1,179 research outputs found

    Full-field pulsed magneto-photoelasticity – Experimental Implementation

    No full text
    This paper contains a description of the experimental procedure employed when using a pulsed-magneto-polariscope (PMP) and some initial full-field through-thickness measurements of the stress distribution present in samples containing 3D stresses. The instrument uses the theory of magneto-photoelasticity (MPE), which is an experimental stress analysis technique that involves the application of a magnetic field to a birefringent model within a polariscope. MPE was developed for through-thickness stress measurement where the integrated through-thickness birefringent measurement disguises the actual stress distribution. MPE is mainly used in toughened glass where the through-thickness distribution can reduce its overall strength and so its determination is important. To date MPE has been a single-point 2D through-thickness measurement and the analysis time is prohibitive for the investigation of an area which may contain high localised stresses. The pulsed-magneto-polariscope (PMP) has been designed to enable the application of full-field 3D MPE [ ]. Using a proof-of concept PMP several experimental measurements were made, these were promising and demonstrate the potential of the new instrument. Further development of this technique presents several exciting possibilities including a tool for the measurement of the distribution of principal stress difference seen in a general 3D model

    Value of Combination of Standard Axial and Thin-Section Coronal Diffusion-weighted Imaging in Diagnosis of Acute Brainstem Infarction

    Get PDF
    AIM: To determine the value of the combination of thin-section 3 mm ‎coronal and standard ‎axial DWI and their impact in facilitating the diagnosis of ‎‎acute brainstem infarction. METHODS: A cross-sectional study conducted from the 1st of April 2017 to the end of February 2018 on 100 consecutive patients (66% were male, and 34% were female) with isolated acute ischemic infarction in the ‎brainstem. The abnormal MRI findings concerning the ischemic lesions were interpreted on standard axial 5 mm and thin-section coronal 3mm DWI. RESULTS: The mean age of the studied group was 69.2 ± 4.3 for male and 72.3 ± 2.5 years. The standard axial DWI can diagnose 20%, 6.7% and 6.7% of the infarctions in midbrain, pons and medulla oblongata respectively, while both axial and thin coronal sections together can diagnose 80% of midbrain infarctions, 93.3% of pons infarctions and 93.3% of medulla oblongata infarctions. Furthermore, the thin section coronal 3 mm section can diagnose very smaller ischemic lesion volume in comparison to the standard axial 5mm section (3.4 ± 0.45 / cm3 versus 4.6 ± 0.23 / cm3, P < 0.001) CONCLUSION: The addition of thin-section coronal DWI can facilitate the detection of brainstem ischemic lesions. We suggest its inclusion in the stroke MRI protocol

    A New Generalization of the Lomax Distribution with Increasing, Decreasing, and Constant Failure Rate

    Get PDF
    Developing new compound distributions which are more flexible than the existing distributions have become the new trend in distribution theory. In this present study, the Lomax distribution was extended using the Gompertz family of distribution, its resulting densities and statistical properties were carefully derived, and the method of maximum likelihood estimation was proposed in estimating themodel parameters. A simulation study to assess the performance of the parameters of Gompertz Lomax distribution was provided and an application to real life data was provided to assess the potentials of the newly derived distribution. Excerpt from the analysis indicates that the Gompertz Lomax distribution performed better than the Beta Lomax distribution, Weibull Lomax distribution, and Kumaraswamy Lomax distribution

    The Reliability of Red Flags in Spinal Cord Compression

    Get PDF
    Background: Acute low back pain is a common cause for presentation to the emergency department (ED). Since benign etiologies account for 95% of cases, red flags are used to identify sinister causes that require prompt management. Objectives: We assessed the effectiveness of red flag signs used in the ED to identify spinal cord and cauda equine compression. Patients and Methods: It was a retrospective cohort study of 206 patients with acute back pain admitted from the ED. The presence or absence of the red flag symptoms was assessed against evidence of spinal cord or cauda equina compression on magnetic resonance imaging (MRI). Results: Overall, 32 (15.5%) patients had compression on MRI. Profound lower limb neurologic examination did not demonstrate a statistically significant association with this finding. The likelihood ratio (LR) for bowel and bladder dysfunction (sensitivity of 0.65 and specificity of 0.73) was 2.45. Saddle sensory disturbance (sensitivity of 0.27 and specificity of 0.87) had a LR of 2.11. When both symptoms were taken together (sensitivity of 0.27 and specificity of 0.92), they gave a LR of 3.46. Conclusions: The predictive value of the two statistically significant red flags only marginally raises the clinical suspicion of spinal cord or cauda equina compression. Effective risk stratification of patients presenting to the ED with acute back pain is crucial; however, this study did not support the use of these red flags in their current form

    Estimation of noise in gray-scale and colored images using median absolute deviation (MAD)

    Get PDF
    This paper presents a new algorithm for estimation of noise (i.e., level of noise) in both gray-scale and color images (GSI, CI). The new technique is called median-absolute deviation (MAD). This technique does require an explicit estimation of the noise level or the signal to noise ratio (SNR), which is usually needed in most of the popular enhancement methods. Performance of the proposed method is evaluated on noisy images in real conditions and with artificial noise

    Practical Investigation of Effectiveness of Direct Solar-Powered Air Heater

    Full text link
    Solar energy is clean and available, and its use doesn\u27t hurt the environment. Heating conditioned homes and offices in wintertime deduct a large part of the amount of fuel consumed for these purposes. The use of solar radiation to heat the air proved its feasibility and usefulness and is in the research and development process and takes many forms. One of the primary types of solar air heaters is solar air heater of a transparent collector. In this study, a transparent collector solar air heater was designed and manufactured with an area of 1 m2. An aluminum plate was used to be the heating source; it takes its heat from the solar radiation. The tests results confirm the validity of this solar air heater type. The temperature of the heated air increased about 101% of the ambient air. The aluminum plate has proven to work as a source of heat

    ANURIA SECONDARY TO HOT WEATHER-INDUCED HYPERURICAEMIA: DIAGNOSIS AND MANAGEMENT

    Get PDF
    There is little information on the management of anuria secondary to severe volume depletion or as a rare manifestation of heat stroke in areas of the world with very hot summers. We present our experience with hot weather-induced hyperuricaemia in Kuwait

    High Security and Capacity of Image Steganography for Hiding Human Speech Based on Spatial and Cepstral Domains

    Get PDF
    A new technique of hiding a speech signal clip inside a digital color image is proposed in this paper to improve steganography security and loading capacity. The suggested technique of image steganography is achieved using both spatial and cepstral domains, where the Mel-frequency cepstral coefficients (MFCCs) are adopted, as very efficient features of the speech signal. The presented technique in this paper contributes to improving the image steganography features through two approaches. First is to support the hiding capacity by the usage of the extracted MFCCs features and pitches extracted from the speech signal and embed them inside the cover color image rather than directly hiding the whole samples of the digitized speech signal. Second is to improve the data security by hiding the secret data (MFCCs features) anywhere in the host image rather than directly using the least significant bits substitution of the cover image. At the recovering side, the proposed approach recovers these hidden features and using them to reconstruct the speech waveform again by inverting the steps of MFCCs extraction to recover an approximated vocal tract response and combine it with recovered pitch based excitation signal. The results show a peak signal to noise ratio of 52.4 dB of the stego-image, which reflect a very good quality and a reduction ratio of embedded data to about (6%–25%). In addition, the results show a speech reconstruction degree of about 94.24% correlation with the original speech signal
    corecore