    Control of Whole Heart Geometry by Intramyocardial Mechano-Feedback: A Model Study

    Get PDF
    Geometry of the heart adapts to mechanical load, imposed by pressures and volumes of the cavities. We regarded preservation of cardiac geometry as a homeostatic control system. The control loop was simulated by a chain of models, starting with geometry of the cardiac walls, sequentially simulating circulation hemodynamics, myofiber stress and strain in the walls, transfer of mechano-sensed signals to structural changes of the myocardium, and finalized by calculation of resulting changes in cardiac wall geometry. Instead of modeling detailed mechano-transductive pathways and their interconnections, we used principles of control theory to find optimal transfer functions, representing the overall biological responses to mechanical signals. As biological responses we regarded tissue mass, extent of contractile myocyte structure and extent of the extra-cellular matrix. Mechano-structural stimulus-response characteristics were considered to be the same for atrial and ventricular tissue. Simulation of adaptation to self-generated hemodynamic load rendered physiologic geometry of all cardiac cavities automatically. Adaptation of geometry to chronic hypertension and volume load appeared also physiologic. Different combinations of mechano-sensors satisfied the condition that control of geometry is stable. Thus, we expect that for various species, evolution may have selected different solutions for mechano-adaptation

    Electro-energetics of Biventricular, Septal and Conduction System Pacing

    Get PDF
    Abnormal electrical activation of the ventricles creates abnormalities in cardiac mechanics. Local contraction patterns, as reflected by strain, are not only out of phase, but also show opposing length changes in early and late activated regions. Consequently, the efficiency of cardiac pump function (the amount of stroke work generated by a unit of oxygen consumed), is approximately 30% lower in dyssynchronous than in synchronous hearts. Maintaining good cardiac efficiency appears important for long-term outcomes. Biventricular, left ventricular septal, His bundle and left bundle branch pacing may minimise the amount of pacing-induced dyssynchrony and efficiency loss when compared to conventional right ventricular pacing. An extensive animal study indicates maintenance of mechanical synchrony and efficiency during left ventricular septal pacing and data from a few clinical studies support the idea that this is also the case for left bundle branch pacing and His bundle pacing. This review discusses electro-mechanics and mechano-energetics under the various paced conditions and provides suggestions for future research

    Cardiac resynchronization therapy: mechanisms of action and scope for further improvement in cardiac function.

    Get PDF
    Aims: Cardiac resynchronization therapy (CRT) may exert its beneficial haemodynamic effect by improving ventricular synchrony and improving atrioventricular (AV) timing. The aim of this study was to establish the relative importance of the mechanisms through which CRT improves cardiac function and explore the potential for additional improvements with improved ventricular resynchronization. Methods and Results: We performed simulations using the CircAdapt haemodynamic model and performed haemodynamic measurements while adjusting AV delay, at low and high heart rates, in 87 patients with CRT devices. We assessed QRS duration, presence of fusion, and haemodynamic response. The simulations suggest that intrinsic PR interval and the magnitude of reduction in ventricular activation determine the relative importance of the mechanisms of benefit. For example, if PR interval is 201 ms and LV activation time is reduced by 25 ms (typical for current CRT methods), then AV delay optimization is responsible for 69% of overall improvement. Reducing LV activation time by an additional 25 ms produced an additional 2.6 mmHg increase in blood pressure (30% of effect size observed with current CRT). In the clinical population, ventricular fusion significantly shortened QRS duration (Δ-27 ± 23 ms, P < 0.001) and improved systolic blood pressure (mean 2.5 mmHg increase). Ventricular fusion was present in 69% of patients, yet in 40% of patients with fusion, shortening AV delay (to a delay where fusion was not present) produced the optimal haemodynamic response. Conclusions: Improving LV preloading by shortening AV delay is an important mechanism through which cardiac function is improved with CRT. There is substantial scope for further improvement if methods for delivering more efficient ventricular resynchronization can be developed. Clinical Trial Registration: Our clinical data were obtained from a subpopulation of the British Randomised Controlled Trial of AV and VV Optimisation (BRAVO), which is a registered clinical trial with unique identifier: NCT01258829, https://clinicaltrials.gov

    Virtual pacing of a patient's digital twin to predict left ventricular reverse remodelling after cardiac resynchronization therapy

    Get PDF
    Aims Identifying heart failure (HF) patients who will benefit from cardiac resynchronization therapy (CRT) remains challenging. We evaluated whether virtual pacing in a digital twin (DT) of the patient’s heart could be used to predict the degree of left ventricular (LV) reverse remodelling post-CRT. Methods Forty-five HF patients with wide QRS complex (≥130 ms) and reduced LV ejection fraction (≤35%) receiving CRT were and results retrospectively enrolled. Echocardiography was performed before (baseline) and 6 months after CRT implantation to obtain LV volumes and 18-segment longitudinal strain. A previously developed algorithm was used to generate 45 DTs by personalizing the CircAdapt model to each patient’s baseline measurements. From each DT, baseline septal-to-lateral myocardial work difference (MWLW-S,DT) and maximum rate of LV systolic pressure rise (dP/dtmax,DT) were derived. Biventricular pacing was then simulated using patient-specific atrioventricular delay and lead location. Virtual pacing–induced changes ΔMWLW-S,DT and ΔdP/dtmax,DT were correlated with real-world LV end-systolic volume change at 6-month follow-up (ΔLVESV). The DT’s baseline MWLW-S,DT and virtual pacing–induced ΔMWLW-S,DT were both significantly associated with the real patient’s reverse remodelling ΔLVESV (r = −0.60, P < 0.001 and r = 0.62, P < 0.001, respectively), while correlation between ΔdP/dtmax,DT and ΔLVESV was considerably weaker (r = −0.34, P = 0.02). Conclusion Our results suggest that the reduction of septal-to-lateral work imbalance by virtual pacing in the DT can predict real-world post-CRT LV reverse remodelling. This DT approach could prove to be an additional tool in selecting HF patients for CRT and has the potential to provide valuable insights in optimization of CRT delivery
    • …