155 research outputs found
Chloride Ions in the Pore of Glycine and GABA Channels Shape the Time Course and Voltage Dependence of Agonist Currents
In the vertebrate CNS, fast synaptic inhibition is mediated by GABA and glycine receptors. We recently reported that the time course of these synaptic currents is slower when intracellular chloride is high. Here we extend these findings to measure the effects of both extracellular and intracellular chloride on the deactivation of glycine and GABA currents at both negative and positive holding potentials. Currents were elicited by fast agonist application to outside-out patches from HEK-293 cells expressing rat glycine or GABA receptors. The slowing effect of high extracellular chloride on current decay was detectable only in low intracellular chloride (4 mM). Our main finding is that glycine and GABA receptors "sense" chloride concentrations because of interactions between the M2 pore-lining domain and the permeating ions. This hypothesis is supported by the observation that the sensitivity of channel gating to intracellular chloride is abolished if the channel is engineered to become cation selective or if positive charges in the external pore vestibule are eliminated by mutagenesis. The appropriate interaction between permeating ions and channel pore is also necessary to maintain the channel voltage sensitivity of gating, which prolongs current decay at depolarized potentials. Voltage dependence is abolished by the same mutations that suppress the effect of intracellular chloride and also by replacing chloride with another permeant ion, thiocyanate. These observations suggest that permeant chloride affects gating by a foot-in-the-door effect, binding to a channel site with asymmetrical access from the intracellular and extracellular sides of the membrane
Single-layer graphene modulates neuronal communication and augments membrane ion currents
The use of graphenebased materials to engineer sophisticated biosensing interfaces that can adapt to the central nervous system requires a detailed understanding of how such materials behave in a biological context. Graphene's peculiar properties can cause various cellular changes, but the underlying mechanisms remain unclear. Here, we show that singlelayer graphene increases neuronal firing by altering membraneassociated functions in cultured cells. Graphene tunes the distribution of extracellular ions at the interface with neurons, a key regulator of neuronal excitability. The resulting biophysical changes in the membrane include stronger potassium ion currents, with a shift in the fraction of neuronal firing phenotypes from adapting to tonically firing. By using experimental and theoretical approaches, we
hypothesize that the graphene\u2013ion interactions that are maximized when singlelayer graphene is deposited on electrically insulating substrates are crucial to these effects
Immunogenicity and efficacy of oral vaccines in developing countries: lessons from a live cholera vaccine
Oral vaccines, whether living or non-living, viral or bacterial, elicit diminished immune responses or have lower efficacy in developing countries than in developed countries. Here I describe studies with a live oral cholera vaccine that include older children no longer deriving immune support from breast milk or maternal antibodies and that identify some of the factors accounting for the lower immunogenicity, as well as suggesting counter-measures that may enhance the effectiveness of oral immunization in developing countries. The fundamental breakthrough is likely to require reversing effects of the 'environmental enteropathy' that is often present in children living in fecally contaminated, impoverished environments
Precision measurement of violation in the penguin-mediated decay
A flavor-tagged time-dependent angular analysis of the decay
is performed using collision data collected
by the LHCb experiment at % at TeV, the center-of-mass energy of
13 TeV, corresponding to an integrated luminosity of 6 fb^{-1}. The
-violating phase and direct -violation parameter are measured
to be rad and
, respectively, assuming the same values
for all polarization states of the system. In these results, the
first uncertainties are statistical and the second systematic. These parameters
are also determined separately for each polarization state, showing no evidence
for polarization dependence. The results are combined with previous LHCb
measurements using collisions at center-of-mass energies of 7 and 8 TeV,
yielding rad and . This is the most precise study of time-dependent violation
in a penguin-dominated meson decay. The results are consistent with
symmetry and with the Standard Model predictions.Comment: All figures and tables, along with any supplementary material and
additional information, are available at
https://cern.ch/lhcbproject/Publications/p/LHCb-PAPER-2023-001.html (LHCb
public pages
Measurement of the differential branching fraction
The branching fraction of the rare decay is measured for the first time, in the squared dimuon mass
intervals, , excluding the and regions. The data
sample analyzed was collected by the LHCb experiment at center-of-mass energies
of 7, 8, and 13 TeV, corresponding to a total integrated luminosity of $9\
\mathrm{fb}^{-1}q^{2}q^{2} >15.0\
\mathrm{GeV}^2/c^4$, where theoretical predictions have the smallest model
dependence, agrees with the predictions.Comment: All figures and tables, along with any supplementary material and
additional information, are available at
https://cern.ch/lhcbproject/Publications/p/LHCb-PAPER-2022-050.html (LHCb
public pages
- âŠ