3 research outputs found

    Steering Away from Current Amoxicillin Dose Reductions in Hospitalized Patients with Impaired Kidney Function to Avoid Subtherapeutic Drug Exposure.

    Get PDF
    Current dose reductions recommended for amoxicillin in patients with impaired kidney function could lead to suboptimal treatments. In a prospective, observational study in hospitalized adults with varying kidney function treated with an IV or oral dose of amoxicillin, amoxicillin concentrations were measured in 1-2 samples on the second day of treatment. Pharmacometric modelling and simulations were performed to evaluate the probability of target attainment (PTA) for 40% of the time above MIC following standard (1000 mg q6h), reduced or increased IV dosing strategies. A total of 210 amoxicillin samples was collected from 155 patients with kidney function based on a CKD-EPI of between 12 and 165 mL/min/1.73 m2. Amoxicillin clearance could be well predicted with body weight and CKD-EPI. Recommended dose adjustments resulted in a clinically relevant reduction in the PTA for the nonspecies-related PK/PD breakpoint MIC of 8 mg/L (92%, 62% and 38% with a CKD-EPI of 10, 20 and 30 mL/min/1.73 m2, respectively, versus 100% for the standard dose). For MICs ≤ 2 mg/L, PTA > 90% was reached in these patients following both reduced and standard dose regimens. Our study showed that for amoxicillin, recommended dose reductions with impaired kidney function could lead to subtherapeutic amoxicillin concentrations in hospitalized patients, especially when targeting less susceptible pathogens

    Liquid chromatography-high resolution mass spectrometry for broad-spectrum drug screening of dried blood spot as microsampling procedure.

    Get PDF
    Hyphenation of liquid chromatography (LC) with high-resolution mass spectrometry (HRMS) offers the potential to develop broad-spectrum screening procedures from low volumes of biological matrices. In parallel, dried blood spot (DBS) has become a valuable tool in the bioanalysis landscape to overcome conventional blood collection issues. Herein, we demonstrated the applicability of DBS as micro-sampling procedure for broad-spectrum toxicological screening. A method was developed on a HRMS system in data dependant acquisition (DDA) mode using an extensive inclusion list to promote collection of relevant data. 104 real toxicology cases were analysed, and the results were cross-validated with one published and one commercial screening procedures. Quantitative MRM analyses were also performed on identified substances on a triple quadrupole instrument as a complementary confirmation procedure. The method showed limits of identification (LOIs) in appropriateness with therapeutic ranges for all the classes of interest. Applying the three screening approaches on 104 real cases, 271 identifications were performed including 14 and 6 classes of prescribed and illicit drugs, respectively. Among the detected substances, 23% were only detected by the proposed method. Based on confirmatory analyses, we demonstrated that the use of blood micro-samples did not impair the sensitivity allowing more identifications in the low concentration ranges. A LC-HRMS assay was successfully developed for toxicological screening of blood microsamples demonstrating a high identification power at low concentration ranges. The validation procedure and the analysis of real cases demonstrated the potential of this assay by supplementing screening approaches of reference
    corecore