1,788 research outputs found
Physical realizations of quantum operations
Quantum operations (QO) describe any state change allowed in quantum
mechanics, such as the evolution of an open system or the state change due to a
measurement. We address the problem of which unitary transformations and which
observables can be used to achieve a QO with generally different input and
output Hilbert spaces. We classify all unitary extensions of a QO, and give
explicit realizations in terms of free-evolution direct-sum dilations and
interacting tensor-product dilations. In terms of Hilbert space dimensionality
the free-evolution dilations minimize the physical resources needed to realize
the QO, and for this case we provide bounds for the dimension of the ancilla
space versus the rank of the QO. The interacting dilations, on the other hand,
correspond to the customary ancilla-system interaction realization, and for
these we derive a majorization relation which selects the allowed unitary
interactions between system and ancilla.Comment: 8 pages, no figures. Accepted for publication on Phys. Rev.
Information-Disturbance Tradeoff in Quantum State Discrimination
When discriminating between two pure quantum states, there exists a
quantitative tradeoff between the information retrieved by the measurement and
the disturbance caused on the unknown state. We derive the optimal tradeoff and
provide the corresponding quantum measurement. Such an optimal measurement
smoothly interpolates between the two limiting cases of maximal information
extraction and no measurement at all.Comment: 5 pages, 2 (low-quality) figures. Eq. (20) corrected. Final published
versio
Improving information/disturbance and estimation/distortion trade-offs with non universal protocols
We analyze in details a conditional measurement scheme based on linear
optical components, feed-forward loop and homodyne detection. The scheme may be
used to achieve two different tasks. On the one hand it allows the extraction
of information with minimum disturbance about a set of coherent states. On the
other hand, it represents a nondemolitive measurement scheme for the
annihilation operator, i.e. an indirect measurement of the Q-function. We
investigate the information/disturbance trade-off for state inference and
introduce the estimation/distortion trade-off to assess estimation of the
Q-function. For coherent states chosen from a Gaussian set we evaluate both
information/disturbance and estimation/distortion trade-offs and found that non
universal protocols may be optimized in order to achieve better performances
than universal ones. For Fock number states we prove that universal protocols
do not exist and evaluate the estimation/distortion trade-off for a thermal
distribution.Comment: 10 pages, 6 figures; published versio
Entanglement dynamics of electron-electron scattering in low-dimensional semiconductor systems
We perform the quantitative evaluation of the entanglement dynamics in
scattering events between two insistinguishable electrons interacting via
Coulomb potential in 1D and 2D semiconductor nanostructures. We apply a
criterion based on the von Neumann entropy and the Schmidt decomposition of the
global state vector suitable for systems of identical particles. From the
timedependent numerical solution of the two-particle wavefunction of the
scattering carriers we compute their entanglement evolution for different spin
configurations: two electrons with the same spin, with different spin, singlet,
and triplet spin state. The procedure allows to evaluate the mechanisms that
govern entanglement creation and their connection with the characteristic
physical parameters and initial conditions of the system. The cases in which
the evolution of entanglement is similar to the one obtained for
distinguishable particles are discussed.Comment: 22 pages, 7 figures, submitted to Physical Review
Carrier-carrier entanglement and transport resonances in semiconductor quantum dots
We study theoretically the entanglement created in a scattering between an
electron, incoming from a source lead, and another electron bound in the ground
state of a quantum dot, connected to two leads. We analyze the role played by
the different kinds of resonances in the transmission spectra and by the number
of scattering channels, into the amount of quantum correlations between the two
identical carriers. It is shown that the entanglement between their energy
states is not sensitive to the presence of Breit-Wigner resonances, while it
presents a peculiar behavior in correspondence of Fano peaks: two close maxima
separated by a minimum, for a two-channel scattering, a single maximum for a
multi-channel scattering. Such a behavior is ascribed to the different
mechanisms characterizing the two types of resonances. Our results suggest that
the production and detection of entanglement in quantum dot structures may be
controlled by the manipulation of Fano resonances through external fields.Comment: 8 pages, 6 figures, RevTex4 two-column format, submitte
On demand entanglement in double quantum dots via coherent carrier scattering
We show how two qubits encoded in the orbital states of two quantum dots can
be entangled or disentangled in a controlled way through their interaction with
a weak electron current. The transmission/reflection spectrum of each scattered
electron, acting as an entanglement mediator between the dots, shows a
signature of the dot-dot entangled state. Strikingly, while few scattered
carriers produce decoherence of the whole two-dots system, a larger number of
electrons injected from one lead with proper energy is able to recover its
quantum coherence. Our numerical simulations are based on a real-space solution
of the three-particle Schroedinger equation with open boundaries. The computed
transmission amplitudes are inserted in the analytical expression of the system
density matrix in order to evaluate the entanglement.Comment: 20 pages, 5 figure
Non-invasive diagnostic biomarkers for estimating the onset time of permanent cerebral ischemia.
The treatments for ischemic stroke can only be administered in a narrow time-window. However, the ischemia onset time is unknown in ~30% of stroke patients (wake-up strokes). The objective of this study was to determine whether MR spectra of ischemic brains might allow the precise estimation of cerebral ischemia onset time. We modeled ischemic stroke in male ICR-CD1 mice using a permanent middle cerebral artery filament occlusion model with laser Doppler control of the regional cerebral blood flow. Mice were then subjected to repeated MRS measurements of ipsilateral striatum at 14.1 T. A striking initial increase in γ-aminobutyric acid (GABA) and no increase in glutamine were observed. A steady decline was observed for taurine (Tau), N-acetyl-aspartate (NAA) and similarly for the sum of NAA+Tau+glutamate that mimicked an exponential function. The estimation of the time of onset of permanent ischemia within 6 hours in a blinded experiment with mice showed an accuracy of 33±10 minutes. A plot of GABA, Tau, and neuronal marker concentrations against the ratio of acetate/NAA allowed precise separation of mice whose ischemia onset lay within arbitrarily chosen time-windows. We conclude that (1)H-MRS has the potential to detect the clinically relevant time of onset of ischemic stroke
Characterization of metabolically healthy obese people and metabolically unhealthy normal-weight people in a general population cohort of the ABCD Study
There is actually no consensus about the possibility that in some instances, obesity may be a benign metabolically healthy (MH) condition as opposed to a normal-weight but metabolically unhealthy (MUH) state. The aim of this study was to characterize MH condition and to investigate possible associations with metabolic and cardiovascular complications. One thousand nineteen people (range of age 18-90 years) of the cohort of the ABCD-2 study were investigated. Participants were classified as normal weight (BMI < 24.9 kg/m2) or overweight-obese (BMI \ue2\u89\ua525 kg/m2); they were also classified as MH in the presence of 0-1 among the following conditions: (a) prediabetes/type 2 diabetes, (b) hypertension, (c) hypertriglyceridemia or low HDL cholesterolemia, and (d) hypercholesterolemia. MUH condition was diagnosed if \ue2\u89\ua52 of the conditions listed were found. The prevalence of overweight/obese people was 71.1%, of whom 27.4% were found to be MH. In addition, 36.7% of the normal-weight participants were MUH. HOMA-IR, high sensitivity C-reactive protein, and the carotid intima-media thickness were significantly different in the 4 subgroups (P < 0.001), with higher values observed in the MUH normal-weight and obese groups. In conclusion, this study highlights the importance of identifying a MH condition in normal-weight and in obese people in order to offer better treatment
Electrospun PHEA-PLA/PCL Scaffold for Vascular Regeneration: A Preliminary in\ua0Vivo Evaluation
Background. There is increasing interest in the development of vessel substitutes, and many studies are currently focusing on the development of biodegradable scaffolds capable of fostering vascular regeneration. We tested a new biocompatible and biodegradable material with mechanical properties similar to those of blood vessels.
Methods. The material used comprises a mixture of a,b-poly(N-2-hydroxyethyl)-D,L-aspartamide (PHEA) and polylactic acid (PLA), combined with polycaprolactone (PCL) by means of electrospinning technique. Low-molecular-weight heparin was also linked to the copolymer. A tubular PHEA-PLA/PCL sample was used to create an arteriovenous fistula in a pig model with the use of the external iliac vessels. The flow was assessed by means of Doppler ultrasound examination weekly, and 1 month after the implantation we removed the scaffold for histopathologic evaluation.
Results. The implants showed a perfect leak-proof seal and adequate elastic tension to blood pressure. About w3 weeks after the implantation, Doppler examination revealed thrombosis of the graft, so we proceeded to its removal. Histologic examination showed chronic inflammation, with the presence of foreign body cells and marked neovascularization. The material had been largely absorbed, leaving some isolated spot residues.
Conclusions. The biocompatibility of PHEA-PLA/PCL and its physical properties make it suitable for the replacement of vessels. In the future, the possibility of functionalizing the material with a variety of molecules, to modulate the inflammatory and coagulative responses, will allow obtaining devices suitable for the replacement of native vessels
- …
