136 research outputs found

    Adsorption and two-body recombination of atomic hydrogen on 3^3He-4^4He mixture films

    Full text link
    We present the first systematic measurement of the binding energy EaE_a of hydrogen atoms to the surface of saturated 3^3He-4^4He mixture films. EaE_a is found to decrease almost linearly from 1.14(1) K down to 0.39(1) K, when the population of the ground surface state of 3^3He grows from zero to 6×10146\times10^{14} cm2^{-2}, yielding the value 1.2(1)×10151.2(1)\times 10^{-15} K cm2^2 for the mean-field parameter of H-3^3He interaction in 2D. The experiments were carried out with overall 3^3He concentrations ranging from 0.1 ppm to 5 % as well as with commercial and isotopically purified 4^4He at temperatures 70...400 mK. Measuring by ESR the rate constants KaaK_{aa} and KabK_{ab} for second-order recombination of hydrogen atoms in hyperfine states aa and bb we find the ratio Kab/KaaK_{ab}/K_{aa} to be independent of the 3^3He content and to grow with temperature.Comment: 4 pages, 4 figures, all zipped in a sigle file. Submitted to Phys. Rev. Let

    Determinant Structure of the Rational Solutions for the Painlev\'e IV Equation

    Full text link
    Rational solutions for the Painlev\'e IV equation are investigated by Hirota bilinear formalism. It is shown that the solutions in one hierarchy are expressed by 3-reduced Schur functions, and those in another two hierarchies by Casorati determinant of the Hermite polynomials, or by special case of the Schur polynomials.Comment: 19 pages, Latex, using theorem.st

    METROLOGICAL SUPPORT OF DOSIMETRY GAMMA-RAY WITH ENERGY TO 10 MEV FOR RADIATION PROTECTION DEVICES

    Get PDF
    The field of high-energy gamma-ray for the calibration of radiation protection devices can be obtained by capturing thermal neutrons from titanium target (to 7 MeV) and nickel target (to 10 MeV). The aim of this work was to determine the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility to provide dosimetry up to 10 MeV.We have chosen energy intervals in which we can calibrate dosimetry devices taking into account the accompanying generation of gamma-ray neutrons by the fast neutron source 238PuBe, the capture radiation of collimator materials and capture radiation from targets.We measured air kerma rate with the aid of the reference AT5350 dosimeter with the ionization chamber TM32002. Using the Monte-Carlo simulation, we obtained the energy distribution of the air kerma rate for targets. We determined the geometric dimensions of the uniform field and the interval of operating distances of the facility.We investigated the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility for dosimetric radiation protection devices. We showed that in such fields it is possible to calibrate dosimetry devices in the extended energy range up to 10 MeV

    Влияние полноты реализации программы ускоренного выздоровления пациентов, перенесших резекцию ободочной кишки по поводу рака, на эффективность лечения

    Get PDF
    Objective: to assess ERP implementation results in patients with colon cancer and to reveal correlation between compliance of ERP protocol and efficacy of perioperative care.Materials and methods. 124 patients were included in the study. Main group consisted of 62 patients with ERP, others were controls. ERP compliance was assessed using original formula which considers number of accomplished elements of the Protocol and quality of performance of each element.Results. No significant difference between the groups in morbidity was obtained (1.6 % in main group vs 9.8 % controls; р = 0.06). Minor dependence in self-care was obtained in 90.5 % at third post-op day in main group vs 58.0 % in controls (p < 0.0001). Postoperative hospital stay was lower in main group (4.7 ± 0.1 vs 9.0 ± 0.6 days; p < 0.0001). Total hospital stay was lower in main group as well (7.2 ± 0.1 vs 14.1 ± 0.7 days; р < 0.0001). No mortality and readmissions occurred. ERP compliance rate was 80.0 % (56.9–93.3 %). Рostoperative hospital stay in patients with high protocol compliance (≥ 80 %) was significantly shorter then in patients with low protocol compliance (< 80 %): 4.3 ± 0.2 vs 5.1 ± 0.2; р = 0,005).Conclusion. ERP is effective and safe method of postoperative care in patients after colon resection and the effectiveness of the treatment correlates with protocol compliance rate resulted in shorter hospital stay.Целью работы стала оценка непосредственных результатов применения программы ускоренного выздоровления (ПУВ) пациентов, подвергшихся операциям на ободочной кишке, и изучение влияния полноты ее реализации на эффективность лечения.Материалы и методы. В исследование включены 124 пациента. Первую (основную) группу составили 63 больных, в отношении которых которых была применена ПУВ. Пациенты 2-й (контрольной) группы (n = 61) получали стандартное лечение. Для подсчета процента реализации ПУВ нами разработана формула, учитывающая не только количественную реализацию элементов программы, но и качество выполнения каждого из заявленных элементов.Результаты. Частота послеоперационных осложнений в группах и подгруппах достоверно не отличалась (1,6 % (n = 1) – в основной и 9,8 % (n = 6) – в контрольной; р = 0,056). Количество послеоперационных койко-дней ниже в основной группе и составила 4,7 ± 0,1 по сравнению с 9,0 ± 0,6 в контрольной (р < 0,0001). Достоверно ниже было и число общих койко-дней в основной группе (7,2 ± 0,1 против 14,1 ± 0,7 в контрольной (р < 0,0001)). Случаев повторной госпитализации и летальности не отмечено. Доля реализации ПУВ в нашей клинике составила от 56,9 до 93,3 %, медиана – 80 %. Число послеоперационных дней у пациентов с реализацией программы на 80 % и более был достоверно ниже, чем у пациентов с реализацией ПУВ < 80 %: 4,3 ± 0,2 против 5,1 ± 0,2, (р < 0,0001).Заключение. Предложенная ПУВ является эффективным и безопасным методом ведения пациентов, подлежащих хирургическому лечению по поводу рака ободочной кишки. Эффективность лечения, ассоциированная с укорочением сроков пребывания в стационаре, коррелирует с процентом реализации ПУВ

    The Hamiltonian Structure of the Second Painleve Hierarchy

    Full text link
    In this paper we study the Hamiltonian structure of the second Painleve hierarchy, an infinite sequence of nonlinear ordinary differential equations containing PII as its simplest equation. The n-th element of the hierarchy is a non linear ODE of order 2n in the independent variable zz depending on n parameters denoted by t1,...,tn1{t}_1,...,{t}_{n-1} and αn\alpha_n. We introduce new canonical coordinates and obtain Hamiltonians for the zz and t1,...,tn1t_1,...,t_{n-1} evolutions. We give explicit formulae for these Hamiltonians showing that they are polynomials in our canonical coordinates

    Rational Solutions of the Painleve' VI Equation

    Full text link
    In this paper, we classify all values of the parameters α\alpha, β\beta, γ\gamma and δ\delta of the Painlev\'e VI equation such that there are rational solutions. We give a formula for them up to the birational canonical transformations and the symmetries of the Painlev\'e VI equation.Comment: 13 pages, 1 Postscript figure Typos fixe

    Internal scheme of the body assessment in an experiment with environmental uncertainty

    Get PDF
    The aim of the work was to analyze the influence of various environmental factors forming environmental uncertainty on the nature of the transformation of the "internal scheme of the body". Materials and methods. For the study, a group of healthy volunteers (n = 90) was selected. The results in this paper are median, 75 and 25 percentiles (Me [UQ / LQ]). The study was conducted in several stages. At the first stage, the criteria for excluding potential participants from the experiment were formed. At the second stage of the study, a video analysis of the main anatomical orientations of the pelvic region in static and dynamic samples was conducted for all participants. Conclusion. In the course of the study, specific patterns of spatial deviations of biomechanical blocks of the pelvic region were established, triggered by changes in the qualitative and quantitative parameters of the external environment. So, in conditions of static equilibrium, coordination is activated with involvement of the anterior and posterior half-rings of the pelvis (frontal biomechanical blocks); in conditions of dynamic equilibrium, diagonal biomechanical blocks of the pelvic region are activated; in conditions of deprivation of visual afferentation, the compensatory reactions of the lateral semirings of the pelvic region (lateral biomechanical blocks) are formed

    ВЛИЯНИЕ РЕКОМБИНАНТНОГО ЛАКТОФЕРРИНА ЧЕЛОВЕКА НА УРОВЕНЬ ПОЛОВЫХ ГОРМОНОВ У САМЦОВ КРЫС РАЗНОГО ВОЗРАСТА

    Get PDF
    A systemic administration of human recombinant lactoferrin to male rats caused an increase in a total testosterone level by 200 % in blood serum, the estradiol concentration decreased significantly by 16.7 %. Upon completion of administration, testosterone was still increased (p < 0.05) for 7 weeks, gradually returning to the control group values without inhibition of endogenous testosterone synthesis. In contrast, the level of estradiol returned to control values. Our study of the rat model of age-related hypogonadism revealed that a systemic per os administration of human recombinant lactoferrin to experimental animals had a significant stimulatory effect on testosterone biosynthesis in 2-yearolds, restoring it to the level of physiological values in young rats. Системное введение рекомбинантного лактоферрина человека молодым (2 мес.) крысам-самцам вызывало увеличение уровня общего тестостерона в сыворотке крови на 200%. После завершения курсового введения содержание тестостерона оставалось повышенным (р < 0,05) в течение семи недель, постепенно возвращаясь до значений контрольной группы без угнетения биосинтеза эндогенного тестостерона. В модели возрастного гипогонадизма системное влияние per os рекомбинантного лактоферрина человека экспериментальным животным оказывало значительное стимулирующее действие на биосинтез тестостерона у 2-летних особей, нормализируя его уровень до физиологических значений молодых крыс.

    ФОРМИРОВАНИЕ ПОЛЯ ЗАХВАТНОГО ГАММА-ИЗЛУЧЕНИЯ ДО 10 МэВ ДЛЯ МЕТРОЛОГИЧЕСКОГО ОБЕСПЕЧЕНИЯ ПРИБОРОВ РАДИАЦИОННОЙ ЗАЩИТЫ

    Get PDF
    Medical, and technological linear particle accelerators, and nuclear reactors are vastly widespread worldwide today. These facility generate fields of secondary gamma radiation with energy to 10 MeV. Therefore, we have a need to calibrate spectrometric and dosimetric ionization measurement instruments for the energies to 10 MeV. The aim of this work is to determine possibility to use thermal neutron collimator of АТ140 Neutron Calibration Facility with 238Pu-Be fast neutron source (IBN-8-6) for this. Below 3 MeV we use a set of point gamma standard spectrometry sources OSGI. We can acquire gamma rays with energies above 3 MeV using radioactive thermal neutron capture on target, i.e. (n, γ)-nuclear reaction. We can use neutron capture gamma-ray from titanium target (to 7 MeV) or nickel target (to 10 MeV) situated in thermal neutron field for calibration. We can use thermal neutron collimator of АТ140 Neutron Calibration Facility with 238Pu-Be fast neutron source (IBN-8-6) for slowing down neutrons from radionuclide fast neutron sources to thermal energies in polyethylene. Thermal neutron collimator forms a beam from radionuclide source with a significant amount of neutrons with thermal energies. We placed Ti and Ni targets in collimator’s canal. We got experimental spectral data on detection unit BDKG-19M NaI(Tl) 63 × 160 mm with nonlinear channel-energy conversion characteristic in range to 10 MeV. For additional filtration we proposed to use polyethylene neutron reflector and lead discs. We experimentally determined that placement of lead discs in collimator in front of the target allows to filter all spectrum while insignificantly weakening target’s emission. Using theoretical and experimental data we proved the ability to calibrate gamma-ray spectrometers in the range to 10 MeV. Развитие и распространение техногенных источников высокоэнергетического вторичного гаммаизлучения приводит к ряду прикладных задач радиационной защиты, в которых спектрометрические и дозиметрические измерительные приборы используются в фотонных полях в диапазоне энергий от 4 до 10 МэВ. Целью данной работы являлась проверка возможности формирования эталонных полей захватного гамма-излучения при помощи источника быстрых нейтронов и мишеней из титана и никеля с энергиями до 10 МэВ. Корректная калибровка предполагает наличие в эталонном спектре излучения одиночных линий с известной энергией. До 3 МэВ задача решается при помощи набора радионуклидных источников ОСГИ. Для формирования эталонного фотонного поля с энергиями до 10 МэВ можно использовать захватное гамма-излучение от мишеней из титана и никеля, находящихся в поле тепловых нейтронов. Поток нейтронов с тепловыми энергиями может быть получен замедлением быстрых нейтронов от радионуклидных источников 238Pu-Be, 252Cf, 241Am-Be. В качестве замедлителя нейтронов обычно используются водородосодержащие материалы (полиэтилен и парафин). Коллиматор тепловых нейтронов установки поверочной нейтронного излучения (УПН-АТ140, УП «АТОМТЕХ») формирует пучок от радионуклидного источника со значительной составляющей нейтронов тепловых энергий. Размещение мишеней в канале коллиматора позволило получить поле гамма-излучения с характерными для материала мишени энергиями. Экспериментальные спектры получены на спектрометрическом блоке детектирования БДКГ-19М NaI(Tl) 63 × 160 мм с нелинейной характеристикой преобразования канал-энергия в диапазоне до 10 МэВ. На спектрах хорошо различимы основные линии захватного излучения от водорода, титана и никеля. В качестве дополнительной фильтрации предложено использовать отражатель нейтронов из полиэтилена и свинцовые диски. Показано, что размещение дисков из свинца в коллиматоре перед мишенью позволяет фильтровать весь спектр, при этом незначительно ослабляя излучение именно от мишени. На основании теоретических и экспериментальных данных подтверждена возможность калибровки спектрометров гамма-излучения в диапазоне до 10 МэВ в поле мгновенного захватного гамма-излучения.
    corecore