10 research outputs found

    Optimal Body Temperature in Transitional Extremely Low Birth Weight Infants Using Heart Rate and Temperature as Indicators

    Get PDF
    ABSTRACT: Objective: To explore body temperature in relationship to heart rate in extremely low birth weight (ELBW) infants during their first 12 hours to help identify the ideal set point for incubator control of body temperature. Design: Within subject, multiple-case design. Setting: A tertiary neonatal intensive care unit (NICU) in North Carolina. Participants: Ten infants born at fewer than 29 weeks gestation and weighing 400 to 1,000g. Methods: Heart rate and abdominal body temperature were measured at 1-minute intervals for 12 hours. Heart rates were considered normal if they were between the 25th and 75th percentile for each infant. Results: Abdominal temperatures were low throughout the 12-hour study period (mean 35.17-36.68°C). Seven of 10 infants had significant correlations between abdominal temperature and heart rate. Heart rates above the 75th percentile were associated with low and high abdominal temperatures; heart rates less than the 25th percentile were associated with very low abdominal temperatures. The extent to which abdominal temperature was abnormally low was related to the extent to which the heart rate trended away from normal in 6 of the 10 infants. Optimal temperature control point that maximized normal heart rate observations for each infant was between 36.8°C and 37°C. Conclusions: Hypothermia was associated with abnormal heart rates in transitional ELBW infants. We suggest nurses set incubator servo between 36.8°C and 36.9°C to optimally control body temperature for ELBW infants

    A Pilot Study to Examine Maturation of Body Temperature Control in Preterm Infants

    Get PDF
    To test instrumentation and develop analytic models to use in a larger study to examine developmental trajectories of body temperature and peripheral perfusion from birth in extremely low birth weight (EBLW) infants

    Thermography as a method of acquiring competences in Physiology. Application case for hand blood flow control

    Get PDF
    5 p.The present work proposes a methodological structure as part of the learning of the circulatory system. For this, the application of thermal stress is used, by immersing the hands in cold water to visualize the reperfusion of the hands. Learning, based on the visualization and analysis of thermographic images, allows the acquisition of specific competences at the university level. In graduate studies such as physiotherapy and nursing, the use of virtual tools and materials that allow the acquisition of skills and technical knowledge is essential for the job performance of future professionals. The application of this methodology is proposed in practical sessions of subjects in the area of knowledge of Physiology, to demonstrate and facilitate the understanding of the circulatory system. This approach is framed within the discipline of virtual laboratories since the virtual materials generated can be used for the acquisition of skills and practical competencies, as well as for the evaluation of competencies in e-learning courses. In this way, by recording a pedagogical video that shows a short practice, 5 minutes long, it is possible to establish the necessary knowledge bases to expand them later. This material is easily implementable in any learning management system.S

    Cre-Dependent Expression of Multiple Transgenes in Isolated Neurons of the Adult Forebrain

    Get PDF
    Background: Transgenic mice with mosaic, Golgi-staining-like expression of enhanced green fluorescent protein (EGFP) have been very useful in studying the dynamics of neuronal structure and function. In order to further investigate the molecular events regulating structural plasticity, it would be useful to express multiple proteins in the same sparse neurons, allowing co-expression of functional proteins or co-labeling of subcellular compartments with other fluorescent proteins. However, it has been difficult to obtain reproducible expression in the same subset of neurons for direct comparison of neurons expressing different functional proteins. Principal Findings: Here we describe a Cre-transgenic line that allows reproducible expression of transgenic proteins of choice in a small number of neurons of the adult cortex, hippocampus, striatum, olfactory bulb, subiculum, hypothalamus, superior colliculus and amygdala. We show that using these Cre-transgenic mice, multiple Cre-dependent transgenes can be expressed together in the same isolated neurons. We also describe a Cre-dependent transgenic line expressing a membrane associated EGFP (EGFP-F). Crossed with the Cre-transgenic line, EGFP-F expression starts in the adolescent forebrain, is present in dendrites, dendritic protrusions, axons and boutons and is strong enough for acute or chronic in vivo imaging. Significance: This triple transgenic approach will aid the morphological and functional characterization of neurons in various Cre-dependent transgenic mice

    A Pilot Study to Examine Maturation of Body Temperature Control in Preterm Infants

    No full text
    OBJECTIVE: To test instrumentation and develop analytic models to use in a larger study to examine developmental trajectories of body temperature and peripheral perfusion from birth in extremely low birth weight (EBLW) infants. DESIGN: A case study design. SETTING: The study took place in a level four neonatal intensive care unit (NICU) in North Carolina. PARTICIPANTS: Four ELBW infants, less than 29 weeks gestational age at birth. METHODS: Physiologic data were measured every minute for the first 5 days of life: peripheral perfusion using perfusion index by Masimo and body temperature using thermistors. Body temperature was also measured using infrared thermal imaging. Stimulation and care events were recorded over the first 5 days using video which was coded with Noldus Observer software. Novel analytical models using the state space approach to time series analysis were developed to explore maturation of neural control over central and peripheral body temperature. RESULTS/CONCLUSION: Results from this pilot study confirmed the feasibility of using multiple instruments to measure temperature and perfusion in ELBW infants. This approach added rich data to our case study design and set a clinical context with which to interpret longitudinal physiological data

    Literacy, literacies, and the digital in higher education

    No full text
    This paper is a critical review of some recent literature around the "literacies of the digital" in Schools and Higher Education. It discusses the question: 'what does the conjoining of the terms "digital" and "literacy" add to our understanding of teaching and learning in higher education'? It explores the continuing role of critical literacy in relation to the idea that digital literacies are transformative for pedagogy in this sector

    Identification of a seven glycopeptide signature for malignant pleural mesothelioma in human serum by selected reaction monitoring

    Get PDF
    BACKGROUND Serum biomarkers can improve diagnosis and treatment of malignant pleural mesothelioma (MPM). However, the evaluation of potential new serum biomarker candidates is hampered by a lack of assay technologies for their clinical evaluation. Here we followed a hypothesis-driven targeted proteomics strategy for the identification and clinical evaluation of MPM candidate biomarkers in serum of patient cohorts. RESULTS Based on the hypothesis that cell surface exposed glycoproteins are prone to be released from tumor-cells to the circulatory system, we screened the surfaceome of model cell lines for potential MPM candidate biomarkers. Selected Reaction Monitoring (SRM) assay technology allowed for the direct evaluation of the newly identified candidates in serum. Our evaluation of 51 candidate biomarkers in the context of a training and an independent validation set revealed a reproducible glycopeptide signature of MPM in serum which complemented the MPM biomarker mesothelin. CONCLUSIONS Our study shows that SRM assay technology enables the direct clinical evaluation of protein-derived candidate biomarker panels for which clinically reliable ELISA's currently do not exist
    corecore