848 research outputs found

    Energy and technological refurbishment of the School of Architecture Valle Giulia, Rome

    Get PDF
    Modern architecture built in historical urban contexts represents a demanding issue when its energy efficiency should be improved. Indeed, the strongest efforts have to be made to maintain the architectural identity and its harmony with the surrounding cultural heritage. This study deals with the main building of the School of Architecture Valle Giulia in Rome, designed by Enrico Del Debbio in the 30’s. Further constraints are related to several interventions of airspace expansion starting from 1958 which involved the building starting from 1958. So, preservation would mean highlighting its historic change but, adapting the built environment to the contemporary users’ needs. As above-mentioned, the building belongs to the Valle delle Accademie, within the historic park of Villa Borghese, so that to acquire landscaping values. Those latter ones call for ulterior requirements when any new design process is conceived. The study provides a global renewal of the building accounting for the current low Indoor Environmental Quality in both summer and winter seasons and the lack of suitability to the contemporary University student’s needs. The interaction between building performance and HVAC systems was studied by collecting data and architectural surveys conducted by all the architects who modified the building. This procedure was chosen since thermo-physical investigations are considered destructive due to required perforations to identify the actual wall layers. Moreover, thermographic surveys were carried out to validate the modelled building response. The result of the study is the identification of viable interventions to improve the accessibility and fruition of the building as well as its energy performance. A specific cost-benefit analysis was done to prioritize the design options along with considering the measures needed to preserve all the architectural features and values

    Cell orientation under stretch: Stability of a linear viscoelastic model

    Get PDF
    The sensitivity of cells to alterations in the microenvironment and in particular to external mechanical stimuli is significant in many biological and physiological circumstances. In this regard, experimental assays demonstrated that, when a monolayer of cells cultured on an elastic substrate is subject to an external cyclic stretch with a sufficiently high frequency, a reorganization of actin stress fibres and focal adhesions happens in order to reach a stable equilibrium orientation, characterized by a precise angle between the cell major axis and the largest strain direction. To examine the frequency effect on the orientation dynamics, we propose a linear viscoelastic model that describes the coupled evolution of the cellular stress and the orientation angle. We find that cell orientation oscillates tending to an angle that is predicted by the minimization of a very general orthotropic elastic energy, as confirmed by a bifurcation analysis. Moreover, simulations show that the speed of convergence towards the predicted equilibrium orientation presents a changeover related to the viscous–elastic transition for viscoelastic materials. In particular, when the imposed oscillation period is lower than the characteristic turnover rate of the cytoskeleton and of adhesion molecules such as integrins, reorientation is significantly faster

    Predicted Turbine Heat Transfer for a Range of Test Conditions

    Get PDF
    Comparisons are shown between predictions and experimental data for blade and endwall heat transfer. The comparisons of computational domain parisons are given for both vane and rotor geometries over an extensive range of Reynolds and Mach numbers. Comparisons are made with experimental data from a variety of sources. A number of turbulence models are available for predicting blade surface heat transfer, as well as aerodynamic performance. The results of an investigation to determine the turbulence model which gives the best agreement with experimental data over a wide range of test conditions are presented

    Measurement of Gust Response on a Turbine Cascade

    Get PDF
    The paper presents benchmark experimental data on a gust response of an annular turbine cascade. The experiment was particularly designed to provide data for comparison with the results of a typical linearized gust-response analysis. Reduced frequency, Mach number, and incidence were varied independently. Except for the lowest reduced frequency, the gust velocity distribution was nearly sinusoidal. For the high inlet-velocity series of tests, the cascade was near choking. The mean flow was documented by measuring blade surface pressures and the cascade exit flow. High-response pressure transducers were used to measure the unsteady pressure distribution. Inlet-velocity components and turbulence parameters were measured using hot wire. In addition to the synchronous time-average pressure spectra, typical power spectra are included for several representative conditions

    High Gain Compact Strip and Slot UWB Sinuous Antennas

    Get PDF
    Three ground-backed compact strip-and slot-sinuous antennas are analyzed. Proposed configuration allows for a single lobe, polarization-versatile, high efficiency, and ultrawide band antenna not needing a cumbersome lossy back cavity typical of conventional single-lobe sinuous antennas. Simulations show attained performances as well as tuning possibilities

    Prevalence and pharmacologic management of familial hypercholesterolemia in an unselected contemporary cohort of patients with stable coronary artery disease

    Get PDF
    INTRODUCTION: Familial hypercholesterolemia (FH) is an inherited disorder characterized by elevated plasma levels of low-density lipoprotein cholesterol (LDL-C) associated with premature cardiovascular disease. METHODS: Using the data from the START (STable Coronary Artery Diseases RegisTry) study, a nationwide, prospective survey on patients with stable coronary artery disease (CAD), we described prevalence and lipid lowering strategies commonly employed in these patients. The study population was divided into "definite/probable FH," defined as a Dutch Lipid Clinic Network (DLCN) score ≥6, "possible FH" with DLCN 3-5, and "unlikely FH" in presence of a DLCN <3. RESULTS: Among the 4030 patients with the DLCN score available, 132 (3.3%) were classified as FH (2.3% with definite/probable and 1.0% with possible FH) and 3898 (96.7%) had unlikely FH. Patients with both definite/probable and possible FH were younger compared to patients not presenting FH. Mean on-treatment LDL-C levels were 107.8 ± 41.5, 84.4 ± 40.9, and 85.8 ± 32.3 (P < 0.0001) and a target of ≤70 mg/dL was reached in 10.9%, 30.0%, and 22.0% (P < 0.0001) of patents with definite/probable, possible FH, and unlikely FH, respectively. Statin therapy was prescribed in 85 (92.4%) patients with definite/probable FH, in 38 (95.0%) with possible FH, and in 3621 (92.9%) with unlikely FH (P = 0.86). The association of statin and ezetimibe, in absence of other lipid-lowering therapy, was more frequently used in patients with definite/probable FH compared to patients without FH (31.5% vs 17.5% vs 9.5%; P < 0.0001). CONCLUSIONS: In this large cohort of consecutive patients with stable CAD, FH was highly prevalent and generally undertreated with lipid lowering therapies

    Effect of the refining process on total hydroxytyrosol, tyrosol, and tocopherol contents of olive oil

    Get PDF
    The impact of the olive oil refining process on major antioxidant compound levels was evaluated by means of UHPLC analysis of lampante olive oils collected at different stages of the refining procedure (degumming, chemical and physical flash neutralization, bleaching, and deodorization). For this purpose, the evolution of the tocopherol fraction was investigated by means of the UHPLC-FL method, while the influence of the refining process on the total hydrolyzed phenolic content was assessed by measuring hydroxytyrosol and tyrosol levels after acid hydrolysis of the phenolic extracts. Refining was found to have a marked effect on total hydroxytyrosol and tyrosol contents, as they are completely removed in the early steps of the refining procedure. In contrast, the variation trends of tocopherols are not always clear-cut, and significant decreases in content from 7% to 16% were only revealed during refining in four out of nine samples. In addition, five of the nine refined oils showed final tocopherol concentrations higher than 200 mg/kg, the limit imposed by international standards regarding the content of such compounds in commercial olive oils. This study supports the need for a revision of the International Olive Oil Council (IOC) standard relative to the limit established for tocopherol addition to refined oils to avoid possible legal and economic trade issues
    • …
    corecore