169 research outputs found

    In situ remediation of contaminated marinesediment: an overview

    Get PDF
    Sediment tends to accumulate inorganic and persistent hydrophobic organic contaminants representing one of the main sinks and sources of pollution. Generally, contaminated sediment poses medium- and long-term risks to humans and ecosystem health; dredging activities or natural resuspension phenomena (i.e., strongly adverse weather conditions) can remobilize pollution releasing it into the water column. Thus, ex situ traditional remediation activities (i.e., dredging) can be hazardous compared to in situ techniques that try to keep to a minimum sediment mobilization, unless dredging is compulsory to reach a desired bathymetric level. We reviewed in situ physico-chemical (i.e., active mixing and thin capping, solidification/stabilization, chemical oxidation, dechlorination, electrokinetic separation, and sediment flushing) and bio-assisted treatments, including hybrid solutions (i.e., nanocomposite reactive capping, bioreactive capping, microbial electrochemical technologies). We found that significant gaps still remain into the knowledge about the application of in situ contaminated sediment remediation techniques from the technical and the practical viewpoint. Only activated carbon-based technologies are well developed and currently applied with several available case studies. The environmental implication of in situ remediation technologies was only shortly investigated on a long-term basis after its application, so it is not clear how they can really perform

    Antenna Deployment for a Pathfinder Lunar Radio Observatory

    Get PDF
    A first step in the development of a large radio observatory on the moon for cosmological or other astrophysical and planetary goals is to deploy a few antennas as a pathfinder mission. In this presentation, we describe a mechanism being developed to deploy such antennas from a small craft, such as a Google Lunar X-prize lander. The antenna concept is to deposit antennas and leads on a polyimide film, such as Kapton, and to unroll the film on the lunar surface. The deployment technique utilized is to launch an anchor which pulls a double line from a reel at the spacecraft. Subsequently, the anchor is set by catching on the surface or collecting sufficient regolith. A motor then pulls in one end of the line, pulling the film off of its roller onto the lunar surface. Detection of a low frequency cutoff of the galactic radio background or of solar radio bursts by such a system would determine the maximum lunar ionospheric density at the time of measurement. The current design and testing, including videos of the deployment, will be presented. These activities are funded in part by the NASA Lunar Science Institute as an activity of the Lunar University Network for Astrophysical Research (LUNAR) consortium. Part of this research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration

    Characterization of the stimulation output of four devices for focal muscle vibration

    Get PDF
    Different devices for mechano-acoustic muscle vibration became available on the market in the last ten years. Although the use of these vibrators is increasing in research and clinical settings, the features of their stimulation output were never described in literature. In this study we aimed to quantify and compare the stimulation output of the four most widespread pneumatic devices for focal muscle vibration available on the market. A piezoelectric pressure sensor was used to measure the pressure profile generated by the four selected devices in the following experimental conditions: i) measurement of the output changes associated with variations of the stimulation amplitude for three stimulation frequencies (100 Hz, 200 Hz, and 300 Hz); ii) measurement of the output changes during a 20-min long stimulation at constant frequency (300 Hz) and amplitude; iii) measurement of the output changes associated with the progressive activation of all stimulation channels at constant frequency (200 Hz) for different amplitudes. The maximum peak-to-peak amplitudes of the pressure waves were in the range 102 mbar - 369 mbar (below the maximum values declared by the different manufacturers). The shape of the pressure waves generated by the four devices was quasi-sinusoidal and asymmetric with respect to the atmospheric pressure. All output features had a remarkable intra- and inter-device variability. Further studies are required to support the technological improvement of the currently available devices and to focus the issues of vibration effectiveness, limitations, proper protocols, modalities of its application and assessment in neuromuscular training and rehabilitation

    Diagnostic performance of the Strength and Pain Assessment (SPA) score for non-contact muscle injury screening in male soccer players

    Get PDF
    Objectives: The aims of this study were to develop a clinical-feature based scoring system for muscle injury screening and to assess its diagnostic accuracy when large number of injuries are suspected. Methods: A prospective diagnostic accuracy study was performed according to the Standards for Reporting of Diagnostic Accuracy (STARD) criteria. The diagnostic accuracy of the Strength and Pain Assessment (SPA) score (index test) was assessed in relation to muscle ultrasonography (reference standard). A large (n = 175) number of male soccer players met the inclusion/exclusion criteria: clinical assessment (i.e., evaluation of pain onset modality, location, distribution, impact on performance, and manual muscle strength testing) and ultrasonography were performed in all players after 48 hours from the sudden or progressive onset of muscle pain during or after a soccer competition. Results: 91 of 175 cases (52%) were classified as functional muscle disorders, while signs of muscle tear were observed in the remaining 84 of 175 (48%) cases that were classified as structural muscle injuries. The median (1st–3rd quartile) value of the SPA score was significantly (P < 0.001) lower in the functional disorder group [9 (9–10)] compared to the structural injury group [12 (12–13)]. The area under the Receiver Operating Characteristic curve for different cutoff points of the SPA score was 0.977 (95% confidence intervals: 0.957–0.998) and the optimal cutoff value of the SPA score providing the greatest sensitivity and specificity (respectively, 99% and 89%) was 11. Conclusion: This study found that the SPA score has high diagnostic accuracy for structural muscle injuries and could be used as a valid screening tool in soccer players presenting with sudden or progressive onset of muscle pain during or after a competition

    POINT MUTATIONS IN THE TYROSINE KINASE DOMAIN RELEASE THE ONCOGENIC AND METASTATIC POTENTIAL OF THE RON RECEPTOR

    Get PDF

    Influence of a montmorency cherry juice blend on indices of exercise-induced stress and upper respiratory tract symptoms following marathon running—a pilot investigation

    Get PDF
    Background: Prolonged exercise, such as marathon running, has been associated with an increase in respiratory mucosal inflammation. The aim of this pilot study was to examine the effects of Montmorency cherry juice on markers of stress, immunity and inflammation following a Marathon. Methods: Twenty recreational Marathon runners consumed either cherry juice (CJ) or placebo (PL) before and after a Marathon race. Markers of mucosal immunity secretory immunoglobulin A (sIgA), immunoglobulin G (IgG), salivary cortisol, inflammation (CRP) and self-reported incidence and severity of upper respiratory tract symptoms (URTS) were measured before and following the race. Results: All variables except secretory IgA and IgG concentrations in saliva showed a significant time effect (P < 0.01). Serum CRP showed a significant interaction and treatment effect (P < 0.01). The CRP increase at 24 and 48 h post-Marathon was lower (P < 0.01) in the CJ group compared to PL group. Mucosal immunity and salivary cortisol showed no interaction effect or treatment effect. The incidence and severity of URTS was significantly greater than baseline at 24 h and 48 h following the race in the PL group and was also greater than the CJ group (P < 0.05). No URTS were reported in the CJ group whereas 50 % of runners in the PL group reported URTS at 24 h and 48 h post-Marathon. Conclusions: This is the first study that provides encouraging evidence of the potential role of Montmorency cherries in reducing the development of URTS post-Marathon possibly caused by exercise-induced hyperventilation trauma, and/or other infectious and non-infectious factors

    Establishing a Search String to Detect Secondary Studies in Software Engineering

    Full text link
    Search for secondary studies is essential to establish whether the review on the intended topic has already been done, avoiding waste time. In addition, secondary studies are the inputs of a tertiary study. However, one critical step in searching for secondary studies is to elaborate a search string. The main goal of this work is to analyze search strings to establish directions to better detect secondary studies in Software Engineering (SE). We analyzed seven tertiary studies under two perspectives: (1) structure - strings' terms to detect secondary studies; and (2) field: where searching - titles alone or abstracts alone or titles and abstracts together, among others. We also performed a validation of the results found. The suitable search string for finding secondary studies in SE contain the terms "systematic review", "literature review", "systematic mapping", "mapping study", "systematic map", "meta-analysis", "survey" and "literature analysis". Furthermore, we recommend (1) researchers use the title, abstract and keywords search fields in their searches to increase studies recall; (2) researchers choose carefully their paper title, abstract and keyword terms to increase the chance of having such studies found on digital libraries
    corecore