774 research outputs found

    SPACE PATTERN OF FOREST SPECIES AND ITS RELATIONSHIP WITH AGRICULTURAL FACTORS AGROFLORESTAL SYSTEM

    Get PDF
    The objective of this work was to describe the spatial distribution pattern of the arboreal and regenerating forest stratum and its relationship with edaphic factors in a multistratified agroforestry system without management. The data were obtained by means of a census of the arboreal and regenerating plants, in which the variables diameter were measured at 1.30m of the soil and total height, besides the botanical identification. The plants of the arboreal stratum were grouped in diameter and height classes and the regenerating plants in height classes. In both strata, the horizontal structure indicators were estimated and the species of higher Importance Value Index (IVI) were selected to perform the spatial analysis. The K Ripley function was applied in the univariate case to test the hypothesis of complete randomness in the groups and in the arboreal and regenerating species of higher IVI. In the bivariate case, the Ripley K function was applied to test the hypothesis of complete spatial independence between groups or aggregate pattern species, with edaphic attributes. The results indicated random spatial pattern for most of the tested groups, with only the species Gliricidia sepium and Archontophoenix alexandrae with aggregate spatial pattern, up to 30m distance, in the arboreal and regenerating strata, respectively. However, no spatial relationship was observed between the pattern of distribution of the species and the soil factors of agroforestry system (SAF). In general, it is concluded that edaphic factors were fundamental in the development of plants, but not for the formation of aggregate

    Validação de protótipo de placa fotovoltaica híbrida: Validation of a hybrid photovoltaic prototype

    Get PDF
    Há várias pesquisas e estudos em busca de fontes de energia limpa e renovável, o trabalho presente tem por objetivo projetar, construir e validar um sistema com eficiência de geração de energia elétrica e térmica através de painéis fotovoltaicos refrigerados (híbridos), propiciando eficiência energética do painel fotovoltaico e, consequentemente, obter a geração de energia térmica com a energia dissipada pelo sistema. A metodologia foi através de uma revisão de literatura de renomados autores, livros e artigos científicos, bem como uma pesquisa aplicada através do desenho, construção e validação de um protótipo, os dados experimentais dos painéis foram coletados através de um sistema de datalooger, bem como a validação da modelagem por meio de análise de dados e comparação entre técnicas de captura de energia solar e resfriamento de painéis que melhor correspondam à eficiência do projeto. O painel fotovoltaico perde eficiência quando sua temperatura aumenta. A partir do estudo e experimentos que foram realizados, concluiu-se que o painel refrigerado proporciona uma maior geração de energia elétrica em relação ao não resfriado e consequentemente já aquece a água, obtendo assim um melhor aproveitamento de energia

    Lower urinary tract symptoms and sexual dysfunction in men with multiple sclerosis

    Get PDF
    OBJECTIVES: To assess the prevalence and interrelationship between lower urinary tract symptoms and sexual dysfunction in men with multiple sclerosis (MS). METHODS: In a cross-sectional study, we evaluated 41 men (mean age 41.1±9.9 years) with MS from February 2011 to March 2013, who were invited to participate irrespective of the presence of lower urinary tract symptoms or sexual dysfunction. Neurological impairment was assessed with the Expanded Disability Status Scale; lower urinary tract symptoms were evaluated with the International Continence Society male short-form questionnaire, and sexual dysfunction was evaluated with the International Index of Erectile Function. All patients underwent transabdominal urinary tract sonography and urine culture. RESULTS: The mean disease duration was 10.5±7.3 years. Neurological evaluation showed a median Expanded Disability Status Scale score of 3 [2-6]. The median International Continence Society male short-form questionnaire score was 17 [10-25]. The median International Index of Erectile Function score was 29 [15-46]. Twentynine patients (74.4%) had sexual dysfunction as defined by an International Index of Erectile Function score o45. Voiding dysfunction and sexual dysfunction increased with the degree of neurological impairment (r=0.02 [0.02 to 0.36] p=0.03 and r=-0.41 [-0.65 to -0.11] p=0.008, respectively). Lower urinary tract symptoms and sexual dysfunction also displayed a significant correlation (r=-0.31 [-0.56 to -0.01] p=0.04). CONCLUSIONS: Most male patients with MS have lower urinary tract symptoms and sexual dysfunction. The severity of the neurological disease is a predictive factor for the occurrence of voiding and sexual dysfunctions

    Evaluation of the buccal vestibule-palatal diffusion of 4% articaine hydrochloride in impacted maxillary third molar extractions

    Get PDF
    Aims: The aim of this study was to evaluate the vestibular-palatal diffusion of 4% articaine with epinephrine 1:100,000 and 1:200,000, in impacted maxillary third molar extractions, without palatal injection. Materials and Method: Two hundred teeth were selected from patients age 15 to 46. Patients were divided into 4 groups: 1A, were anesthetized with 4% articaine 1:100,000 and the surgery was initiated 5 minutes following anesthesia. 1B, used 4% articaine 1:100,000 but the surgery was started 10 minutes after anesthesia. 2A, used 4% articaine 1:200,000 the surgery was started 5 minutes after. 2B, used 4% articaine 1:200,000 but 10 minutes was allowed for anesthetic diffusion before the initiation of in groups (50 extractions each) only buccal vestibule anesthesia was initially administered (i.e. no palatal injections were used). Results: The rate of sufficient vestibule-palatal diffusion, as determined by the lack of necessity of supplemental palatal anesthesia, was: 1A(84%), 1B(98%), 2A(78%), 2B(82%). Chi-square (X2) and residual analyses showed that a higher vestibule-palatal diffusion was obtained using 4% articaine 1:100,000 with a period of 10 minutes (p<0.05). Conclusions: Most of the extractions could be performed only with vestibule anesthesia. However, vasoconstrictor concentration and the time interval between administration of the anesthetic and initiation of surgery did influence buccal vestibule-palatal diffusion of 4% articaine in the extraction models used

    O Impacto da digitalização no processo produtivo de injeção plástica

    Get PDF
    A competitividade perpassa vários fatores organizacionais, dentre eles o controle por meio de indicadores da produtividade. Nesse sentido, a digitalização da manufatura tornou-se necessária para o efetivo controle da função de produção nas indústrias. Com essas premissas, o presente estudo procurou avaliar o impacto da digitalização na gestão da produção em uma empresa do Polo Industrial de Manaus que utiliza a injeção plástica como processo produtivo. Para avaliar o grau de impacto da digitalização foram coletados dados e a forma de controle do processo, por meio dos registros históricos da produção nos últimos seis meses. As variáveis consideradas foram: índice de rejeição por problemas de qualidade, produtividade e custos de produção. Com a digitalização do processo de gestão, os resultados mostraram melhoria no índice de defeitos, aumento das quantidades produzidas e redução de custos de produção

    Avaliação clínica de inlays e onlays confeccionadas com dois tipos de cerâmica, após 06 meses

    Get PDF
    The aim of the present study was to evaluate the clinical performance of two types of ceramics: a slurry-powder ceramic (Duceram Plus, Degussa) - D and a hot-pressed leucite-based glass-ceramic (IPS Empress, Ivoclar Vivadent) - IPS. Eighty-six restorations, 44 IPS and 42 D, were made by one operator. A total of 33 onlays and 53 inlays on twenty-seven premolars and 59 molars were cemented in 35 patients of both sexes, mean age 35 years. All restorations were cemented with the dual-resin cement (Variolink, Ivoclar-Vivadent) under rubber dam and were evaluated at the baseline and after six months, using the modified U.S.P.H.S. criteria for postoperative sensitivity, secondary caries, fracture, color match, marginal discoloration, marginal integrity and surface texture. Additionally radiographs and intraoral photographs were carried out. At baseline 86 restorations were analyzed and all of them received Alfa rating, except for the following that received Bravo rating for postoperative sensitivity - IPS (2.27%); D (7.14%); for color match - IPS (2.27%); D (2.38%) and for surface texture - IPS (2.27%); D (11.90%). After 6 months 100% of the restorations were analyzed and the following received Bravo rating: color match - IPS (4.55%) and D (9.52%); surface texture - IPS (2.27%) and D (11.9%); marginal discoloration - IPS (6.82%) and D (4.76%) and marginal integrity - IPS (4.55%) and D (7.14%). The results were submitted to the Fisher and McNemar Statistical Tests. No significant differences were noticed between the two ceramics. Both ceramics demonstrated satisfactory clinical performance after six months.Este trabalho se propôs a avaliar a performance clínica de dois tipos de cerâmica: IPS Empress, Ivoclar-Vivadent - IPS e Duceram Plus, Degussa - D. Foram realizadas 86 restaurações por apenas um operador, sendo 44 IPS e 42 D. Vinte e sete pré-molares e 59 molares, num total de 33 onlays e 53 inlays, foram cimentadas em 35 pacientes de ambos os sexos, com idade média de 35 anos. A cimentação das restaurações foi realizada com cimento resinoso dual (Variolink, Ivoclar-Vivadent) sob isolamento absoluto e avaliadas no baseline e após 06 meses, mediante o critério U.S.P.H.S. modificado, quanto à sensibilidade pulpar, reincidência de cárie, fratura, reprodução de cor, descoloração marginal, integridade marginal e textura superficial. Adicionalmente foram realizadas radiografias e fotografias. No baseline foi obtida a classificação Bravo nos itens sensibilidade pulpar - IPS (2,27%); D (7,14%); reprodução de cor - IPS (2,27%); D (2,38%) e textura superficial - IPS (2,27%); D (11,90%). Após 06 meses foram analisadas as 86 restaurações, nas quais foi constatada a classificação Bravo para os itens reprodução de cor - IPS (6,82%); D (2,38%); textura superficial - IPS (2,27%); D (9,52%); descoloração marginal - IPS (6,82%); D (4,76%) e integridade de superfície- IPS (4,55%); D (7,14%). Os resultados obtidos foram submetidos ao Teste Estatístico de Fisher e McNemar. Não houve diferença estatisticamente significante entre as cerâmicas. Pode-se concluir que os dois tipos de cerâmica demonstraram uma performance clínica satisfatória após 06 meses

    Proposta de Quadro de Transferência Automático de baixo custo para Instalações Elétricas de pequeno porte

    Get PDF
    Disponibilizar geradores como fonte adicional de energia elétrica para instalações elétricas comerciais e industriais, em paralelo ou independente da rede da concessionária, é procedimento comum, e tem por finalidade prover energia a partir de fonte secundária, pela alternância total com a rede comercial. A prática visa redução de custos tarifários em horário de ponta e composição de sistema emergencial de fornecimento de energia em caso de interrupção da concessionária, evitando-se efeitos de paradas em processos críticos. Nessas instalações, por envolverem demandas elevadas de potência, Quadro de Transferência Automático (QTA) é em geral empregado, para a comutação entre as fontes, constatando-se alta viabilidade técnica e econômica. Em instalações elétricas de baixa demanda, como as residenciais, geradores com potências nominais da ordem de 4 a 15 kVA são empregados, e o uso de um QTA não é comum, principalmente por questões econômicas. Por aspectos construtivos, boa parte dessas máquinas, embora com partida elétrica, não são totalmente automatizadas. QTA’s comerciais podem ser adaptados, mas os custos não são, em geral, compensadores. Este trabalho aborda tal questão, e versa sobre um QTA em proveito de instalações de baixa demanda. Propõe o desenvolvimento de sistema de baixo custo, com base em microcontrolador de plataforma aberta e princípio de atuação e funcionalidades similares às existentes em produtos comercialmente disponíveis para geradores de potência inferior a 15 kVA. O hardware proposto, além da placa eletrônica de controle, conta com Relés de Interface, Relés Falta de Fase e Contatores Magnéticos, sendo as funções integradas a um display indicador de estados. O trabalho realizado envolveu ações que abrangeram desde os estudos iniciais para concepção, dimensionamento e especificações de componentes eletroeletrônicos, até o desenvolvimento de protocolos de monitoramento e acionamento, bem como toda a programação da plataforma na linguagem pertinente. Sistema modular, potencialmente vantajoso para o projeto, foi concebido com base em dois principais módulos: de comando e de potência, o que permite ajustes técnicos com mais eficiência e facilidade na análise. Permitir adequação a situações diversas representa também vantagem dessa modularidade. Simulações permitiram concluir pela adequação do projeto e suas funcionalidades. Viabilidade técnica e econômica também se visualizam, com custos vantajosos, comparados aos produtos similares disponíveis no mercado

    Estudo do aproveitamento do calor dissipado em condensadores de ares condicionados para aquecimento da água para o banho/ Study on the use of dissipated heat in air conditioners for heating water for the bath

    Get PDF
     O Brasil é o país em que as pessoas tomam mais banho no mundo. Em média, toma 20 banhos por semana. Desta forma, os chuveiros elétricos são um dos principais consumidores de energia nas residências brasileiras. Outro equipamento com significativo consumo de energia é o ar condicionado. Contudo, a quantidade de energia que é liberada no ar condicionado é muito superior, podendo esta ser mais do que 5 vezes a quantidade de energia consumida. Esse calor é dissipado na unidade condensadora dos aparelhos de ar condicionado, diante disto, este trabalho tem por objetivo, estudar a viabilidade de se aproveitar este calor para o aquecimento da água utilizada no banho. O trabalho analisa o potencial impacto econômico que isto causaria e o comportamento da troca térmica, entre o condensador de uma bancada de refrigeração e a água. Os resultados foram promissores, mediante a água ter alcançado uma temperatura acima da de conforto
    corecore