13 research outputs found
Rasch analysis of the Patient and Observer Scar Assessment Scale (POSAS) in burn scars
The Patient and Observer Scar Assessment Scale (POSAS) is a questionnaire that was developed to assess scar quality. It consists of two separate six-item scales (Observer Scale and Patient Scale), both of which are scored on a 10-point rating scale. After many years of experience with this scale in burn scar assessment, it is appropriate to examine its psychometric properties using Rasch analysis. Cross-sectional data collection from seven clinical trials resulted in a data set of 1,629 observer scores and 1,427 patient scores of burn scars. We examined the person-item map, item fit statistics, reliability, response category ordering, and dimensionality of the POSAS. The POSAS showed an adequate fit to the Rasch model, except for the item surface area. Person reliability of the Observer Scale and Patient Scale was 0.82 and 0.77, respectively. Dimensionality analysis revealed that the unexplained variance by the first contrast of both scales was 1.7 units. Spearman correlation between the Observer Scale Rasch measure and the overall opinion of the clinician was 0.75. The Rasch model demonstrated that the POSAS is a reliable and valid scale that measures the single-construct scar qualit
Recommended from our members
Detection of OH+ and H2O+ towards Orion KL
We report observations of the reactive molecular ions OH+, H2O+, and H3O+ towards Orion KL with Herschel/HIFI. All three N = 1-0 fine-structure transitions of OH+ at 909, 971, and 1033 GHz and both fine-structure components of the doublet ortho-H2O+ 111–000 transition at 1115 and 1139 GHz were detected; an upper limit was obtained for H3O+. OH+ and H2O+ are observed purely in absorption, showing a narrow component at the source velocity of 9 km s-1, and a broad blueshifted absorption similar to that reported recently for HF and para-H218O, and attributed to the low velocity outflow of Orion KL. We estimate column densities of OH+ and H2O+ for the 9 km s-1 component of 9 ± 3 × 1012 cm-2 and 7 ± 2 × 1012 cm-2, and those in the outflow of 1.9 ± 0.7 × 1013 cm-2 and 1.0 ± 0.3 × 1013 cm-2. Upper limits of 2.4 × 1012 cm-2 and 8.7 × 1012 cm-2 were derived for the column densities of ortho and para-H3O+ from transitions near 985 and 1657 GHz. The column densities of the three ions are up to an order of magnitude lower than those obtained from recent observations of W31C and W49N. The comparatively low column densities may be explained by a higher gas density despite the assumption of a very high ionization rate
Melanin pigments in the melanocytic nevus regress spontaneously after inactivation by high hydrostatic pressure
We report a novel treatment for giant congenital melanocytic nevi (GCMN) that involves the reuse of resected nevus tissue after high hydrostatic pressurization (HHP). However, the remaining melanin pigments in the inactivated nevus tissue pose a problem; therefore, we performed a long-term observation of the color change of inactivated nevus tissue after HHP. Pressurized nevus specimens (200 MPa group, n = 9) and non-pressurized nevus tissues (control group, n = 9) were subcutaneously implanted into nude mice (BALB/c-nu) and then harvested 3, 6, and 12 months later. Color changes of the nevus specimens were evaluated. In the 200 MPa group, the specimen color gradually regressed and turned white, and brightness values were significantly higher in the 200 MPa group than in the control group after 6 months. This indicated that melanin pigments in the pressurized nevus tissue had spontaneously degraded and regressed. Therefore, it is not necessary to remove melanin pigments in HHP-treated nevus tissue