636 research outputs found

    CT Evidence for Subchondral Trabecular Injury of the Femoral Head in Transient Osteoporosis of the Hip: A Case Report

    Get PDF
    A 28-yr-old woman presented with both hip pain that started sequentially during the peripartum period. Diagnosis of transient osteoporosis of the hip (TOH) was made based on typical findings of plain radiographs and magnetic resonance images. The subchondral trabeculae of the femoral head were evaluated on serially taken coronal multiplanar reformation computerized tomogram images. At 4 weeks after pain onset, marked decrease in the sclerotic density with irregular discontinuation was observed in the primary compression trabeculae. At 12 weeks, a focal area of irregular thickening of trabeculae was observed. At 20 weeks, sclerotic density of trabeculae recovered markedly and the focal area of irregular trabecular thickening disappeared. At 1 yr, subchondral trabeculae recovered almost completely. The evidence of subchondral trabecular injury was observed in the femoral heads of TOH

    Far-Ultraviolet Cooling Features of the Antlia Supernova Remnant

    Full text link
    We present far-ultraviolet observations of the Antlia supernova remnant obtained with Far-ultraviolet IMaging Spectrograph (FIMS, also called SPEAR). The strongest lines observed are C IV 1548,1551 and C III 977. The C IV emission of this mixed-morphology supernova remnant shows a clumpy distribution, and the line intensity is nearly constant with radius. The C III 977 line, though too weak to be mapped over the whole remnant, is shown to vary radially. The line intensity peaks at about half the radius, and drops at the edge of the remnant. Both the clumpy distribution of C IV and the rise in the C IV to C III ratio towards the edge suggest that central emission is from evaporating cloudlets rather than thermal conduction in a more uniform, dense medium.Comment: 9 pages, 4 figures, will be published in ApJ December 1, 2007, v670n2 issue. see http://astro.snu.ac.kr/~jhshinn/ms.pd

    Temperature Driven Structural Phase Transition in Tetragonal-Like BiFeO3

    Full text link
    Highly-strained BiFeO3 exhibits a "tetragonal-like, monoclinic" crystal structure found only in epitaxial films (with an out-of-plane lattice parameter exceeding the in-plane value by >20%). Previous work has shown that this phase is properly described as a MC_{C} monoclinic structure at room temperature [with a (010)pc_{pc} symmetry plane, which contains the ferroelectric polarization]. Here we show detailed temperature-dependent x-ray diffraction data that evidence a structural phase transition at ~100C to a high-temperature MA_{A} phase ["tetragonal-like" but with a (1-10)pc_{pc} symmetry plane]. These results indicate that the ferroelectric properties and domain structures of strained BiFeO3_3 will be strongly temperature dependent.Comment: 10 pages, 3 figure

    Properties of oriented strand board made from Betung bamboo (Dendrocalamus asper (Schultes.f) Backer ex Heyne)

    Get PDF
    Bamboo has gained increasing attention as an alternative raw material for use in the manufacture of composite boards. Three-layer OSBs were made using Betung bamboo (Dendrocalamus asper (Schultes.f) Backer ex Heyne) strands to evaluate the effects of strand length and pre-treatment techniques on the physical, mechanical, and durability properties. Three different strand lengths, namely 50, 60, and 70 mm, were prepared. Prior to the manufacture into OSB, the strands were immersed in cold water for 24 h and in 6% acetic anhydrides solution for 48 h. The OSBs were fabricated using 5% MDI resin based on the strand dry weight. The results indicated that MOR and MOE values in perpendicular to the grain direction were much influenced by strand length. The dimensional stability of OSB was slightly improved by immersing the strands in acetic anhydride solution. Immersing strands in cold water and acetic anhydride solution improved the resistance of OSB against subterranean termite (Macrotermes gylvus) attack under the adopted experimental condition. All OSB parameters manufactured in this experiment were better than the minimum requirement of CSA 0437.0 (Grade O–2) standard

    The role of adjuvant pelvic radiotherapy in rectal cancer with synchronous liver metastasis: a retrospective study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Synchronous liver metastases are detected in approximately 25% of colorectal cancer patients at diagnosis. The rates of local failure and distant metastasis are substantial in these patients, even after undergoing aggressive treatments including resection of primary and metastatic liver tumors. The purpose of this study was to determine whether adjuvant pelvic radiotherapy is beneficial for pelvic control and overall survival in rectal cancer patients with synchronous liver metastasis after primary tumor resection.</p> <p>Methods</p> <p>Among rectal cancer patients who received total mesorectal excision (TME) between 1997 and 2006 at Yonsei University Health System, eighty-nine patients diagnosed with synchronous liver metastasis were reviewed. Twenty-seven patients received adjuvant pelvic RT (group S + R), and sixty-two patients were managed without RT (group S). Thirty-six patients (58%) in group S and twenty patients (74%) in group S+R received local treatment for liver metastasis. Failure patterns and survival outcomes were analyzed.</p> <p>Results</p> <p>Pelvic failure was observed in twenty-five patients; twenty-one patients in group S (34%), and four patients in group S+R (15%) (<it>p </it>= 0.066). The two-year pelvic failure-free survival rates (PFFS) of group S and group S+R were 64.8% and 80.8% (<it>p </it>= 0.028), respectively, and the two-year overall survival rates (OS) were 49.1% and 70.4% (<it>p </it>= 0.116), respectively. In a subgroup analysis of fifty-six patients who received local treatment for liver metastasis, the two-year PFFS were 64.9% and 82.9% (<it>p </it>= 0.05), respectively; the two-year OS were 74.1% and 80.0% (<it>p </it>= 0.616) in group S (n = 36) and group S+R (n = 20), respectively.</p> <p>Conclusions</p> <p>Adjuvant pelvic RT significantly reduced the pelvic failure rate but its influence on overall survival was unclear. Rectal cancer patients with synchronous liver metastasis may benefit from adjuvant pelvic RT through an increased pelvic control rate and improved quality of life.</p

    Transcription Factor Sp1 Is Involved in Expressional Regulation of Coxsackie and Adenovirus Receptor in Cancer Cells

    Get PDF
    Coxsackie and adenovirus receptor (CAR) was first known as a virus receptor. Recently, it is also known to have tumor suppressive activity such as inhibition of cell proliferation, migration, and invasion. It is important to understand how CAR expression can be regulated in cancers. Based on an existence of putative Sp1 binding site within CAR promoter, we investigated whether indeed Sp1 is involved in the regulation of CAR expression. We observed that deletion or mutation of Sp1 binding motif (−503/−498) prominently impaired the Sp1 binding affinity and activity of CAR promoter. Histone deacetylase inhibitor (TSA) treatment enhanced recruitment of Sp1 to the CAR promoter in ChIP assay. Meanwhile, Sp1 binding inhibitor suppressed the recruitment. Exogenous expression of wild-type Sp1 increased CAR expression in CAR-negative cells; meanwhile, dominant negative Sp1 decreased the CAR expression in CAR-positive cells. These results indicate that Sp1 is involved in regulation of CAR expression

    Fabrication of pyramidal probes with various periodic patterns and a single nanopore

    Get PDF
    The nanometer-scale patterned pyramidal probe with an electron beam-induced nanopore on the pyramid apex is an excellent candidate for an optical biosensor. The nanoapertures surrounded with various periodic groove patterns on the pyramid sides were fabricated using a focused ion beam technique, where the optical characteristics of the fabricated apertures with rectangular, circular, and elliptical groove patterns were investigated. The elliptical groove patterns on the pyramid were designed to maintain an identical distance between the grooves and the apex for the surface waves and, among the three patterns, the authors observed the highest optical transmission from the elliptically patterned pyramidal probe. A 103-fold increase of the transmitted optical intensity was observed after patterning with elliptical grooves, even without an aperture on the pyramid apex. The nanopore on the apex of the pyramid was fabricated using electron beam irradiation and was optically characterized
    corecore