decay with the NEPTUNE spectrometer

    No full text
    A new spectrometer has been built at the EC-JRC IRMM to investigate isomer decay in the millisecond range and activation cross sections of isotopes, where isomeric states exist and are populated. The spectrometer is equipped with high-resolution gamma-ray detectors and an ionisation chamber for the measurement of charged particles, e.g., fission fragments. NEPTUNE provides pulsed quasi mono-energetic neutrons at pulse repetition frequencies up to 5 kHz and tuneable neutron pulse widths ranging from 10 µs into the ms-region. For this purpose a beam chopper based on a parallel-plate capacitor has been integrated into the accelerator beam line in order to deflect the charged-particle beam onto a tantalum beam dump. First research has been performed with the NEPTUNE spectrometer dedicated to the shape isomer search in the odd-A uranium isotopes 235U, 237U and 239U. In further experiments the population of long-lived spin isomers was investigated
    corecore