378 research outputs found
Legal Education in Transition: Trends and Their Implications
This is a pivotal moment in legal education. Revisions in American Bar Association accreditation standards, approved in August 2014, impose new requirements, including practice-based requirements, on law schools. Other external regulators and critics are pushing for significant changes too. For example, the California bar licensing body is proposing to add a practice-based, experiential requirement to its licensing requirements, and the New York Court of Appeals, New York’s highest court, is giving third-year, second semester students the opportunity to practice full-time in indigent legal services programs and projects. Unbeknown to many, there have been significant recent changes in legal education that have added practice-based courses, or practice-based components to courses, in all three years of legal education. Increasingly, law schools are reaching beyond the JD to establish projects in which graduates learn while practicing law. The innovations include first-year courses in which students engage in actual legal work to help provide legal services to clients; technology clinics in which students use or build state-of-the-art technology to help pro se litigants more effectively represent themselves; diversified experiential courses, including “practicums;” and post-JD “incubator,” “fellowship,” “residency,” “apprenticeship,” and “job corps” programs in which law graduates, and sometimes law students, practice and learn from practice. It is a dynamic period in which law schools, including through comprehensive strategic planning, should regain the leadership in facing the present and future challenges. The factors contributing to change—for example, the tough job market, reduced law school applications, interventions of regulators, U.S. News & World Report rankings and increased competition among law schools—are not likely to substantially change in the near future. Law schools are in, should be in, and will be in a period that calls for sustained innovation
Salton Sea, California
The Salton Sea, California\u27s largest lake, is located in the southeastern desert region of California. It lies within a 7851 square mile endorheic hydrologic basin that includes the Coachella and Imperial Valleys of California, and the Mexicali Valley of Mexico, with a surface elevation of 227 feet below mean sea level (msl). The shallow nature of this hypersaline lake, with a surface area of 367 square miles (951 square kilometers) and a maximum depth of 51 feet (15.5 meters), renders it very sensitive to even slight changes of inflow volume. Over 85 percent of the water entering the Salton Sea results from agricultural run-off, 1.34 million acre feet (Maf), with less than three percent of annual inflow deriving from basin precipitation. The Salton Sea is situated in the Colorado Desert in one of the most arid regions of the United States. Annual precipitation is less than 3 in. (7.6 cm), and mean monthly temperatures in July are 92°F (33.3°C), with maximum temperatures exceeding 100°F (37.7°C) on more than 110 days per annum. Potential evaporation is estimated at 5.78 feet (1.76 meters) per year.https://inspire.redlands.edu/oh_chapters/1161/thumbnail.jp
Experimental Investigation of Forces Produced by Misaligned Steel Rollers
The International Space Station (ISS) Solar Alpha Rotary Joint (SARJ) uses a roller-based mechanism for positioning of the solar arrays. The forces and moments that develop at the roller interfaces are influenced by the design including the kinematic constraints and the lubrication condition. To help understand the SARJ operation, a set of dedicated experiments were completed using roller pairs. Of primary interest was to measure the axial force directed along the axis of rotation of the roller as a function of shaft misalignment. The conditions studied included dry and clean surfaces; one surface plated by a gold film, and greased surfaces. For the case of a bare 440C roller against a nitrided 15-5 roller without lubrication, the axial force can be as great as 0.4 times the normal load for a shaft angle of 0.5 deg. Such a magnitude of force on a roller in the SARJ mechanism would cause roller tipping and contact pressures much greater than anticipated by the designers. For the case of a bare 440C roller against a nitrided 15-5 roller with grease lubrication, the axial force does not exceed about 0.15 times the normal load even for the largest misalignment angles tested. Gold films provided good lubrication for the short duration testing reported herein. Grease lubrication limited the magnitude of the axial force to even smaller magnitudes than was achieved with the gold films. The experiments demonstrate the critical role of good lubrication for the SARJ mechanism
Eutrophication
Eutrophication is a syndrome of [../152248/index.html ecosystem]] responses to human activities that fertilize water bodies with nitrogen (N) and phosphorus (P), often leading to changes in animal and plant populations and degradation of water and habitat quality. Nitrogen and phosphorus are essential components of structural proteins, enzymes, cell membranes, nucleic acids, and molecules that capture and utilize light and chemical energy to support life. The biologically available forms of N and P are present at low concentrations in pristine lakes, rivers, estuaries, and in vast regions of the upper ocean.https://inspire.redlands.edu/oh_chapters/1160/thumbnail.jp
ISS Solar Array Alpha Rotary Joint (SARJ) Bearing Failure and Recovery: Technical and Project Management Lessons Learned
The photovoltaic solar panels on the International Space Station (ISS) track the Sun through continuous rotating motion enabled by large bearings on the main truss called solar array alpha rotary joints (SARJs). In late 2007, shortly after installation, the starboard SARJ had become hard to turn and had to be shut down after exceeding drive current safety limits. The port SARJ, of the same design, had been working well for over 2 years. An exhaustive failure investigation ensued that included multiple extravehicular activities to collect information and samples for engineering forensics, detailed structural and thermal analyses, and a careful review of the build records. The ultimate root cause was determined to be kinematic design vulnerability coupled with inadequate lubrication, and manufacturing flaws; this was corroborated through ground tests, metallurgical studies, and modeling. A highly successful recovery plan was developed and implemented that included replacing worn and damaged components in orbit and applying space-compatible grease to improve lubrication. Beyond the technical aspects, however, lie several key programmatic lessons learned. These lessons, such as running ground tests to intentional failure to experimentally verify failure modes, are reviewed and discussed so they can be applied to future projects to avoid such problems
Performance of MoS2 Coated Gears Exposed to Humid Air During Storage
The purpose of this work was to study the effect of exposure to humid air on the durability of a molybdenum disulfide dry film lubricant applied to spur test gears and subsequently tested in vacuum environment. This study was motivated by the James Webb Space Telescope (JWST) Mission. Some moving mechanical assembles of the JWST have been exposed to humid air during storage as a subassembly and after integration into a higher-level assembly. molybdenum disulfide dry film lubricant was applied to steel spur test gears and subsequently tested in vacuum environment. One-half of the gears had essentially zero time exposure to humid air prior to testing, and the other half were exposed to humid air of 57 percent relative humidity for exposure durations up to 77 days prior to testing. All tests were completed at the same constant torque and speed. On average, the film durability, as measured by the number of pinion revolutions, was shorter for gears exposed to humid air compared to those with zero exposure. For the unexposed gears, the durability ranged from 53,300 to 190,300 pinion revolutions with an average value of 100,200 and a median value of 83,500 revolutions. For the exposed gears, the durability ranged from 21,000 to 84,700 pinion revolutions with an average value of 64,900 and a median value of 68,800 revolutions. Using the unexposed gears as a baseline, the exposure reduced the average durability by 35 percent and the median value of durability by 18 percent. Red-brown coloration was noted on some of the gear teeth that had been exposed to humid air. The colored regions appeared as soon as 17 days after exposure to humid air. SEM inspections showed that at least some of these colored areas included material raised above the surrounding molybdenum disulfide film
Recommended from our members
Concomitant medication use and clinical outcome of repetitive Transcranial Magnetic Stimulation (rTMS) treatment of Major Depressive Disorder.
BackgroundRepetitive Transcranial Magnetic Stimulation (rTMS) is commonly administered to Major Depressive Disorder (MDD) patients taking psychotropic medications, yet the effects on treatment outcomes remain unknown. We explored how concomitant medication use relates to clinical response to a standard course of rTMS.MethodsMedications were tabulated for 181 MDD patients who underwent a six-week rTMS treatment course. All patients received 10 Hz rTMS administered to left dorsolateral prefrontal cortex (DLPFC), with 1 Hz administered to right DLPFC in patients with inadequate response to and/or intolerance of left-sided stimulation. Primary outcomes were change in Inventory of Depressive Symptomatology Self Report (IDS-SR30) total score after 2, 4, and 6 weeks.ResultsUse of benzodiazepines was associated with less improvement at week 2, whereas use of psychostimulants was associated with greater improvement at week 2 and across 6 weeks. These effects were significant controlling for baseline variables including age, overall symptom severity, and severity of anxiety symptoms. Response rates at week 6 were lower in benzodiazepine users versus non-users (16.4% vs. 35.5%, p = 0.008), and higher in psychostimulant users versus non-users (39.2% vs. 22.0%, p = 0.02).ConclusionsConcomitant medication use may impact rTMS treatment outcome. While the differences reported here could be considered clinically significant, results were not corrected for multiple comparisons and findings should be replicated before clinicians incorporate the evidence into clinical practice. Prospective, hypothesis-based treatment studies will aid in determining causal relationships between medication treatments and outcome
Roller Testing to Mimic Damage of the ISS SARJ Ring and Durability Test to Simulate Fifteen Years of SARJ Operation Using the Damaged Surface
The International Space Station's starboard Solar Alpha Rotary Joint (SARJ) experienced a breakdown of the joint's race ring surface. The starboard SARJ mechanism was cleaned and lubricated with grease. To provide some guidance on the expected behavior of the damaged SARJ ring with continued operations, experiments were conducted using rollers and a vacuum roller test rig. The approach of the experimental work involved three main steps: (1) initiate damage using conditions representative of the SARJ with inadequate lubrication; (2) propagate the damage by operating the test rollers without lubrication; and (3) assess the durability of the roller by testing to simulate the equivalent of 15 years of SARJ operation on the damaged surface assuming adequate grease lubrication. During the rig testing, additional and/or replacement grease was introduced at regular intervals to maintain good lubrication in the rig. The damage to the nitride layer continued even after application of grease. The grease lubrication proved to be effective for limiting the value of the axial force that can be developed. Limiting the axial force on the SARJ mechanism is important since the larger the axial force the more concentrated the load pressure becomes on the blend-radius location on the SARJ roller. After the testing simulating 15 years of SARJ operations, the wear depths were the order of 0.2 mm for the nitrided 15-5 roller and the order of 0.06 mm for the mating 440C roller. Metallographic inspections were done to search for indications of impending fatigue or other fracture indications that might eventually propagate and cause structural failure. There were no indications or features found that could eventually compromise structural integrity
Developing a Bicycle Monitoring Strategy for Hennepin County: An Automated Bicycle Counting Program
Professional paper for the fulfillment of the Master of Urban and Regional Planning program
- …