38 research outputs found

    Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO). In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level.</p> <p>Methods</p> <p>Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). The melatonin levels were analyzed in duplicate using commercially available ELISA kits.</p> <p>Results</p> <p>The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL). The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level (<6 pg/mL), although the BA plots didn't show proportional and relative biases, there was no significant correlation between passive and cotton saliva collection samples.</p> <p>Conclusion</p> <p>Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.</p

    Estimating the Affection of the Exhibition Space by an Indirect Method

    No full text

    Relativity between a Component of Space and an Evaluation Method and Result

    No full text

    Review on the application of physiological and biomechanical measurement methods in driving fatigue detection

    Get PDF
    Previous studies have identified driving fatigue as the main cause of road traffic accidents, therefore, the aim of this literature review is to explore the characteristics of driving fatigue both physically and mentally as well as to explore the technology available to measure the process of fatigue physiologically. We performed e-searching in the field of fatigue detection methods through keywords tracking. The instruments studied have their own strength and weakness, and some are intrusive while the others are non-intrusive. The accuracy and stability of measurements are also varied between those instruments. In order to create more reliable fatigue detection methods, it is necessary to involve more instruments with an inter-disciplinary approach. Our intention is to make this study as a stepping stone for a more comprehensive in-vehicle real-time man-machine interaction study. Such study will not only be useful to prevent traffic accidents but also to bridge man and machine communication in the vehicle control along with developing newer technology in the field of vehicle automation

    Subadditive responses to extremely short blue and green pulsed light on visual evoked potentials, pupillary constriction and electroretinograms

    No full text
    Abstract Background The simultaneous exposure to blue and green light was reported to result in less melatonin suppression than monochromatic exposure to blue or green light. Here, we conducted an experiment using extremely short blue- and green-pulsed light to examine their visual and nonvisual effects on visual evoked potentials (VEPs), pupillary constriction, electroretinograms (ERGs), and subjective evaluations. Methods Twelve adult male subjects were exposed to three light conditions: blue-pulsed light (2.5-ms pulse width), green-pulsed light (2.5-ms pulse width), and simultaneous blue- and green-pulsed light with white background light. We measured the subject’s pupil diameter three times in each condition. Then, after 10 min of rest, the subject was exposed to the same three light conditions. We measured the averaged ERG and VEP during 210 pulsed-light exposures in each condition. We also determined subjective evaluations using a visual analog scale (VAS) method. Results The pupillary constriction during the simultaneous exposure to blue- and green-pulsed light was significantly lower than that during the blue-pulsed light exposure despite the double irradiance intensity of the combination. We also found that the b/|a| wave of the ERGs during the simultaneous exposure to blue- and green-pulsed light was lower than that during the blue-pulsed light exposure. We confirmed the subadditive response to pulsed light on pupillary constriction and ERG. However, the P100 of the VEPs during the blue-pulsed light were smaller than those during the simultaneous blue- and green-pulsed light and green-pulsed light, indicating that the P100 amplitude might depend on the luminance of light. Conclusions Our findings demonstrated the effect of the subadditive response to extremely short pulsed light on pupillary constriction and ERG responses. The effects on ipRGCs by the blue-pulsed light exposure are apparently reduced by the simultaneous irradiation of green light. The blue versus yellow (b/y) bipolar cells in the retina might be responsible for this phenomenon

    Correction to: Effect of simultaneous exposure to extremely short pulses of blue and green light on human pupillary constriction

    No full text
    Following publication of the original article [1], the authors reported that the abstract was missing from this article

    Human pupillary light reflex during successive irradiation with 1-ms blue- and green-pulsed light

    No full text
    Abstract Background In the human retina, the contribution of intrinsically photosensitive retinal ganglion cells (ipRGCs) to the regulation of the pupillary response remains poorly understood. The objective of the current study was to determine the response dynamics of the pupillary light reflex to short, successive pulses of light. In order to better assess the roles of ipRGCs and cones, we used pulses of blue and green light. Methods Each participant was exposed to 1-ms blue (466 nm) and/or green (527 nm) light pulses simultaneously or separately, with inter-stimulus intervals (ISIs) of 0, 250, 500, 750, or 1000 ms. Pupil diameter was measured using an infrared camera system. Results We found that human pupillary light responses during simultaneous irradiation or successive irradiation with ISIs ≤ 250 ms were equivalent, though successive irradiation of blue- and green-pulsed light with ISIs ≥ 500 ms induced markedly increased pupillary constriction. Conclusions We propose that this result may be related to cell hyperpolarization that occurs in the retina just after the first light stimulus is turned off, with the threshold for this effect being between 250 and 500 ms in the human retina
    corecore