5,955 research outputs found
Evaluation of the first automated thyroglobulin assay
The aim of this study was to investigate technical and analytical performance of the first automated thyroglobulin (Tg) assay (DPC-Immulite(R); Diagnostic Products Corporation, Los Angeles, USA). In imprecision studies using several human serum pools ranging from 21 to 58 replicates, a coefficient of variation of 9.0 % was obtained at a mean Tg concentration of 0.84 ng/ml and of 6.1 % at a Tg concentration of 62.1 ng/ml. In a method comparison with a non-automated assay (BRAHMS LUMItest Tg(R), BRAHMS, Berlin, Germany) using 383 sera of 303 patients with thyroid carcinoma, regression analysis according to Passing and Bablock yielded in the following equation: Immulite Tg=1.6 x BRAHMS Tg - 0.1 ng/ml (Pearson's r=0.979). Sera obtained from 59 patients with thyroid carcinoma enabled comparative follow-up studies; in all cases qualitative agreement was found with regard to increase or decrease of serum Tg; in eight cases, however, Tg was detected with the Immulite assay but not with the BRAHMS assay. Further follow-up proved the presence of thyroid tissue in these patients. From these and further methodological data (dilution linearity, interference studies, carry-over study, high-dose hook properties, and short report time) it is concluded that the DPC-Immulite Tg assay meets the requirements of routine diagnostic use
Toward CP-even Neutrino Beam
The best method of measuring CP violating effect in neutrino oscillation
experiments is to construct and use a neutrino beam made of an ideal mixture of
and of monochromatic lines. The conceptual design of such
a beam is described, together with how to measure the CP-odd quantity. We
propose to exploit an accelerated unstable hydrogen-like heavy ion in a storage
ring, whose decay has both electron capture and bound beta decay with a
comparable fraction.Comment: 6 pages, 2 figures, Published versio
Comparison of a fully automated immunoassay with a point-of-care testing method for B-type natriuretic peptide
Increased circulating concentration of interluekin 2 receptor during rejection episodes in heart- or kidney-transplant recipients
Linear regression models and k-means clustering for statistical analysis of fNIRS data
We propose a new algorithm, based on a linear regression model, to statistically estimate the hemodynamic activations in fNIRS data sets. The main concern guiding the algorithm development was the minimization of assumptions and approximations made on the data set for the application of statistical tests. Further, we propose a K-means method to cluster fNIRS data (i.e. channels) as activated or not activated. The methods were validated both on simulated and in vivo fNIRS data. A time domain (TD) fNIRS technique was preferred because of its high performances in discriminating cortical activation and superficial physiological changes. However, the proposed method is also applicable to continuous wave or frequency domain fNIRS data sets
Neutrino tomography - Learning about the Earth's interior using the propagation of neutrinos
Because the propagation of neutrinos is affected by the presence of Earth
matter, it opens new possibilities to probe the Earth's interior. Different
approaches range from techniques based upon the interaction of high energy
(above TeV) neutrinos with Earth matter, to methods using the MSW effect on the
neutrino oscillations of low energy (MeV to GeV) neutrinos. In principle,
neutrinos from many different sources (sun, atmosphere, supernovae, beams etc.)
can be used. In this talk, we summarize and compare different approaches with
an emphasis on more recent developments. In addition, we point out other
geophysical aspects relevant for neutrino oscillations.Comment: 22 pages, 9 figures. Proceedings of ``Neutrino sciences 2005:
Neutrino geophysics'', December 14-16, 2005, Honolulu, USA. Minor changes,
some references added. Final version to appear in Earth, Moon, and Planet
The acceleration and storage of radioactive ions for a neutrino factory
The term beta-beam has been coined for the production of a pure beam of
electron neutrinos or their antiparticles through the decay of radioactive ions
circulating in a storage ring. This concept requires radioactive ions to be
accelerated to a Lorentz gamma of 150 for 6He and 60 for 18Ne. The neutrino
source itself consists of a storage ring for this energy range, with long
straight sections in line with the experiment(s). Such a decay ring does not
exist at CERN today, nor does a high-intensity proton source for the production
of the radioactive ions. Nevertheless, the existing CERN accelerator
infrastructure could be used as this would still represent an important saving
for a beta-beam facility. This paper outlines the first study, while some of
the more speculative ideas will need further investigations.Comment: Accepted for publication in proceedings of Nufact02, London, 200
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
Hemodynamic and EEG Time-Courses During Unilateral Hand Movement in Patients with Cortical Myoclonus. An EEG-fMRI and EEG-TD-fNIRS Study.
Multimodal human brain mapping has been proposed as an integrated approach capable of improving the recognition of the cortical correlates of specific neurological functions. We used simultaneous EEG-fMRI (functional magnetic resonance imaging) and EEG-TD-fNIRS (time domain functional near-infrared spectroscopy) recordings to compare different hemodynamic methods with changes in EEG in ten patients with progressive myoclonic epilepsy and 12 healthy controls. We evaluated O(2)Hb, HHb and Blood oxygen level-dependent (BOLD) changes and event-related desynchronization/synchronization (ERD/ERS) in the alpha and beta bands of all of the subjects while they performed a simple motor task. The general linear model was used to obtain comparable fMRI and TD-fNIRS activation maps. We also analyzed cortical thickness in order to evaluate any structural changes. In the patients, the TD-NIRS and fMRI data significantly correlated and showed a significant lessening of the increase in O(2)Hb and the decrease in BOLD. The post-movement beta rebound was minimal or absent in patients. Cortical thickness was moderately reduced in the motor area of the patients and correlated with the reduction in the hemodynamic signals. The fMRI and TD-NIRS results were consistent, significantly correlated and showed smaller hemodynamic changes in the patients. This finding may be partially attributable to mild cortical thickening. However, cortical hyperexcitability, which is known to generate myoclonic jerks and probably accounts for the lack of EEG beta-ERS, did not reflect any increased energy requirement. We hypothesize that this is due to a loss of inhibitory neuronal components that typically fire at high frequencies
- …