266,651 research outputs found

    Pulsar Velocity with Three-Neutrino Oscillations in Non-adiabatic Processes

    Full text link
    We have studied the position dependence of neutrino energy on the Kusenko-Segr\`{e} mechanism as an explanation of the proper motion of pulsars. The mechanism is also examined in three-generation mixing of neutrinos and in a non-adiabatic case. The position dependence of neutrino energy requires the higher value of magnetic field such as B∌3×1015B\sim 3\times 10^{15} Gauss in order to explain the observed proper motion of pulsars. It is shown that possible non-adiabatic processes decrease the neutrino momentum asymmetry, whereas an excess of electron neutrino flux over other flavor neutrino fluxes increases the neutrino momentum asymmetry. It is also shown that a general treatment with all three neutrinos does not modify the result of the two generation treatment if the standard neutrino mass hierarchy is assumed.Comment: 8 pages, REVTEX, no figure

    Axial Anomaly and the Nucleon Spin

    Get PDF
    In this letter, we have taken a particular Lagrangian, which was introduced to resolve U(1) problem, as an effective QCD Lagrangian, and have derived a formula of the quark content of the nucleon spin. The difference between quark content of the proton (\Delta\Sigma_p) and that of the neutron (\Delta\Sigma_n) is evaluated by this formula. Neglecting the higher-order isospin corrections, this formula can reduce to Efremov's results in the large N_c limit.Comment: (1) A few changes and corrections made following Referee. (2) The difference between quark content of the proton (\Delta\Sigma_p) and that of the neutron (\Delta\Sigma_n) is evaluated. Neglecting the higher-order isospin corrections, this formula can reduce to Efremov's results in the large N_c limi

    Monitoring Frequency of Intra‐Fraction Patient Motion Using the ExacTrac System for LINAC‐based SRS Treatments

    Get PDF
    Purpose: The aim of this study was to investigate the intra‐fractional patient motion using the ExacTrac system in LINAC‐based stereotactic radiosurgery (SRS). Method: A retrospective analysis of 104 SRS patients with kilovoltage image‐guided setup (Brainlab ExacTrac) data was performed. Each patient was imaged pre‐treatment, and at two time points during treatment (1st and 2nd mid‐treatment), and bony anatomy of the skull was used to establish setup error at each time point. The datasets included the translational and rotational setup error, as well as the time period between image acquisitions. After each image acquisition, the patient was repositioned using the calculated shift to correct the setup error. Only translational errors were corrected due to the absence of a 6D treatment table. Setup time and directional shift values were analyzed to determine correlation between shift magnitudes as well as time between acquisitions. Results: The average magnitude translation was 0.64 ± 0.59 mm, 0.79 ± 0.45 mm, and 0.65 ± 0.35 mm for the pre‐treatment, 1st mid‐treatment, and 2nd mid‐treatment imaging time points. The average time from pre‐treatment image acquisition to 1st mid‐treatment image acquisition was 7.98 ± 0.45 min, from 1st to 2nd mid‐treatment image was 4.87 ± 1.96 min. The greatest translation was 3.64 mm, occurring in the pre‐treatment image. No patient had a 1st or 2nd mid‐treatment image with greater than 2 mm magnitude shifts. Conclusion: There was no correlation between patient motion over time, in direction or magnitude, and duration of treatment. The imaging frequency could be reduced to decrease imaging dose and treatment time without significant changes in patient position
    • 

    corecore