193 research outputs found

    Gravitational Lensing at Millimeter Wavelengths

    Full text link
    With today's millimeter and submillimeter instruments observers use gravitational lensing mostly as a tool to boost the sensitivity when observing distant objects. This is evident through the dominance of gravitationally lensed objects among those detected in CO rotational lines at z>1. It is also evident in the use of lensing magnification by galaxy clusters in order to reach faint submm/mm continuum sources. There are, however, a few cases where millimeter lines have been directly involved in understanding lensing configurations. Future mm/submm instruments, such as the ALMA interferometer, will have both the sensitivity and the angular resolution to allow detailed observations of gravitational lenses. The almost constant sensitivity to dust emission over the redshift range z=1-10 means that the likelihood for strong lensing of dust continuum sources is much higher than for optically selected sources. A large number of new strong lenses are therefore likely to be discovered with ALMA, allowing a direct assessment of cosmological parameters through lens statistics. Combined with an angular resolution <0.1", ALMA will also be efficient for probing the gravitational potential of galaxy clusters, where we will be able to study both the sources and the lenses themselves, free of obscuration and extinction corrections, derive rotation curves for the lenses, their orientation and, thus, greatly constrain lens models.Comment: 69 pages, Review on quasar lensing. Part of a LNP Topical Volume on "Dark matter and gravitational lensing", eds. F. Courbin, D. Minniti. To be published by Springer-Verlag 2002. Paper with full resolution figures can be found at ftp://oden.oso.chalmers.se/pub/tommy/mmviews.ps.g

    Constraining the neutrino emission of gravitationally lensed Flat-Spectrum Radio Quasars with ANTARES data

    Get PDF
    This paper proposes to exploit gravitational lensing effects to improve the sensitivity of neutrino telescopes to the intrinsic neutrino emission of distant blazar populations. This strategy is illustrated with a search for cosmic neutrinos in the direction of four distant and gravitationally lensed Flat-Spectrum Radio Quasars. The magnification factor is estimated for each system assuming a singular isothermal profile for the lens. Based on data collected from 2007 to 2012 by the ANTARES neutrino telescope, the strongest constraint is obtained from the lensed quasar B0218+357, providing a limit on the total neutrino luminosity of this source of 1.08 x 10(46) erg s(-1) This limit is about one order of magnitude lower than those previously obtained in the ANTARES standard point source searches with non-lensed Flat-Spectrum Radio Quasars

    Curvature-bias corrections using a pseudomass method

    Get PDF
    Momentum measurements for very high momentum charged particles, such as muons from electroweak vector boson decays, are particularly susceptible to charge-dependent curvature biases that arise from misalignments of tracking detectors. Low momentum charged particles used in alignment procedures have limited sensitivity to coherent displacements of such detectors, and therefore are unable to fully constrain these misalignments to the precision necessary for studies of electroweak physics. Additional approaches are therefore required to understand and correct for these effects. In this paper the curvature biases present at the LHCb detector are studied using the pseudomass method in proton-proton collision data recorded at centre of mass energy √s = 13 TeV during 2016, 2017 and 2018. The biases are determined using Z → μ+μ- decays in intervals defined by the data-taking period, magnet polarity and muon direction. Correcting for these biases, which are typically at the 10-4 GeV-1 level, improves the Z → μ+μ- mass resolution by roughly 18% and eliminates several pathological trends in the kinematic-dependence of the mean dimuon invariant mass

    Measurement of the CKM angle γ in the B0→DK *0 channel using self-conjugate D→ KS0h+ h- decays

    Get PDF
    A model-independent study of CP violation in B-0 -&gt; DK (*0) decays is presented using data corresponding to an integrated luminosity of 9 fb(-1) collected by the LHCb experiment at centre-of-mass energies of v s = 7, 8 and 13TeV. The CKM angle. is determined by examining the distributions of signal decays in phase-space bins of the self-conjugate D. K(S)(0)h(+) h(-) decays, where h = p, K. Observables related to CP violation are measured and the angle. is determined to be. = (49+22 -19).. Measurements of the amplitude ratio and strong-phase difference between the favoured and suppressed B-0 decays are also presented

    Introduction and Historical Review

    Get PDF

    Search for the Bs0 → μ+μ−γ decay

    Get PDF
    A search for the fully reconstructed B0 s → µ +µ −γ decay is performed at the LHCb experiment using proton-proton collisions at √ s = 13 TeV corresponding to an integrated luminosity of 5.4 fb−1 . No signifcant signal is found and upper limits on the branching fraction in intervals of the dimuon mass are set B(B 0 s → µ +µ −γ) &lt; 4.2 × 10−8 , m(µ +µ −) ∈ [2mµ, 1.70] GeV/c2 , B(B 0 s → µ +µ −γ) &lt; 7.7 × 10−8 , m(µ +µ −) ∈ [1.70, 2.88] GeV/c2 , B(B 0 s → µ +µ −γ) &lt; 4.2 × 10−8 , m(µ +µ −) ∈ [3.92, mB0 s ] GeV/c2 , at 95% confdence level. Additionally, upper limits are set on the branching fraction in the [2mµ, 1.70] GeV/c2 dimuon mass region excluding the contribution from the intermediate ϕ(1020) meson, and in the region combining all dimuon-mass intervals

    Curvature-bias corrections using a pseudomass method

    Get PDF
    Momentum measurements for very high momentum charged particles, such as muons from electroweak vector boson decays, are particularly susceptible to charge-dependent curvature biases that arise from misalignments of tracking detectors. Low momentum charged particles used in alignment procedures have limited sensitivity to coherent displacements of such detectors, and therefore are unable to fully constrain these misalignments to the precision necessary for studies of electroweak physics. Additional approaches are therefore required to understand and correct for these effects. In this paper the curvature biases present at the LHCb detector are studied using the pseudomass method in proton-proton collision data recorded at centre of mass energy √(s)=13 TeV during 2016, 2017 and 2018. The biases are determined using Z→μ + μ - decays in intervals defined by the data-taking period, magnet polarity and muon direction. Correcting for these biases, which are typically at the 10-4 GeV-1 level, improves the Z→μ + μ - mass resolution by roughly 18% and eliminates several pathological trends in the kinematic-dependence of the mean dimuon invariant mass
    corecore