5 research outputs found

    Evaluation of stress distribution on an endodontically treated maxillary central tooth with lesion restored with different crown materials : A finite element analysis

    Get PDF
    Objectives: The biomechanical response of teeth with periapical lesions that have been restored using various substructure materials, as well as the stress mapping in the alveolar bone, has not been thoroughly described. In this context, the objective of this study is to investigate the structural stress distributions on root canal-treated maxillary right central incisors with lesions restored using different crown materials under linear static loading conditions through finite element analysis (FEA). Methods: In the study, five FEA models were utilised to represent healthy teeth and teeth restored with different substructure materials: (A) a healthy tooth, (B) a lesioned, root canal-treated, composite-filled tooth, (C) a lesioned, fiber-posted, zirconia-based crown, (D) a tooth with lesions, a fiber post, and Ni–Cr infrastructure crown, (E) a tooth with a lesion, a fiber post, and an IPS E-max infrastructure crown. A force of 100 N was applied at an angle of 45◦ to the long axis of the tooth from 2 mm cervical to the incisal line on the palatal surface. Deformation behaviour and maximum equivalent stress distributions on the tooth sub-components, including the bony structure for each model, were simulated. Results: Differences were observed in the stress distributions of the models. The maximum stress values of the models representing the restorations with different infrastructures varied, and the highest value was obtained in the model of the E-max crown (Model E: 136.050 MPa). The minimum stress magnitudes were obtained from Model B the composite-filled tooth (80.39 MPa); however, it was observed that the equivalent stresses in all the models showed a similar distribution for all components with varying magnitudes. In periapical lesion areas, low stresses were observed. In all models, the cervicobuccal collar region of the teeth had dense equivalent stresses. Conclusion: Different restorative treatment methods applied to root canal-treated teeth with periapical lesions can impact the stress in the alveolar bone and the biomechanical response of the tooth. Relatively high stress values in the cortical bone at the cervical line of the tooth have been observed to decrease towards the apical region. This observation may suggest a potential healing effect by reducing pressure in the periapical lesion area. Clinical significance: Composite resin restorations can be considered the first-choice treatment option for the restoration of root canal-treated teeth with lesions. In crown restorations, it would be advantageous to prefer zirconia or metal-supported prostheses in terms of biomechanics

    Mental Foramenin Lokalizasyonun Radyografik Olarak Değerlendirilmesi

    Get PDF
    Amaç: Mental foramenin yerinin tam olarak lokalize edilmesi alt çeneye uygulanan cerrahi operasyonlar açısından kritik bir öneme sahiptir. Lokalizasyonunun çeşitliliği özellikle implant cerrahisi gibi bazı operasyonlar sırasında komplikasyona sebep olabilir. Bu çalışmanın amacı Sivas ilindeki hastalardan elde edilen dijital panoramik röntgenleri değerlendirerek, mental foramenin lokalizasyonunu araştırmaktır. Gereç ve yöntem: Bu çalışmada, 360 hastanın dijital panoramik röntgeni retrospektif olarak incelenmiştir. Panoramik röntgenlerde, mental foramenin farklı lokalizasyonları cinsiyet ayrımı gözeterek, simetrik ve asimetrik olarak değerlendirilmiştir. Ayrıca mental foramenin alveoler kret tepesine ve alt çene alt kenarına olan ortalama uzaklıkları incelenmiştir. Bulgular: Mental foramen hastaların % 59,4’ünde birinci ve ikinci küçük azı dişleri arasında ,% 37,2’sinde ikinci küçük azı diş aksının hizasında olduğu belirlendi. Erkeklerin % 64,6’sında ve kadınların % 55,1’ninde mental foramenin birinci ve ikinci küçük azı dişleri arasında olduğu bulundu. Mental foramenin hastaların % 80,3’ünde simetrik olduğu saptandı. Mental foramenin sağ tarafta alveoler kret tepesine 16,79 mm ve alt çene alt kenarına 12,46 mm ortalama uzaklıkta olduğu belirlendi. Sol tarafta ise foramenin alveoler kret tepesine 16,80 mm alt çene alt kenarına 12,58 mm ortalama uzaklıkta olduğu bulundu. Sonuç: Sonuç olarak, panoramik radyografide Sivas il genelinde mental foramenin en sık olarak birinci ve ikinci küçük azı dişleri arasında lokalize olduklar ve diğer pozisyonlarda lokalizasyonlarının ise çok düşük olduğu görülmüştür. Vakaların çoğunda bilateral olarak simetrik olduğu görülmüştür

    Evaluation of Efficacy of Various Surface Conditioning Methods on the Repair Bond Strength of Composite to Different Fracture Types of Zirconia Ceramics

    No full text
    The aim of this study was to investigate the effects of different surface treatment methods on shear bond strength between composite resin and different levels of zirconia ceramic. Laser surface-conditioning procedures have been reported as effective method to increase repair bond strength of composite to zirconia ceramics. Detailed information of effects of Er,Cr:YSGG laser treatment with different pulse rates on the zirconia ceramics is lacking in the literature. 120 disc-shaped specimens were prepared including zirconia, veneering ceramic, and 50% veneering ceramic-50% zirconia surfaces. Four different surface treatments were applied to the specimens. These were grinding with diamond bur, sandblasting, and short and long pulse rates of Er,Cr:YSGG laser irradiation. An intraoral ceramic repair kit was used to repair specimens, and shear bond strength was performed on the composite resin to each specimen. The highest mean bond strength was seen in the veneering ceramic surface that was ground using a diamond bur, and the lowest mean bond strength value was observed in the same surface that was treated with long pulse laser irradiation. The sandblasting with alumina particles exhibited lower mean repairing bond strength among the rest of used methods in this study for the group which contained half of the veneering ceramic and half of the zirconia. Sandblasting and Er,Cr:YSGG laser using surface treatment procedures obtained appropriate bond strength for the group that included 50% veneering ceramic-50% zirconia, because of no significant differences observed among the applied surface conditioning methods in this group

    Mental Foramenin Lokalizasyonun Radyografik Olarak Değerlendirilmesi

    No full text
    <span style="line-height: 115%; font-family: "Times New Roman","serif"; letter-spacing: -0.3pt; color: black; font-size: 9pt; mso-fareast-font-family: Calibri; mso-ansi-language: TR; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;"><strong>Amaç: </strong></span><span style="line-height: 115%; font-family: "Times New Roman","serif"; letter-spacing: -0.3pt; color: black; font-size: 9pt; mso-fareast-font-family: Calibri; mso-ansi-language: TR; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">Mental foramenin yerinin tam olarak lokalize edilmesi alt çeneye uygulanan cerrahi operasyonlar açısından kritik bir öneme sahiptir. Lokalizasyonunun çeşitliliği özellikle implant cerrahisi gibi bazı operasyonlar sırasında komplikasyona sebep olabilir.<span style="mso-bidi-font-style: italic;"> Bu çalışmanın amacı Sivas ilindeki hastalardan elde edilen dijital panoramik röntgenleri değerlendirerek, mental foramenin lokalizasyonunu araştırmaktır. </span></span><strong style="mso-bidi-font-weight: normal;"><span style="line-height: 115%; font-family: "Times New Roman","serif"; color: black; font-size: 9pt; mso-fareast-font-family: Calibri; mso-ansi-language: TR; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">Gereç ve yöntem: </span></strong><span style="line-height: 115%; font-family: "Times New Roman","serif"; color: black; font-size: 9pt; mso-fareast-font-family: Calibri; mso-ansi-language: TR; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">Bu çalışmada, 360 hastanın dijital panoramik röntgeni retrospektif olarak incelenmiştir. Panoramik röntgenlerde, mental foramenin farklı lokalizasyonları cinsiyet ayrımı gözeterek, simetrik ve asimetrik olarak değerlendirilmiştir. Ayrıca mental foramenin alveoler kret tepesine ve alt çene alt kenarına olan ortalama uzaklıkları incelenmiştir. <strong style="mso-bidi-font-weight: normal;">Bulgular: </strong>Mental foramen hastaların % 59,4’ünde birinci ve ikinci küçük azı dişleri arasında ,% 37,2’sinde ikinci küçük azı diş aksının hizasında olduğu belirlendi. Erkeklerin % 64,6’sında ve kadınların % 55,1’ninde mental foramenin birinci ve ikinci küçük azı dişleri arasında olduğu bulundu. Mental foramenin hastaların % 80,3’ünde simetrik olduğu saptandı. Mental foramenin sağ tarafta alveoler kret tepesine 16,79 mm ve alt çene alt kenarına 12,46 mm ortalama uzaklıkta olduğu belirlendi. Sol tarafta ise foramenin alveoler kret tepesine 16,80 mm alt çene alt kenarına 12,58 mm ortalama uzaklıkta olduğu bulundu. <strong style="mso-bidi-font-weight: normal;">Sonuç:</strong><span style="mso-bidi-font-style: italic;"><span style="mso-spacerun: yes;"> </span></span><a name="OLE_LINK4"></a><a name="OLE_LINK3"><span style="mso-bookmark: OLE_LINK4;">Sonuç olarak, panoramik radyografide Sivas il genelinde mental foramenin en sık olarak birinci ve ikinci küçük azı dişleri arasında lokalize olduklar ve diğer pozisyonlarda lokalizasyonlarının ise çok düşük olduğu görülmüştür. Vakaların çoğunda bilateral olarak simetrik olduğu görülmüştür. </span></a></span&gt
    corecore